§3173.3. Oil measurement system components—seals.

43 C.F.R. § 3173.3

(a)
Components used for quantity or quality determination of oil must be effectively sealed to indicate tampering, including, but not limited to, the following components of LACT meters (see § 3174.8(a)) and CMSs (see § 3174.9(e)):
(1)
Sample probe;
(2)
Sampler volume control;
(3)
All valves on lines entering or leaving the sample container, excluding the safety pop-off valve (if so equipped). Each valve must be sealed in the open or closed position, as appropriate;
(4)
Meter assembly, including the counter head and meter head;
(5)
Temperature averager;
(6)
LACT meters or CMS;
(7)
Back pressure valve pressure adjustment downstream of the meter;
(8)
Any drain valves in the system;
(9)
Manual-sampling valves (if so equipped);
(10)
Valves on diverter lines larger than 1 inch in nominal diameter;
(11)
Right-angle drive;
(12)
Totalizer; and
(13)
Prover connections.
(b)
Each missing or ineffectively sealed component is a separate violation.