US Codex
C.F.R.
Browse by date
Notes

§159.007-13. Production inspections and tests: Records. — Inbound Citations

46 C.F.R. § 159.007-13

Cited by 14 regulations in release Current.

Citations to 46 U.S.C. § 159.007-13 as a whole

  • (a) Each manufacturer of inflatable PFDs shall keep the records of production inspections and tests as required by § 159.007-13 of this chapter, except that they must be retained for at least 120 months after the month in which the inspection or test was conducted.
  • (c) The manufacturer must maintain records in accordance with 46 CFR 159.007-13. The manufacturer must keep records of all items listed in this section for at least 5 years from the date of termination of approval of each winch. The records must include—
    (1) A copy of this subpart, other CFR sections referenced in this subpart, and each document listed in § 160.115-5 of this subpart;
    (2) A copy of the approved plans, documentation, and certifications;
    (3) A current certificate of approval for each approved winch;
    (4) Affidavits, certificates, or invoices from the suppliers identifying all essential materials used in the production of approved winches, together with records identifying the serial numbers of the winches in which such materials were used;
    (5) Records of all structural welding and name of operator(s);
    (6) Records of welder certificates, training, and qualifications;
    (7) Date and results of calibration of test equipment and the name and address of the company or agency that performed the calibration;
    (8) The serial number of each production winch, along with records of its inspections and tests carried out under this section; and
  • (c) The manufacturer must maintain records in accordance with 46 CFR 159.007-13. The manufacturer must keep records of all items listed in this section for at least 5 years from the date of termination of approval of each davit. The records must include—
    (1) A copy of this subpart, other CFR sections referenced in this subpart, and each document listed in § 160.132-5 of this subpart;
    (2) A copy of the approved plans, documentation, and certifications;
    (3) A current certificate of approval for each approved davit;
    (4) Affidavits, certificates, or invoices from the suppliers identifying all essential materials used in the production of approved davits, together with records identifying the serial numbers of davits in which such materials were used;
    (5) Records of all structural welding and name of operator(s);
    (6) Records of welder certificates, training, and qualifications;
    (7) Date and results of calibration of test equipment and the name and address of the company or agency that performed the calibration;
    (8) The serial number of each production davit, along with records of its inspections and tests carried out under this section; and
  • (c) The manufacturer must maintain records in accordance with 46 CFR 159.007-13. The manufacturer must keep records of all items listed in this section for at least 5 years from the date of termination of approval of each release mechanism. The records must include—
    (1) A copy of this subpart, other CFR sections referenced in this subpart, and each document listed in § 160.133-5 of this subpart;
    (2) A copy of the approved plans, documentation, and certifications;
    (3) A current certificate of approval for each approved release mechanism;
    (4) Affidavits, certificates, or invoices from the suppliers identifying all essential materials used in the production of approved release mechanisms, together with records identifying the serial numbers of the release mechanisms in which such materials were used;
    (5) Records of all structural welding and name of operator(s);
    (6) Records of welder certificates, training, and qualifications;
    (7) Date and results of calibration of test equipment and the name and address of the company or agency that performed the calibration;
    (8) The serial number of each production release mechanism, along with records of its inspections and tests carried out under this section; and
  • (c) The manufacturer must maintain records in accordance with 46 CFR 159.007-13. The manufacturer must keep records of all items listed in this section for at least 5 years from the date of termination of approval of each lifeboat. The records must include—
    (1) A copy of this subpart, other CFR sections referenced in this subpart, and each applicable document listed in § 160.135-5 of this subpart;
    (2) A copy of approved plans, documentation, and certifications;
    (3) A current certificate of approval for each approved lifeboat;
    (4) Affidavits, certificates, or invoices from the suppliers identifying all essential materials used in the production of approved lifeboats, together with records identifying the serial numbers of the lifeboats in which such materials were used;
    (5) Start and finish date and time of the lay-up of each major Fiber Reinforced Plastic (FRP) component such as the hull, canopy, and inner liner and the names of the operator(s);
    (6) Start and finish date and time of pouring of foam-in-place rigid buoyancy foam, and name of operator(s);
    (7) Records of all structural welding and name of operator(s);
    (8) Records of welder certificates, training and qualifications;
    (9) Date and results of calibration of test equipment and the name and address of the company or agency that performed the calibration;
    (10) The serial number of each production lifeboat, along with records of its inspections and tests carried out under this section; and
  • (c) Among the records required to be retained by the manufacturer under 46 CFR 159.007-13 , are affidavits or invoices from the suppliers identifying all essential materials used in the production of approved liferafts, together with the lot numbers of the liferafts constructed with those materials.
  • (c) The manufacturer must maintain records in accordance with 46 CFR 159.007-13. The manufacturer must keep records of all items listed in this section for at least 5 years from the date of termination of approval of each rescue boat. The records must include—
    (1) A copy of this subpart, other CFR sections referenced in this subpart, and each applicable document listed in § 160.156-5 of this subpart;
    (2) A copy of approved plans, documentation, and certifications;
    (3) A current certificate of approval for each approved rescue boat;
    (4) Affidavits, certificates, or invoices from the suppliers identifying all essential materials used in the production of approved rescue boats, together with records identifying the serial numbers of the rescue boats in which such materials were used;
    (5) Start and finish date and time of the lay-up of each major Fiber Reinforced Plastic (FRP) component such as the hull, canopy, and inner liner and the names of the operator(s);
    (6) Start and finish date and time of pouring of foam-in-place rigid buoyancy foam, and name of operator(s);
    (7) Records of all structural welding and name of operator(s);
    (8) Records of welder certificates, training and qualifications;
    (9) Date and results of calibration of test equipment and the name and address of the company or agency that performed the calibration;
    (10) The serial number of each production rescue boat, along with records of its inspections and test carried out under this section; and
  • (c) The manufacturer must maintain records in accordance with 46 CFR 159.007-13. The manufacturer must keep records of all items listed in this section for at least 5 years from the date of termination of approval of each release mechanism. The records must include—
    (1) A copy of this subpart, other CFR sections referenced in this subpart, and each document listed in § 160.170-5 of this subpart;
    (2) A copy of the approved plans and documentation;
    (3) A current certificate of approval for each approved release mechanism;
    (4) Affidavits, certificates, or invoices from the suppliers identifying all essential materials used in the production of approved release mechanisms, together with records identifying the serial numbers of the release mechanisms in which such materials were used;
    (5) Records of all structural welding and name of operator(s);
    (6) Records of welder certificates, training, and qualifications;
    (7) Date and results of calibration of test equipment and the name and address of the company or agency that performed the calibration;
    (8) The serial number of each production release gear, along with records of its inspections and tests carried out under this section; and
  • (a) Each manufacturer of inflatable lifejackets must keep the records required by § 159.007-13 of this chapter except that they must be retained for at least 120 months after the month in which the inspection or test was conducted.
  • (a) The system must be inspected in accordance with this section and 46 CFR 159.007-1 through 159.007-13, and tested using any additional tests that the Commandant (CG-5214) may deem necessary to maintain control of quality and to ensure compliance with this subpart.
  • (a) Each component manufacturer shall retain records as required by § 159.007-13 of this chapter.

Citations to §159.007-13(a)

  • (3) This examination must be done by a manufacturer's representative who is familiar with the approved plans and specifications required by § 160.176-5(a)(2) of this part, the functioning of the lifejacket and its components, and the production testing procedures. This person must not be responsible for meeting production schedules or be supervised by someone who is. This person must prepare and sign the record required by § 159.007-13(a) of this chapter and § 160.176-17(b) of this part.

Citations to §159.007-13(a)(4)