US Codex
C.F.R.
Browse by date
Notes

§3174.12. Measurement tickets.

43 C.F.R. § 3174.12

(a)
Tank gauging. After oil is measured by tank gauging under §§ 3174.5 and 3174.6 of this subpart, the operator, purchaser, or transporter, as appropriate, must complete a uniquely numbered measurement ticket, in either paper or electronic format, with the following information:
(1)
Lease, unit PA, or CA number;
(2)
Unique tank number and nominal tank capacity;
(3)
Opening and closing dates and times;
(4)
Opening and closing gauges and observed temperatures in °F;
(5)
Observed volume for opening and closing gauge, using tank specific calibration charts (see § 3174.5(c));
(6)
Total gross standard volume removed from the tank following API 11.1 (incorporated by reference, see § 3174.3);
(7)
Observed API oil gravity and temperature in °F;
(8)
API oil gravity at 60 °F, following API 11.1 (incorporated by reference, see § 3174.3);
(9)
S&W content percent;
(10)
Unique number of each seal removed and installed;
(11)
Name of the individual performing the tank gauging; and
(12)
Name of the operator.
(b)
LACT system and CMS.
(1)
At the beginning of every month, and, unless the operator is using a flow computer under § 3174.10, before conducting proving operations on a LACT system, the operator, purchaser, or transporter, as appropriate, must complete a uniquely numbered measurement ticket, in either paper or electronic format, with the following information:
(i)
Lease, unit PA, or CA number;
(ii)
Unique meter ID number;
(iii)
Opening and closing dates;
(iv)
Opening and closing totalizer readings of the indicated volume;
(v)
Meter factor, indicating if it is a composite meter factor;
(vi)
Total gross standard volume removed through the LACT system or CMS;
(vii)
API oil gravity. For API oil gravity determined from a composite sample, the observed API oil gravity and temperature must be indicated in °F and the API oil gravity must be indicated at 60 °F. For API oil gravity determined from average density (CMS only), the average uncorrected density must be determined by the CMS;
(viii)
The average temperature in °F;
(ix)
The average flowing pressure in psig;
(x)
S&W content percent;
(xi)
Unique number of each seal removed and installed;
(xii)
Name of the purchaser's representative; and
(xiii)
Name of the operator.
(2)
Any accumulators used in the determination of average pressure, average temperature, and average density must be reset to zero whenever a new measurement ticket is opened.
Notes, amendments, and revision history

Source

Source: 81 FR 81504, Nov. 17, 2016, unless otherwise noted.

Authority

Authority: 25 U.S.C. 396d and 2107; 30 U.S.C. 189, 306, 359, and 1751; and 43 U.S.C. 1732(b), 1733, and 1740.

Source

Source: 81 FR 81421, Nov. 17, 2016, unless otherwise noted.