§197.310. Air compressor system.
46 C.F.R. § 197.310
A compressor used to supply breathing air to a diver must have—
A volume tank that is—
Built and stamped in accordance with section VIII, division 1 of the ASME Code with—
A check valve on the inlet side;
A pressure gage;
A relief valve; and
A drain valve; and
Tested after every repair, modification, or alteration to the pressure boundaries as required by § 197.462;
Intakes that are located away from areas containing exhaust fumes of internal combustion engines or other hazardous contaminants;
An efficient filtration system; and
Slow-opening shut-off valves when the maximum allowable working pressure of the system exceeds 500 psig.
Notes, amendments, and revision history
Authority
Authority: 33 U.S.C. 1509; 43 U.S.C. 1333; 46 U.S.C. 3306, 3703, 6101; Department of Homeland Security Delegation No. 0170.1.
Source
Source: CGD 76-009, 43 FR 53683, Nov. 16, 1978, unless otherwise noted.