§154.906. Inert gas generators.
46 C.F.R. § 154.906
The inert gas generator must:
Produce an inert gas containing less than 5% oxygen by volume;
Have a device to continuously sample the discharge of the generator for oxygen content; and
Have an audible and visual alarm in the cargo control station that alarms when the inert gas contains 5% or more oxygen by volume.