US Codex
C.F.R.
Browse by date
Notes

§108.597. Line-throwing appliance.

46 C.F.R. § 108.597

(a)
General. Each unit in international service must have a line-throwing appliance that is approved under approval series 160.040. Each unit not in international service must carry a line-throwing appliance approved under either approval series 160.040 or 160.031.
(b)
Stowage. The line-throwing appliance and its equipment must be readily accessible for use.
(c)
Additional equipment. Each unit must carry the following equipment for the line-throwing appliance:
(1)
The equipment on the list provided by the manufacturer with the approved appliance; and
(2)
An auxiliary line that—
(i)
Has a breaking strength of at least 40 kiloNewtons (9,000 pounds-force);
(ii)
Is, if synthetic, a dark color or certified by the manufacturer to be resistant to deterioration from ultraviolet light; and
(iii)
Is—
(A)
At least 450 meters (1,500 feet) long, if the line-throwing appliance is approved under approval series 160.040; or
(B)
At least 150 meters (500 feet) long, if the line-throwing appliance is approved under approval series 160.031.
Notes, amendments, and revision history

Source

Source: CGD 84-069, 61 FR 25291, May 20, 1996, unless otherwise noted.

Authority

Authority: 43 U.S.C. 1333; 46 U.S.C. 3102, 3306; DHS Delegation No. 00170.1, Revision No. 01.4.