US Codex
C.F.R.
Browse by date
Notes

§119.435. Integral fuel tanks.

46 C.F.R. § 119.435

(a)
Diesel fuel tanks may not be built integral with the hull of a vessel unless the hull is made of steel or aluminum.
(b)
During the initial inspection for certification of a vessel, integral fuel tanks must withstand a hydrostatic pressure test of 35 kPa (5 psig), or the maximum pressure head to which they may be subjected in service, whichever is greater. A standpipe of 3.5 meters (11.5 feet) in height attached to the tank may be filled with water to accomplish the 35 kPa (5 psig) test.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 2103, 3306; E.O. 12234, 45 FR 58801, 3 CFR, 1980 Comp., p. 277; DHS Delegation No. 00170.1, Revision No. 01.3.

Source

Source: CGD 85-080, 61 FR 922, Jan. 10, 1996, unless otherwise noted.