§181.320. Fire hoses and nozzles. — Inbound Citations
46 C.F.R. § 181.320
Statutory Authority
Cited by 3 regulations in release Current.
Citations to 46 U.S.C. § 181.320 as a whole
-
(c) On a ferry vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, the minimum capacity of the fire pump must be 38 liters (10 gallons) per minute. The fire pump must be capable of projecting a hose stream from the highest hydrant, through the hose and nozzle required by § 181.320 of this part, a distance of 7.6 meters (25 feet).
Citations to §181.320(b)
-
(7) NFPA 1963-1989, Fire Hose Connections, 1989 Edition, IBR approved for § 181.320(b).
-
(d) Spanner wrenches must be provided where a 40 millimeter (1.5 inch) diameter firehose is required by § 181.320(b). Existing vessels as of July 22, 2016 have 180 days to comply with this requirement.