§129.326. Dual-voltage generators.

46 C.F.R. § 129.326

If a dual-voltage generator is installed on an OSV—
(a)
The neutral of the dual-voltage system must be solidly grounded at the switchboard's neutral bus and be accessible for checking the insulation resistance of the generator; and
(b)
Ground detection must be provided that—
(1)
For an alternating-current system, complies with § 111.05-27 of this chapter; and
(2)
For a direct-current system, complies with § 111.05-29 of this chapter.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3306; sec. 617, Pub. L. 111-281, 124 Stat. 2905; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 82-004 and CGD 86-074, 62 FR 49332, Sept. 19, 1997, unless otherwise noted.