§42.15-50. Air pipes.

46 C.F.R. § 42.15-50

(a)
Where air pipes to ballast and other tanks extend above the freeboard or superstructure decks, the exposed parts of the pipes shall be of substantial construction; the height from the deck to the point where water may have access below shall be at least 30 inches on the freeboard deck and 17 1/2 inches on the superstructure deck. Where these heights may interfere with the working of the vessel, a lower height may be approved, provided the assigning authority is satisfied that the closing arrangements and other circumstances justify a lower height. Satisfactory means permanently attached, shall be provided for closing the openings of the air pipes.
Notes, amendments, and revision history

Amendments

[CGFR 68-60, 33 FR 10062, July 12, 1968, as amended by CGFR 68-126, 34 FR 9014, June 5, 1969]

Authority

Authority: 46 U.S.C. 5101-5116; Department of Homeland Security Delegation No. 00170.1, Revision No. 01.4; section 42.01-5 also issued under the authority of 44 U.S.C. 3507.