§84.163. Man test for gases and vapors; Type C supplied-air respirators, demand and pressure-demand classes; test requirements.

42 C.F.R. § 84.163

(a)
The completely assembled respirator will be worn in a chamber containing 0.1 ±0.025 percent isoamyl acetate vapor, the intake of the hose will be connected to a suitable source of respirable air, and not more than 25 percent of the hose length will be located in isoamyl acetate-free air.
(b)
The test will be conducted at the minimum pressure with the maximum hose length and will be repeated at the maximum pressure with the minimum hose length.