§153.231. Type II system. — Inbound Citations
46 C.F.R. § 153.231
Statutory Authority
Cited by 2 regulations in release Current.
Citations to §153.231(b)
-
Cargo piping must not be located in those areas from which a containment system is excluded by §§ 153.230(b), 153.231(b), and 153.234(b) unless the cargo piping:
-
(3) The Commandant (CG-ENG) considers on a case by case basis endorsing as a type II containment system one that fails to meet §§ 153.231(b), 153.234, 172.130 and 172.133 of this chapter if the tankship and containment system meet the following minimum conditions:(iii) The distance between the bottom plating of the cargo tank and the bottom shell plating of the tankship is at least 76 cm measured parallel to the vertical axis of the tankship.