§119.470. Ventilation of spaces containing diesel fuel tanks.

46 C.F.R. § 119.470

(a)
Unless provided with ventilation that complies with § 119.465 of this part, a space containing a diesel fuel tank and no machinery must meet one of the following requirements:
(1)
A space of 14 cubic meters (500 cubic feet) or more in volume must have a gooseneck vent of not less than 65 millimeters (2.5 inches) in diameter; or
(2)
A space of less than 14 cubic meters (500 cubic feet) in volume must have a gooseneck vent of not less than 40 millimeters (1.5 inches) in diameter.
(b)
Vent openings may not be located adjacent to possible sources of vapor ignition.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 2103, 3306; E.O. 12234, 45 FR 58801, 3 CFR, 1980 Comp., p. 277; DHS Delegation No. 00170.1, Revision No. 01.3.

Source

Source: CGD 85-080, 61 FR 922, Jan. 10, 1996, unless otherwise noted.