§154.172. Contiguous steel hull structure. — Inbound Citations
46 C.F.R. § 154.172
Statutory Authority
Cited by 4 regulations in release Current.
Citations to 46 U.S.C. § 154.172 as a whole
-
(4) Each device must actuate an audible and visual alarm at the cargo control station and a remote group alarm in the wheelhouse before the temperature of the steel of the adjacent hull structure is cooled below the lowest temperature allowed for the steel under § 154.172.
-
(3) The outer hull steel of vessels must meet the standards in § 154.172 if the hull steel temperature is calculated to be below −5 °C (23 °F) assuming:(i) For any waters in the world, the ambient cold conditions of still air at 5 °C (41 °F) and still sea water at 0 °C (32 °F);(ii) For cargo containment systems with secondary barriers, the temperature of the secondary barrier is the design temperature; and(iii) For cargo containment systems without secondary barriers, the temperature of the cargo tank is the design temperature.
-
-
If the design temperature is below −10 °C (14 °F), the cargo tank insulation must prevent the temperature of the vessel's hull from cooling below the minimum temperature allowed under § 154.172.