§111.15-2. Battery construction.
46 C.F.R. § 111.15-2
A battery cell, when inclined at 40 degrees from the vertical, must not spill electrolyte.
Each fully charged lead-acid battery must have a specific gravity that meets Section 11 of IEEE 45.1-2017 (incorporated by reference; see § 110.10-1 of this subchapter).
Batteries must not evolve hydrogen at a rate exceeding that of a similar size lead-acid battery under similar charging condition.
Batteries must be constructed to take into account the environmental conditions of a marine installation, including temperature, vibration, and shock.
Notes, amendments, and revision history
Amendments
[CGD 94-108, 61 FR 28277, June 4, 1996, as amended by USCG-2003-16630, 73 FR 65196, Oct. 31, 2008; USCG-2020-0075, 88 FR 16361, Mar. 16, 2023]
Authority
Authority: 46 U.S.C. 3306, 3703; DHS Delegation No. 00170.1, Revision No. 01.2. Section 111.05-20 and Subpart 111.106 also issued under sec. 617, Pub. L. 111-281, 124 Stat. 2905.
Source
Source: CGD 74-125A, 47 FR 15236, Apr. 8, 1982, unless otherwise noted.
Amendments
[CGD 94-108, 61 FR 28277, June 4, 1996, as amended by USCG-2003-16630, 73 FR 65196, Oct. 31, 2008; USCG-2020-0075, 88 FR 16361, Mar. 16, 2023]