§111.60-4. Minimum cable conductor size.
46 C.F.R. § 111.60-4
Each cable conductor must be 18 AWG (0.82 mm 2) or larger except—
Each power and lighting cable conductor must be 14 AWG (2.10 mm 2) or larger; and
Each thermocouple, pyrometer, or instrumentation cable conductor must be 22 AWG (0.33 mm 2) or larger.
Notes, amendments, and revision history
Amendments
[CGD 94-108, 61 FR 28280, June 4, 1996, as amended by USCG-2020-0075, 88 FR 16363, Mar. 16, 2023]
Authority
Authority: 46 U.S.C. 3306, 3703; DHS Delegation No. 00170.1, Revision No. 01.2. Section 111.05-20 and Subpart 111.106 also issued under sec. 617, Pub. L. 111-281, 124 Stat. 2905.
Source
Source: CGD 74-125A, 47 FR 15236, Apr. 8, 1982, unless otherwise noted.
Amendments