§169.690. Lighting branch circuits.

46 C.F.R. § 169.690

Each lighting branch circuit must meet the requirements of § 111.75-5 of this chapter, except that—
(a)
Appliance loads, electric heater loads, and isolated small motor loads may be connected to a lighting distribution panelboard; and
(b)
Branch circuits in excess of 30 amperes may be supplied from a lighting distribution panelboard.