§111.103-7. Ventilation stop stations.
46 C.F.R. § 111.103-7
Each power ventilation system stop station must:
Be protected by an enclosure with a glass-paneled door on the front;
Be marked, “In Case of Fire Break Glass and Operate Switch to Stop Ventilation;”
Have the “stop” position of the switch clearly identified;
Have a nameplate that identifies the system controlled; and
Be arranged so that damage to the switch or cable automatically stops the equipment controlled.