§171.070. Subdivision requirements—Type II.

46 C.F.R. § 171.070

(a)
Each vessel, except a ferry vessel, must be designed so that, while in each condition of loading and operation, it complies with the standard of flooding specified in Table 171.070(a).
(b)
Except as provided in paragraph (c), each ferry vessel must be designed so that, while in each condition of loading and operation, it meets the standard of flooding specified in Table 171.070(b).
(c)
A ferry vessel described in paragraph (d) of this section need not meet the standard of flooding specified in Table 171.070(b), except that a ferry vessel in Great Lakes service must at least have a collision bulkhead.
(d)
Paragraph (c) of this section applies to a ferry vessel that—
(1)
Is 150 feet (46 meters) or less in length; and
(2)
Has sufficient air tankage, or other internal buoyancy to float the vessel with no part of the margin line submerged when the vessel is completely flooded. If foam is used to comply with this paragraph, it must be installed in accordance with the requirements in § 170.245 of this subchapter.
(e)
Except as specified in paragraph (f) of this section, each main transverse watertight bulkhead must be spaced as follows:
(1)
Unless otherwise permitted, if the LBP of the vessel is 143 feet (43.5 meters) or more, or the vessel makes international voyages, each main transverse watertight bulkhead must be at least 10 feet (3 meters) plus 3 percent of the vessel's LBP from—
(i)
Every other main transverse watertight bulkhead;
(ii)
The collision bulkhead; and
(iii)
The aftermost point on the bulkhead deck.
(2)
If the LBP of the vessel is less than 143 feet (43.5 meters) and the vessel does not make international voyages, each main transverse watertight bulkhead must be no less than 10 percent of the vessel's LBP or 6 feet (1.8 meters), whichever is greater, from—
(i)
Every other main transverse watertight bulkhead;
(ii)
The collision bulkhead; and
(iii)
The aftermost point on the bulkhead deck.
(f)
If a vessel is required by § 171.060 to have a collision bulkhead in each end of the vessel, then each main transverse watertight bulkhead must be no less than the distance specified in paragraph (e) of this section from—
(1)
Every other main transverse watertight bulkhead; and
(2)
Each collision bulkhead.
Notes, amendments, and revision history

Amendments

[CGD 79-023, 48 FR 51017, Nov. 4, 1983, as amended by USCG-2007-0030, 75 FR 78085, Dec. 14, 2010; USCG-2014-0688, 79 FR 58287, Sept. 29, 2014]

Authority

Authority: 46 U.S.C. 2103, 3306; E.O. 12234, 45 FR 58801, 3 CFR, 1980 Comp., p. 277; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 79-023, 48 FR 51017, Nov. 4, 1983, unless otherwise noted.

Amendments

[CGD 79-023, 48 FR 51017, Nov. 4, 1983, as amended by USCG-2007-0030, 75 FR 78085, Dec. 14, 2010; USCG-2014-0688, 79 FR 58287, Sept. 29, 2014]

§171.072. Calculation of permeability for Type II subdivision.

46 C.F.R. § 171.072

When doing calculations to show compliance with § 171.070, the following uniform average permeabilities must be assumed:
(a)
85 percent in the machinery space.
(b)
60 percent in the following spaces:
(1)
Tanks that are normally filled when the vessel is in the full load condition.
(2)
Chain lockers.
(3)
Cargo spaces.
(4)
Stores spaces.
(5)
Mail or baggage spaces.
(c)
95 percent in all other spaces.
Notes, amendments, and revision history

Amendments

[CGD 79-023, 48 FR 51017, Nov. 4, 1983, as amended by USCG-2014-0688, 79 FR 58287, Sept. 29, 2014]

Authority

Authority: 46 U.S.C. 2103, 3306; E.O. 12234, 45 FR 58801, 3 CFR, 1980 Comp., p. 277; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 79-023, 48 FR 51017, Nov. 4, 1983, unless otherwise noted.

Amendments

[CGD 79-023, 48 FR 51017, Nov. 4, 1983, as amended by USCG-2014-0688, 79 FR 58287, Sept. 29, 2014]

§171.073. Treatment of stepped and recessed bulkheads in Type II subdivision.

46 C.F.R. § 171.073

(a)
A main transverse watertight bulkhead may not be stepped unless additional watertight bulkheads are located as shown in Figure 171.067(a) so that the distances A, B, C, and D illustrated in Figure 171.067(a) comply with the following:
(1)
A and B must not exceed the maximum bulkhead spacing that permits compliance with § 171.070; and
(2)
C and D must not be less than the minimum spacing specified in § 171.070(e).
(b)
A main transverse watertight bulkhead may not be recessed unless all parts of the recess are inboard from the shell of the vessel as illustrated in Figure 171.067(c).
(c)
If a main transverse watertight bulkhead is recessed or stepped, an equivalent plane bulkhead must be used in the calculations required by § 171.070.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 2103, 3306; E.O. 12234, 45 FR 58801, 3 CFR, 1980 Comp., p. 277; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 79-023, 48 FR 51017, Nov. 4, 1983, unless otherwise noted.