§153.406. Standards for containment systems having required restricted gauges.
46 C.F.R. § 153.406
When Table 1 requires a cargo's containment system to have a restricted gauge, the containment system must have:
A closed gauging system; or
A system that has—
A restricted gauge (e.g., a sounding tube) with an orifice diameter not exceeding 20 cm (approx. 7.8 in.);
A permanently attached gauge cover that is vapor tight when in place; and
A venting system that has either—
Lock open PV valves; or
Valved bypasses around the PV valves.