§148.405. Sources of ignition.
46 C.F.R. § 148.405
Except in an emergency, no welding, burning, cutting, chipping, or other operations involving the use of fire, open flame, sparks, or arc-producing equipment, may be performed in a cargo hold containing a Table 148.10 material or in an adjacent space.
A cargo hold or adjacent space must not have any flammable gas concentrations over 10 percent of the LFL before the master may approve operations involving the use of fire, open flame, or spark- or arc-producing equipment in that hold or adjacent space.
Notes, amendments, and revision history
Authority
Authority: 33 U.S.C. 1602; E.O. 12234, 45 FR 58801, 3 CFR, 1980 Comp., p. 277; 46 U.S.C. 3306, 5111; 49 U.S.C. 5103; Department of Homeland Security Delegation No. 0170.1.
Source
Source: 75 FR 64591, Oct. 19, 2010, unless otherwise noted.