§170.173. Criterion for vessels of unusual proportion and form. — Inbound Citations
46 C.F.R. § 170.173
Statutory Authority
Cited by 12 regulations in release Current.
Citations to 46 U.S.C. § 170.173 as a whole
-
-
(b) A vessel not subject to the requirements of paragraph (a) of this section is permitted to comply with the applicable criteria contained in the 2008 IS Code as an alternative to the requirements of §§ 170.170 and 170.173 of this part.
-
(d) The criterion specified in this section is generally limited in application to the conditions of loading and operation of flush deck, mechanically powered vessels of ordinary proportions and form for which the righting arm (GZ) at the angle (T), calculated after the vessel is permitted to trim free until the trimming moment is zero, is not less than the minimum metacentric height (GM) calculated in paragraph (a) of this section multiplied by sin(T). On other types of vessels, the Coast Guard Marine Safety Center requires calculations in addition to those in paragraph (a) of this section. On a mechanically powered vessel under 328 feet (100 meters) in length, other than a tugboat or a towboat, the requirements in § 170.173 are applied.
-
(a) Each OSV must be shown by design calculations to meet, under each condition of loading and operation, the minimal requirements for metacentric height (GM) in § 170.170 of this chapter, and in either § 170.173 of this chapter or paragraphs (b) through (e) of this section.
-
-
-
Citations to §170.173(a)
-
(e) For the purpose of demonstrating acceptable stability on the vessels described in § 170.170(d) as having unusual proportion and form, compliance with paragraphs (a) through (d) of this section or the following criteria is required:(1) For partially protected routes, there must be—(i) Positive righting arms to at least 35 degrees of heel;(ii) No down flooding point to at least 20 degrees; and(C) 40 degrees.(2) For protected routes, there must be—(i) Positive righting arms to at least 25 degrees of heel;(ii) No down flooding point to at least 15 degrees; and(C) 40 degrees.
Citations to §170.173(b)
-
(e) For the purpose of demonstrating acceptable stability on the vessels described in § 170.170(d) as having unusual proportion and form, compliance with paragraphs (a) through (d) of this section or the following criteria is required:(1) For partially protected routes, there must be—(i) Positive righting arms to at least 35 degrees of heel;(ii) No down flooding point to at least 20 degrees; and(C) 40 degrees.(2) For protected routes, there must be—(i) Positive righting arms to at least 25 degrees of heel;(ii) No down flooding point to at least 15 degrees; and(C) 40 degrees.
Citations to §170.173(c)
-
(c) In lieu of meeting the requirements of paragraph (a) of this section, a vessel may comply with the provisions of § 170.173(c) of this chapter, provided that righting arms are positive to an angle of heel of not less than 50° (0.87 radians).
-
(e) For the purpose of demonstrating acceptable stability on the vessels described in § 170.170(d) as having unusual proportion and form, compliance with paragraphs (a) through (d) of this section or the following criteria is required:(1) For partially protected routes, there must be—(i) Positive righting arms to at least 35 degrees of heel;(ii) No down flooding point to at least 20 degrees; and(C) 40 degrees.(2) For protected routes, there must be—(i) Positive righting arms to at least 25 degrees of heel;(ii) No down flooding point to at least 15 degrees; and(C) 40 degrees.
Citations to §170.173(d)
-
(e) For the purpose of demonstrating acceptable stability on the vessels described in § 170.170(d) as having unusual proportion and form, compliance with paragraphs (a) through (d) of this section or the following criteria is required:(1) For partially protected routes, there must be—(i) Positive righting arms to at least 35 degrees of heel;(ii) No down flooding point to at least 20 degrees; and(C) 40 degrees.(2) For protected routes, there must be—(i) Positive righting arms to at least 25 degrees of heel;(ii) No down flooding point to at least 15 degrees; and(C) 40 degrees.