§111.60-11. Wire.
46 C.F.R. § 111.60-11
Wire must be in an enclosure.
Wire must be component insulated.
Wire, other than in switchboards, must meet the requirements in ANSI/UL 44, ANSI/UL 83, MIL-DTL-76E (all three standards incorporated by reference; see § 110.10-1 of this subchapter), or equivalent standard.
Switchboard wire must meet subpart 111.30 of this part.
Wire must be of the copper stranded type.