§116.600. Ventilation of enclosed and partially enclosed spaces.

46 C.F.R. § 116.600

(a)
An enclosed or partially enclosed space within a vessel must be adequately ventilated in a manner suitable for the purpose of the space.
(b)
A power ventilation system must be capable of being shut down from the pilot house.
(c)
An enclosed passenger or crew accommodation space and any other space occupied by a crew member on a regular basis must be ventilated by a power ventilation system unless natural ventilation in all ordinary weather conditions is satisfactory to the OCMI.
(d)
An exhaust duct over a frying vat or a grill must be at least 11 U.S. Standard Gauge (USSG) steel.
Notes, amendments, and revision history

Amendments

[CGD 85-080, 61 FR 900, Jan. 10, 1996, as amended at 62 FR 51350, Sept. 30, 1997]

Authority

Authority: 46 U.S.C. 2103, 3306; E.O. 12234, 45 FR 58801, 3 CFR, 1980 Comp., p. 277, DHS Delegation 00170.1, Revision No. 01.4.