§154.315. Cargo pump and cargo compressor rooms.

46 C.F.R. § 154.315

(a)
Cargo pump rooms and cargo compressor rooms must be above the weather deck and must be within the cargo area.
(b)
Where pumps and compressors are driven by a prime mover in an adjacent gas safe space:
(1)
The bulkhead or deck must be gastight; and
(2)
The shafting passing through the bulkhead or deck must be sealed by a fixed oil reservoir gland seal, a pressure grease seal, or another type of positive pressure seal specially approved by the Commandant (CG-ENG).