§128.430. Non-integral keel cooler installations.
46 C.F.R. § 128.430
Each hull penetration for a non-integral keel cooler installation must be made through a cofferdam or at a seachest and must be provided with isolation valves fitted as close to the sea inlet as possible.
Each non-integral keel cooler must be protected against damage from debris and grounding by protective guards or by recessing the cooler into the hull.