US Codex
C.F.R.
Browse by date
Notes

§136.112. Incorporation by reference. — Inbound Citations

46 C.F.R. § 136.112

Cited by 29 regulations in release Current.

Citations to 46 C.F.R. § 136.112 as a whole

  • (3) Sitting area;
  • (b) The Coast Guard may accept compliance with the provisions of SOLAS applicable to the vessel's size and route (incorporated by reference, see § 136.112), as an equivalent to specific requirements of this subchapter. Submit requests for a determination of equivalency for a particular vessel to the Coast Guard via the cognizant OCMI.
  • (2) 2008(E) (incorporated by reference, see § 136.112 of this subchapter) internal auditor/assessor course or Coast Guard-recognized equivalent;
  • (d) Objective evidence of an internal quality system based on ANSI/ISO/ASQ Q9001-2000 (incorporated by reference, see § 136.112 of this subchapter) or an equivalent quality standard.
  • (3) 2008(E) (incorporated by reference, see § 136.112 of this subchapter) lead auditor/assessor course or Coast Guard recognized equivalent.
  • (a) The inspections and issuance of certificates required by this section must be conducted in accordance with the provisions of NFPA 306 (incorporated by reference, see § 136.112 of this subchapter) before alterations, repairs, or other operations involving riveting, welding, burning, or other fire producing actions may be made aboard a vessel.
  • (b) A towing vessel on an international voyage, subject to SOLAS (incorporated by reference, see § 136.112 of this subchapter), must meet the applicable requirements in subchapter W of this chapter.
  • (c) The Coast Guard may approve a novel lifesaving appliance or arrangement as an equivalent if it has performance characteristics at least equivalent to the appliance or arrangement required under this subchapter, and if it has been evaluated and tested under IMO Resolution A.520(13) (incorporated by reference, see § 136.112 of this subchapter). Requests for evaluation of novel lifesaving appliances must be sent to the Commandant (CG-ENG).
  • (2) With Type I retro-reflective material approved under approval series 164.018. The arrangement of the retro-reflective material must meet IMO Resolution A.658(16) (incorporated by reference, see § 136.112 of this subchapter).
  • (a) Towing vessels in compliance with Chapter II-2 of SOLAS (incorporated by reference, see § 136.112 of this subchapter) will be deemed to be in compliance with this part.
  • (1) A flammable liquid storage cabinet that satisfies UL 1275 (incorporated by reference, see § 136.112 of this subchapter); or
  • (a) At least two firefighter's outfits that meet NFPA 1971 (incorporated by reference, see § 136.112 of this subchapter); and
  • (1) Portable and semi-portable fire extinguishers must be inspected, maintained, and tested in accordance with the inspection, maintenance procedures, and hydrostatic pressure tests required by Chapters 7 and 8 of NFPA 10, Standard for Portable Fire Extinguishers (incorporated by reference, see § 136.112 of this subchapter), with the frequency specified by NFPA 10 and as amended here:
    (i) Certification or licensing by a state or local jurisdiction as a fire extinguisher servicing agency will be accepted by the Coast Guard as meeting the personnel certification requirements of NFPA 10 for annual maintenance and recharging of extinguishers.
    (ii) Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew.
    (iii) Non-rechargeable or non-refillable extinguishers must be inspected and maintained in accordance with NFPA 10; however, the annual maintenance need not be conducted by a certified person and can be conducted by the owner, operator, person-in-charge, or a designated member of the crew.
    (iv) The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector or TPO, as applicable. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests. A tag issued by a qualified servicing organization, and attached to each extinguisher, may be accepted as evidence that the necessary maintenance procedures have been conducted.
  • (b) Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. This may be accomplished by an installed detection system, or by using individual battery-operated detectors meeting UL 217 (incorporated by reference, see § 136.112 of this subchapter). Detection systems or individual detectors must be kept operational at all times when the crew is onboard the towing vessel.
  • (e) Color coding required by this section may be met by complying with coding standards contained in the ISO 14726:2008(E) (incorporated by reference, see § 136.112 of this subchapter), or in accordance with the TSMS applicable to the vessel.
