§154.706. Cargo boil-off as fuel: Fuel lines. — Inbound Citations
46 C.F.R. § 154.706
Statutory Authority
Cited by 11 regulations in release Current.
Citations to 46 U.S.C. § 154.706 as a whole
-
(17) Section 154.706.
-
(6) If the vessel carries methane, a description of the systems for cargo temperature and pressure control. (See §§ 154.703 through 154.709).
-
When the vessel is on the navigable waters of the United States, the master shall ensure that the cargo pressure and temperature control system under §§ 154.701 through 154.709 is operating and that venting of cargo is unnecessary to maintain cargo temperature and pressure control, except under emergency conditions.
-
(a) Each cargo boil-off fuel system under § 154.703(c) must meet §§ 154.706 through 154.709.
Citations to §154.706(a)(1)
-
(d) The master shall ensure that the oxygen concentration in the annular space of the fuel line under § 154.706(a)(1) is 8% or less by volume before methane (LNG) vapors are admitted to the fuel line.
-
(3) Loss of inert gas pressure within the double-walled piping system under § 154.706(a)(1).
Citations to §154.706(a)(2)
-
(1) A gas leak detected under § 154.706(a)(2) or § 154.706(b);
-
(a) The continuous gas detection system required under § 154.706(a)(2) and (b) must:(1) Meet § 154.1350(c), (d), and (j) through (s); and(i) Activates an audible and visual alarm at the machinery control station and in the wheelhouse if the methane concentration reaches 1.5 percent by volume; and(ii) Closes the master gas fuel valve required under § 154.708(c) before the methane concentration reaches 3 percent by volume.
Citations to §154.706(a)(b)
-
(a) The continuous gas detection system required under § 154.706(a)(2) and (b) must:(1) Meet § 154.1350(c), (d), and (j) through (s); and(i) Activates an audible and visual alarm at the machinery control station and in the wheelhouse if the methane concentration reaches 1.5 percent by volume; and(ii) Closes the master gas fuel valve required under § 154.708(c) before the methane concentration reaches 3 percent by volume.
Citations to §154.706(b)
-
(1) A gas leak detected under § 154.706(a)(2) or § 154.706(b);
-
(a) The continuous gas detection system required under § 154.706(a)(2) and (b) must:(1) Meet § 154.1350(c), (d), and (j) through (s); and(i) Activates an audible and visual alarm at the machinery control station and in the wheelhouse if the methane concentration reaches 1.5 percent by volume; and(ii) Closes the master gas fuel valve required under § 154.708(c) before the methane concentration reaches 3 percent by volume.