US Codex
C.F.R.
Browse by date
Notes

§153.554. Special requirements for acids.

46 C.F.R. § 153.554

When Table 1 refers to this section:
(a)
Each containment system loading and discharge connection must have a spray shield;
(b)
Each cargo containment system must be separated from bunkers by double walls, such as a cofferdam and piping tunnels; and
(c)
Each vessel must have on board a means to determine whether cargo has leaked into the spaces adjacent to a cargo containment system.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703; Department of Homeland Security Delegation No. 0170.1. Section 153.40 issued under 49 U.S.C. 5103. Sections 153.470 through 153.491, 153.1100 through 153.1132, and 153.1600 through 153.1608 also issued under 33 U.S.C. 1903 (b).

Source

Source: CGD 73-96, 42 FR 49027, Sept. 26, 1977, unless otherwise noted.