US Codex
C.F.R.
Browse by date
Notes

§154.906. Inert gas generators.

46 C.F.R. § 154.906

The inert gas generator must:
(a)
Produce an inert gas containing less than 5% oxygen by volume;
(b)
Have a device to continuously sample the discharge of the generator for oxygen content; and
(c)
Have an audible and visual alarm in the cargo control station that alarms when the inert gas contains 5% or more oxygen by volume.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.