(1) For a mass flow meter, you must calculate the total annual mass of CO2 in a CO2 stream received in metric tons by multiplying the mass flow by the CO2 concentration in the flow, according to Equation RR-1 of this section. You must collect these data quarterly. Mass flow and concentration data measurements must be made in accordance with § 98.444.
-
(3) If an owner or operator demonstrates that monitoring employed under §§ 98.440 to 98.449 of this chapter (Clean Air Act, 42 U.S.C. 7401 et seq.) accomplishes the goals of paragraphs (h)(1) and (2) of this section, and meets the requirements pursuant to § 146.91(c)(5), a Director that requires surface air/soil gas monitoring must approve the use of monitoring employed under §§ 98.440 to 98.449 of this chapter. Compliance with §§ 98.440 to 98.449 of this chapter pursuant to this provision is considered a condition of the Class VI permit;
Citations to §98.444(a)(1)
-
(1) Another calculation methodology listed in § 98.444(a)(1) must be used if possible.
Citations to §98.444(a)(2)
-
(1) Another calculation methodology listed in § 98.444(a)(2) must be used if possible.
Citations to §98.444(a)(2)(i)
-
(1) If you are measuring the mass of contents in a container under the provisions of § 98.444(a)(2)(i), you must calculate the CO2 received for injection in containers using Equation RR-1 of this section.
Citations to §98.444(a)(2)(ii)
-
(2) If you are measuring the volume of contents in a container under the provisions of § 98.444(a)(2)(ii), you must calculate the CO2 received for injection in containers using Equation RR-2 of this section.
Citations to §98.444(a)(3)
-
(1) Another calculation methodology listed in § 98.444(a)(3) must be used if possible.
Citations to §98.444(a)(4)
-
You must calculate the mass of CO2 received using CO2 received equations (Equations RR-1 to RR-3 of this section), unless you follow the procedures in § 98.444(a)(4). You must calculate CO2 sequestered using injection equations (Equations RR-4 to RR-6 of this section), production/recycling equations (Equations RR-7 to RR-9 of this section), surface leakage equations (Equation RR-10 of this section), and sequestration equations (Equations RR-11 and RR-12 of this section). For your first year of reporting, you must calculate CO2 sequestered starting from the date set forth in your approved MRV plan.
-
(4) If the CO2 received is wholly injected and not mixed with any other supply of CO2, report whether you followed the procedures in § 98.444(a)(4).
Citations to §98.444(f)(1)
-
(3) To aggregate production data, you must sum the mass of all of the CO2 separated at each gas-liquid separator in accordance with the procedure specified in Equation RR-9 of this section. You must assume that the total CO2 measured at the separator(s) represents a percentage of the total CO2 produced. In order to account for the percentage of CO2 produced that is estimated to remain with the produced oil or other fluid, you must multiply the quarterly mass of CO2 measured at the separator(s) by a percentage estimated using a methodology in your approved MRV plan. If fluids containing CO2 from injection wells covered under this source category are produced and not processed through a gas-liquid separator, the concentration of CO2 in the produced fluids must be measured at a flow meter located prior to reinjection or reuse using methods in § 98.444(f)(1). The considerations you intend to use to calculate CO2 from produced fluids for the mass balance equation must be described in your approved MRV plan in accordance with § 98.448(a)(5).