US Codex
C.F.R.
Browse by date
Notes

§162.050-19. Oil content meter and bilge alarm test rig.

46 C.F.R. § 162.050-19

(a)
This section contains requirements for test rigs used in approval testing of oil content meters and meter. A typical test rig is described in Figure 162.050-19. The mixture pipe shown in Figure 162.050-19 is the portion of test rig piping between the oil injection point and the meter or bilge alarm piping.
(b)
Each sample point on a test rig must be of the type described in Figure 162.050-17(e) and must be in a vertical portion of the test rig piping.
(c)
Each test rig must have a centrifugal pump that is designed to operate at 1,000 revolutions per minute or more.
(d)
The mixture pipe on a test rig must have a uniform inside diameter.
Notes, amendments, and revision history

Amendments

[CGD 76-088a, 44 FR 53359, Sept. 13, 1979, as amended by USCG-2004-18939, 74 FR 3385, Jan. 16, 2009]

Source

Source: CGD 76-088a, 44 FR 53359, Sept. 13, 1979, unless otherwise noted.

Authority

Authority: 33 U.S.C. 1321(j), 1903; 46 U.S.C. 3306, 3703, 4104, 4302; E.O. 12234, 45 FR 58801, 3 CFR, 1980 Comp., p. 277; E.O. 12777, 56 FR 54757, 3 CFR, 1991 Comp., p. 351; DHS Delegation 00170.1, Revision No. 01.4.

Amendments

[CGD 76-088a, 44 FR 53359, Sept. 13, 1979, as amended by USCG-2004-18939, 74 FR 3385, Jan. 16, 2009]