§120.340. Cable and wiring requirements. — Inbound Citations
46 C.F.R. § 120.340
Statutory Authority
Cited by 4 regulations in release Current.
Citations to §120.340(d)
-
(ii) Section 310-13, IBR approved for § 120.340(d),
Citations to §120.340(i)
-
(3) NFPA 17-1994, Dry Chemical Extinguishing Systems, 1994 Edition, IBR approved for § 118.425(b).
Citations to §120.340(o)
-
(1) Recommended Practice for Electrical Installations on Shipboard, IBR approved for § 120.340(o).
Citations to §120.340(p)
-
(p) Conductors must be sized so that the voltage drop at the load terminals does not exceed 10 percent. Table 1 to § 120.340(p) indicates the size of conductor required for corresponding lengths and steady state (stable) values to obtain not more than this voltage drop at the load terminals of a two conductor circuit.Other values can be computed by means of the following formula: