§98.98. Definitions. — Inbound Citations
40 C.F.R. § 98.98
Statutory Authority
Cited by 8 regulations in release Current.
Citations to 40 C.F.R. § 98.98 as a whole
-
(4) For facilities, except as otherwise provided in paragraph (c)(12) of this section, report annual emissions of CO2, CH4, N2O, each fluorinated GHG (as defined in § 98.6), and each fluorinated heat transfer fluid (as defined in § 98.98) as follows.(i) Annual emissions (excluding biogenic CO2) aggregated for all GHG from all applicable source categories, expressed in metric tons of CO2e calculated using Equation A-1 of this subpart. For electronics manufacturing (as defined in § 98.90), starting in reporting year 2012 the CO2e calculation must include each fluorinated heat transfer fluid (as defined in § 98.98) whether or not it is also a fluorinated GHG.(ii) Annual emissions of biogenic CO2 aggregated for all applicable source categories, expressed in metric tons.(iii) Annual emissions from each applicable source category, expressed in metric tons of each applicable GHG listed in paragraphs (c)(4)(iii)(A) through (F) of this section.(E) Each fluorinated GHG (as defined in § 98.6), except fluorinated gas production facilities must comply with § 98.126(a) rather than this paragraph (c)(4)(iii)(E). If a fluorinated GHG does not have a chemical-specific GWP in Table A-1 of this subpart, identify and report the fluorinated GHG group of which that fluorinated GHG is a member.(F) For electronics manufacturing (as defined in § 98.90), each fluorinated heat transfer fluid (as defined in § 98.98) that is not also a fluorinated GHG as specified under (c)(4)(iii)(E) of this section. If a fluorinated heat transfer fluid does not have a chemical-specific GWP in Table A-1 of this subpart, identify and report the fluorinated GHG group of which that fluorinated heat transfer fluid is a member.(G) For each reported fluorinated GHG and fluorinated heat transfer fluid, report the following identifying information:(1) Chemical name. If the chemical is not listed in Table A-1 of this subpart, then use the method of naming organic chemical compounds as recommended by the International Union of Pure and Applied Chemistry (IUPAC).(2) The CAS registry number assigned by the Chemical Abstracts Registry Service. If a CAS registry number is not assigned or is not associated with a single fluorinated GHG or fluorinated heat transfer fluid, then report an identification number assigned by EPA's Substance Registry Services.(3) Linear chemical formula.(iv) Except as provided in paragraph (c)(4)(vii) of this section, emissions and other data for individual units, processes, activities, and operations as specified in the “Data reporting requirements” section of each applicable subpart of this part.(v) Indicate (yes or no) whether reported emissions include emissions from a cogeneration unit located at the facility.(vi) [Reserved](vii) The owner or operator of a facility is not required to report the data elements specified in Table A-6 of this subpart for calendar years 2010 through 2011 until March 31, 2013. The owner or operator of a facility is not required to report the data elements specified in Table A-7 of this subpart for calendar years 2010 through 2013 until March 31, 2015 (as part of the annual report for reporting year 2014), except as otherwise specified in Table A-7 of this subpart.
-
(a) You must calculate total annual emissions of each fluorinated GHG emitted by electronics manufacturing production processes from each fab (as defined in § 98.98) at your facility, including each input gas and each by-product gas. You must use either default gas utilization rates and by-product formations rates according to the procedures in paragraph (a)(1), (2), (6), or (7) of this section, as appropriate, or the stack test method according to paragraph (i) of this section, to calculate emissions of each input gas and each by-product gas.(1) If you manufacture semiconductors, you must adhere to the procedures in paragraphs (a)(1)(i) through (iii) of this section. You must calculate annual emissions of each input gas and of each by-product gas using equations I-6, I-7, and I-9 to this section. If your fab uses less than 50 kg of a fluorinated GHG in one reporting year, you may calculate emissions as equal to your fab's annual consumption for that specific gas as calculated in equation I-11 to this section, plus any by-product emissions of that gas calculated under paragraph (a) of this section.(i) You must calculate annual fab-level emissions of each fluorinated GHG used for the plasma etching/wafer cleaning process type using default utilization and by-product formation rates as shown in table I-3 or I-4 to this subpart, and by using equations I-8A and I-8B to this section.(ii) You must calculate annual fab-level emissions of each fluorinated GHG used for each of the process sub-types associated with the chamber cleaning process type, including in-situ plasma chamber clean, remote plasma chamber clean, and in-situ thermal chamber clean, using default utilization and by-product formation rates as shown in table I-3 or I-4 to this subpart, and by using equations I-8A and I-8B to this section.