§119.530. Bilge high level alarms.

46 C.F.R. § 119.530

(a)
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in each of the following normally unmanned spaces:
(1)
A space with a through-hull fitting below the deepest load waterline, such as a lazarette;
(2)
A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and
(3)
A space with a non-watertight closure , such as a space with a non-watertight hatch on the main deck.
(b)
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating.