§115.806. Electrical.

46 C.F.R. § 115.806

At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of electrical equipment and systems, including the following:
(a)
Inspection of all cable as far as practicable without undue disturbance of the cable or electrical apparatus;
(b)
Test of circuit breakers by manual operation;
(c)
Inspection of fuses including ensuring the ratings of fuses are suitable for the service intended;
(d)
Inspection of rotating electrical machinery essential to the routine operation of the vessel;
(e)
Inspection of all generators, motors, lighting fixtures and circuit interrupting devices located in spaces or areas that may contain flammable vapors;
(f)
Inspection of batteries for condition and security of stowage;
(g)
Operational test of electrical apparatus, which operates as part of or in conjunction with a fire detection or alarm system installed on board the vessel, by simulating, as closely as practicable, the actual operation in case of fire; and
(h)
Operational test of all emergency electrical systems.