(iii) If default values are not available for a particular input gas and process type or sub-type combination in tables I-3 or I-4, you must follow the procedures in paragraph (a)(6) of this section.(2) If you manufacture MEMS or PVs and use semiconductor tools and processes, you may use § 98.3(a)(1) to calculate annual fab-level emissions for those processes. For all other tools and processes used to manufacture MEMs, LCD and PV, you must calculate annual fab-level emissions of each fluorinated GHG used for the plasma etching and chamber cleaning process types using default utilization and by-product formation rates as shown in table I-5, I-6, or I-7 to this subpart, as appropriate, and by using equations I-8A and I-8B to this section. If default values are not available for a particular input gas and process type or sub-type combination in tables I-5, I-6, or I-7 to this subpart, you must follow the procedures in paragraph (a)(6) of this section. If your fab uses less than 50 kg of a fluorinated GHG in one reporting year, you may calculate emissions as equal to your fab's annual consumption for that specific gas as calculated in equation I-11 to this section, plus any by-product emissions of that gas calculated under this paragraph (a).(3) -(5) [Reserved](6) If you are required, or elect, to perform calculations using default emission factors for gas utilization and by-product formation rates according to the procedures in paragraph (a)(1) or (2) of this section, and default values are not available for a particular input gas and process type or sub-type combination in tables I-3, I-4, I-5, I-6, or I-7 to this subpart, you must use a utilization rate (Uij) of 0.2 (i.e., a 1-Uij of 0.8) and by-product formation rates of 0.15 for CF4 and 0.05 for C2F6 and use equations I-8A and I-8B to this section.(7) If your fab employs hydrocarbon-fuel-based combustion emissions control systems (HC fuel CECS), including, but not limited to, abatement systems as defined at § 98.98, that were purchased and installed on or after January 1, 2025, to control emissions from tools that use either NF3 in remote plasma cleaning processes or F2 as an input gas in any process type or sub-type, you must calculate the amount CF4 produced within and emitted from such systems using equation I-9 to this section using default utilization and by-product formation rates as shown in table I-3 or I-4 to this subpart. A HC fuel CECS is assumed not to form CF4 from F2 if the electronics manufacturer can certify that the rate of conversion from F2 to CF4 is <0.1% for that HC fuel CECS.
-
(1) You must demonstrate that the fluorinated GHG and N2O apportioning factors are developed using calculations that are repeatable, as defined in § 98.98.
-
(o) For all HC fuel CECS that were purchased and installed on or after January 1, 2025, that are used to control emissions from tools that use either NF3 as an input gas in remote plasma clean processes or F2 as an input gas in any process type or sub-type and for which you are not calculating emissions under equation I-9 to § 98.93, certification that the rate of conversion from F2 to CF4 is <0.1% and that the systems are installed, operated, and maintained in accordance with the directions of the HC fuel CECS manufacturer. Hydrocarbon-fuel-based combustion emissions control systems include but are not limited to abatement systems as defined in § 98.98 that are hydrocarbon-fuel-based. If you make the certification based on your own testing, you must certify that you tested the model of the system according to the requirements specified in § 98.94(e). If you make the certification based on testing by the HC fuel CECS manufacturer, you must provide documentation from the HC fuel CECS manufacturer that the rate of conversion from F2 to CF4 is <0.1% when tested according to the requirements specified in § 98.94(e).
-
(4) Calculations and data used to determine and document that the fab was operating at representative operating levels, as defined in § 98.98, during the apportioning model verification specified in § 98.94(c).
Citations to §98.98(1)
-
Except as provided in this section, all of the terms used in this subpart have the same meaning given in the Clean Air Act and subpart A of this part. If a conflict exists between a definition provided in this subpart and a definition provided in subpart A, the definition in this subpart takes precedence for the reporting requirements in this subpart.
Citations to §98.98(2)
-
Except as provided in this section, all of the terms used in this subpart have the same meaning given in the Clean Air Act and subpart A of this part. If a conflict exists between a definition provided in this subpart and a definition provided in subpart A, the definition in this subpart takes precedence for the reporting requirements in this subpart.
Citations to §98.98(3)
-
Except as provided in this section, all of the terms used in this subpart have the same meaning given in the Clean Air Act and subpart A of this part. If a conflict exists between a definition provided in this subpart and a definition provided in subpart A, the definition in this subpart takes precedence for the reporting requirements in this subpart.