§116.600. Ventilation of enclosed and partially enclosed spaces.
46 C.F.R. § 116.600
An enclosed or partially enclosed space within a vessel must be adequately ventilated in a manner suitable for the purpose of the space.
A power ventilation system must be capable of being shut down from the pilot house.
An enclosed passenger or crew accommodation space and any other space occupied by a crew member on a regular basis must be ventilated by a power ventilation system unless natural ventilation in all ordinary weather conditions is satisfactory to the OCMI.
An exhaust duct over a frying vat or a grill must be at least 11 U.S. Standard Gauge (USSG) steel.