§182.440. Independent fuel tanks. — Inbound Citations

46 C.F.R. § 182.440

Cited by 3 regulations in release Current.

Citations to §182.440(a)

Citations to §182.440(a)(1)

  • (1) The material used and the minimum thickness allowed must be as indicated in Table 1 to § 182.440(a)(1), except that other materials that provide equivalent safety may be approved for use under paragraph (a)(3) of this section. Tanks having a capacity of more than 570 liters (150 gallons) must be designed to withstand the maximum head to which they may be subjected in service, but in no case may the thickness be less than that specified in Table 1 to § 182.440(a)(1).

Citations to §182.440(d)