§111.05-23. Location of ground indicators.

46 C.F.R. § 111.05-23

Ground indicators must:
(a)
Be at the vessel's ship's service generator distribution switchboard for the normal power, normal lighting, and emergency lighting systems;
(b)
Be at the propulsion switchboard for propulsion systems; and
(c)
Be readily accessible.
(d)
Be provided (at the distribution switchboard or at another location, such as a centralized monitoring position for the circuit affected) for each feeder circuit that is isolated from the main source by a transformer or other device.