§56.50-10. Special gauge requirements.

46 C.F.R. § 56.50-10

(a)
Where pressure-reducing valves are employed, a pressure gauge must be provided on the low-pressure side of the reducing station.
(b)
Fuel oil service and transfer, fire, cargo, and boiler feed pumps must be provided with a discharge pressure gage. Additional information pertaining to fire pumps is in § 34.10-5 of subchapter D, § 76.10-5 of subchapter H, § 95.10-5 of subchapter I, and § 108.417 of subchapter IA, all of this chapter.