§150.130. Loading a cargo on vessels carrying cargoes with which it is incompatible.

46 C.F.R. § 150.130

Except as described in § 150.160, the person in charge of a vessel shall ensure that the containment system for a cargo that is a hazardous material meets the following requirements:
(a)
The containment system must separate the hazardous material or its residue from any cargo in table 1 with which it is incompatible by two barriers such as formed by a:
(1)
Cofferdam;
(2)
Empty tank;
(3)
Void space;
(4)
Cargo handling space;
(5)
Tank containing a compatible cargo; or
(6)
Piping tunnel.
(b)
In this subpart, isolation across a cruciform joint is equivalent to isolation by two barriers.
(c)
The containment system for the hazardous material must not have a piping or venting system that connects to a containment system carrying a cargo with which the hazardous material is incompatible. Any such piping or venting system must have been separated from the containment system carrying the incompatible cargo by:
(1)
Removing a valve or spool piece and blanking off the exposed pipe ends, or
(2)
Installing two spectacle flanges in series with a means of detecting leakage into the pipe between the spectacle flanges.
Notes, amendments, and revision history

Amendments

[CGD 75-59, 45 FR 70263, Oct. 23, 1980, as amended at USCG-2013-0423, 85 FR 21674, Apr. 17, 2020]

Authority

Authority: 46 U.S.C. 3306, 3703; DHS Delegation No. 00170.1, Revision No. 01.3.

Source

Source: CGD 75-59, 45 FR 70263, Oct. 23, 1980, unless otherwise noted.

Amendments

[CGD 75-59, 45 FR 70263, Oct. 23, 1980, as amended at USCG-2013-0423, 85 FR 21674, Apr. 17, 2020]