  • (b) The vessel must not incorporate or carry portable fuel systems, including portable tanks and related fuel lines and accessories, except when used for outboard engines or portable bilge or fire pumps. The design, construction, and stowage of portable tanks and related fuel lines and accessories must comply with the ABYC H-25 (incorporated by reference, see § 136.112 of this subchapter).
  • (a) Towing vessels more than 65 feet in length must use navigation lights that meet UL 1104 (incorporated by reference, see § 136.112 of this subchapter) or other standards accepted by the Coast Guard.
  • (a) Except as noted in paragraph (c) of this section, a towing vessel classed by the American Bureau of Shipping (ABS), in accordance with the ABS Rules for Building and Classing Steel Vessels Under 90 Meters (295 Feet) in Length, or the ABS Rules for Building and Classing Steel Vessels for Service on Rivers and Intracoastal Waterways (incorporated by reference, see § 136.112 of this subchapter), as appropriate for the intended service and routes, complies with this subpart.
  • (a) Except as noted in paragraphs (b) and (c) of this section, a new towing vessel 65 feet (19.8 meters) or less in length built to conform with the American Boat and Yacht Council (ABYC) standards listed in this paragraph (a) (incorporated by reference, see § 136.112 of this subchapter), complies with this subpart:
    (1) AC & DC Electrical Systems on Boats;
    (2) Ventilation of Boats Using Gasoline;
    (2) Electric Bilge Pump Systems;
    (3) Gasoline Fuel Systems;
    (4) Portable Gasoline Fuel Systems;
    (5) Ventilation of Boats Using Diesel Fuel;
    (6) Diesel Fuel Systems;
    (7) Installation of Exhaust Systems for Propulsion and Auxiliary Engines; and
    (8) Marine Inboard Engines and Transmissions.
  • (a) Pumps, pipes, valves, and fittings in essential systems on vessels must meet ABS Rules for Building and Classing Steel Vessels Under 90 Meters (295 Feet) in Length (incorporated by reference, see § 136.112 of this subchapter), Part 4, Chapter 4.
  • (b) Pressure vessels over 5 cubic feet in volume and more than 15 psi maximum allowable working pressure must meet ABS Rules for Building and Classing Steel Vessels under 90 Meters (295 Feet) in Length (incorporated by reference, see § 136.112 of this subchapter), Part 4, Chapter 1, Section 1.
  • (a) Steering systems must meet ABS Rules for Building and Classing Steel Vessels under 90 Meters (295 Feet) in Length (incorporated by reference, see § 136.112 of this subchapter), Part 4, Chapter 3, Section 3.
  • (4) Motors must be provided with overcurrent protection that meets Parts I through VII, Article 430 of NFPA's National Electrical Code (NEC) (incorporated by reference, see § 136.112 of this subchapter). Steering motor circuits must be protected as per Part 4 Chapter 6 Section 2, Regulation 11 (except 11.7) ofABS Rules for Building and Classing Steel Vessels Under 90 Meters (295 feet) in Length (incorporated by reference, see § 136.112 of this subchapter).
  • (1) Cable and wiring used in power and lighting circuits must have overcurrent protection that opens the circuit at the standard setting closest to 80 percent of the manufacturer's listed ampacity. Overcurrent protection setting exceptions allowed by NFPA's National Electrical Code (NEC), Article 240 (incorporated by reference, see § 136.112 of this subchapter) may be employed.
  • (a) ABS Rules for Building and Classing Steel Vessels Under 90 Meters (295 Feet) in Length (incorporated by reference, see § 136.112 of this subchapter), Part 4, Chapter 6; or
  • In lieu of meeting §§ 143.585 through 143.595, a towing vessel may comply with Sections 7-5 (class ABCU) and 3-5 (class R2) of Part 4 of the ABS Rules for Building and Classing Steel Vessels Under 90 Meters (295 Feet) in Length (incorporated by reference, see § 136.112 of this subchapter), except that a vessel that operates exclusively on rivers or intracoastal waterways does not need to comply with 4-7-4/3.9 and the automatic day tank fill pump requirement of 4-7-4/25.3.
  • Internal combustion engine exhaust ducts, galley exhaust ducts and similar ignition sources must be insulated with noncombustible insulation if less than 450 mm (18 inches) away from combustible material. Installations in accordance with ABYC P-1 or NFPA 302 (incorporated by reference, see § 136.112 of this subchapter) will be considered as meeting the requirements of this section.
  • (b) IMO Resolution A.688(17) (incorporated by reference, see § 136.112 of this subchapter) in which case the mattress may contain polyurethane foam.
  • (e) In a new vessel, glass or other glazing material used in windows at the operating station must have a light transmission of not less than 70 percent according to Test 2 of ANSI/SAE Z 26.1-1996 (incorporated by reference, see § 136.112 of this subchapter) and must comply with Test 15 of ANSI/SAE Z 26.1-1996 for Class I Optical Deviation.