US Codex
C.F.R.
Browse by date
Notes

§3175.93. Integration statements.

43 C.F.R. § 3175.93

An unedited integration statement must be retained and made available to the BLM upon request. The integration statement must contain the following information:
(a)
The information required in § 3170.7(g) of this part;
(b)
The name of the company performing the integration;
(c)
The month and year for which the integration statement applies;
(d)
Meter-tube inside diameter (inches);
(e)
The following primary device information, as applicable—
(i)
Orifice bore diameter (inches); or
(ii)
Beta or area ratio, discharge coefficient, and other information necessary to calculate the flow rate;
(f)
Relative density (specific gravity);
(g)
CO2 content (mole percent);
(h)
N2 content (mole percent);
(i)
Heating value calculated under § 3175.125 (Btu/standard cubic feet);
(j)
Atmospheric pressure or elevation at the FMP;
(k)
Pressure base;
(l)
Temperature base;
(m)
Static-pressure tap location (upstream or downstream);
(n)
Chart rotation (hours or days);
(o)
Differential-pressure bellows range (inches of water);
(p)
Static-pressure element range (psi); and
(q)
For each chart or day integrated—
(i)
The time and date on and time and date off;
(ii)
Average differential pressure (inches of water);
(iii)
Average static pressure;
(iv)
Static-pressure units of measure (psia or psig);
(v)
Average temperature ( °F);
(vi)
Integrator counts or extension;
(vii)
Hours of flow; and
(viii)
Volume (Mcf).
Notes, amendments, and revision history

Source

Source: 81 FR 81609, Nov. 17, 2016, unless otherwise noted.

Authority

Authority: 25 U.S.C. 396d and 2107; 30 U.S.C. 189, 306, 359, and 1751; and 43 U.S.C. 1732(b), 1733, and 1740.

Source