§98.443. Calculating CO 2 geologic sequestration. — Inbound Citations
40 C.F.R. § 98.443
Statutory Authority
Cited by 9 regulations in release Current.
Citations to 40 U.S.C. § 98.443 as a whole
-
(3) If an owner or operator demonstrates that monitoring employed under §§ 98.440 to 98.449 of this chapter (Clean Air Act, 42 U.S.C. 7401 et seq.) accomplishes the goals of paragraphs (h)(1) and (2) of this section, and meets the requirements pursuant to § 146.91(c)(5), a Director that requires surface air/soil gas monitoring must approve the use of monitoring employed under §§ 98.440 to 98.449 of this chapter. Compliance with §§ 98.440 to 98.449 of this chapter pursuant to this provision is considered a condition of the Class VI permit;
Citations to §98.443(a)
-
(3) For 2011, you may follow the provisions of § 98.3(d)(1) through (2) for best available monitoring methods only for parameters required by paragraphs (a) and (b) of § 98.443 rather than follow the monitoring requirements of paragraph (a) of this section. For purposes of this subpart, any reference to the year 2010 in § 98.3(d)(1) through (2) shall mean 2011.
Citations to §98.443(b)
-
(3) For 2011, you may follow the provisions of § 98.3(d)(1) through (2) for best available monitoring methods only for parameters required by paragraphs (a) and (b) of § 98.443 rather than follow the monitoring requirements of paragraph (a) of this section. For purposes of this subpart, any reference to the year 2010 in § 98.3(d)(1) through (2) shall mean 2011.
Citations to §98.443(c)(1)
-
(c) You must report the annual mass of CO2 injected in accordance with the procedures specified in paragraphs (c)(1) through (c)(3) of this section.(1) If you use a mass flow meter to measure the flow of an injected CO2 stream, you must calculate annually the total mass of CO2 (in metric tons) in the CO2 stream injected each year in metric tons by multiplying the mass flow by the CO2 concentration in the flow, according to Equation RR-4 of this section. Mass flow and concentration data measurements must be made in accordance with § 98.444.(2) If you use a volumetric flow meter to measure the flow of an injected CO2 stream, you must calculate annually the total mass of CO2 (in metric tons) in the CO2 stream injected each year in metric tons by multiplying the volumetric flow at standard conditions by the CO2 concentration in the flow and the density of CO2 at standard conditions, according to Equation RR-5 of this section. Volumetric flow and concentration data measurements must be made in accordance with § 98.444.(3) To aggregate injection data for all wells covered under this subpart, you must sum the mass of all CO2 injected through all injection wells in accordance with the procedure specified in Equation RR-6 of this section.
Citations to §98.443(c)(2)
-
(c) You must report the annual mass of CO2 injected in accordance with the procedures specified in paragraphs (c)(1) through (c)(3) of this section.(1) If you use a mass flow meter to measure the flow of an injected CO2 stream, you must calculate annually the total mass of CO2 (in metric tons) in the CO2 stream injected each year in metric tons by multiplying the mass flow by the CO2 concentration in the flow, according to Equation RR-4 of this section. Mass flow and concentration data measurements must be made in accordance with § 98.444.(2) If you use a volumetric flow meter to measure the flow of an injected CO2 stream, you must calculate annually the total mass of CO2 (in metric tons) in the CO2 stream injected each year in metric tons by multiplying the volumetric flow at standard conditions by the CO2 concentration in the flow and the density of CO2 at standard conditions, according to Equation RR-5 of this section. Volumetric flow and concentration data measurements must be made in accordance with § 98.444.(3) To aggregate injection data for all wells covered under this subpart, you must sum the mass of all CO2 injected through all injection wells in accordance with the procedure specified in Equation RR-6 of this section.
Citations to §98.443(c)(3)
-
(c) You must report the annual mass of CO2 injected in accordance with the procedures specified in paragraphs (c)(1) through (c)(3) of this section.(1) If you use a mass flow meter to measure the flow of an injected CO2 stream, you must calculate annually the total mass of CO2 (in metric tons) in the CO2 stream injected each year in metric tons by multiplying the mass flow by the CO2 concentration in the flow, according to Equation RR-4 of this section. Mass flow and concentration data measurements must be made in accordance with § 98.444.(2) If you use a volumetric flow meter to measure the flow of an injected CO2 stream, you must calculate annually the total mass of CO2 (in metric tons) in the CO2 stream injected each year in metric tons by multiplying the volumetric flow at standard conditions by the CO2 concentration in the flow and the density of CO2 at standard conditions, according to Equation RR-5 of this section. Volumetric flow and concentration data measurements must be made in accordance with § 98.444.(3) To aggregate injection data for all wells covered under this subpart, you must sum the mass of all CO2 injected through all injection wells in accordance with the procedure specified in Equation RR-6 of this section.
Citations to §98.443(d)(1)
-
(d) You must calculate the annual mass of CO2 produced from oil or gas production wells or from other fluid wells for each separator that sends a stream of gas into a recycle or end use system in accordance with the procedures specified in paragraphs (d)(1) through (d)(3) of this section. You must account for any CO2 that is produced and not processed through a separator. You must account only for wells that produce the CO2 that was injected into the well or wells covered by this source category.(1) For each gas-liquid separator for which flow is measured using a mass flow meter, you must calculate annually the total mass of CO2 produced from an oil or other fluid stream in metric tons that is separated from the fluid by multiplying the mass gas flow by the CO2 concentration in the gas flow, according to Equation RR-7 of this section. You must collect these data quarterly. Mass flow and concentration data measurements must be made in accordance with § 98.444.(2) For each gas-liquid separator for which flow is measured using a volumetric flow meter, you must calculate annually the total mass of CO2 produced from an oil or other fluid stream in metric tons that is separated from the fluid by multiplying the volumetric gas flow at standard conditions by the CO2 concentration in the gas flow and the density of CO2 at standard conditions, according to Equation RR-8 of this section. You must collect these data quarterly. Volumetric flow and concentration data measurements must be made in accordance with § 98.444.(3) To aggregate production data, you must sum the mass of all of the CO2 separated at each gas-liquid separator in accordance with the procedure specified in Equation RR-9 of this section. You must assume that the total CO2 measured at the separator(s) represents a percentage of the total CO2 produced. In order to account for the percentage of CO2 produced that is estimated to remain with the produced oil or other fluid, you must multiply the quarterly mass of CO2 measured at the separator(s) by a percentage estimated using a methodology in your approved MRV plan. If fluids containing CO2 from injection wells covered under this source category are produced and not processed through a gas-liquid separator, the concentration of CO2 in the produced fluids must be measured at a flow meter located prior to reinjection or reuse using methods in § 98.444(f)(1). The considerations you intend to use to calculate CO2 from produced fluids for the mass balance equation must be described in your approved MRV plan in accordance with § 98.448(a)(5).
Citations to §98.443(d)(2)
-
(d) You must calculate the annual mass of CO2 produced from oil or gas production wells or from other fluid wells for each separator that sends a stream of gas into a recycle or end use system in accordance with the procedures specified in paragraphs (d)(1) through (d)(3) of this section. You must account for any CO2 that is produced and not processed through a separator. You must account only for wells that produce the CO2 that was injected into the well or wells covered by this source category.(1) For each gas-liquid separator for which flow is measured using a mass flow meter, you must calculate annually the total mass of CO2 produced from an oil or other fluid stream in metric tons that is separated from the fluid by multiplying the mass gas flow by the CO2 concentration in the gas flow, according to Equation RR-7 of this section. You must collect these data quarterly. Mass flow and concentration data measurements must be made in accordance with § 98.444.(2) For each gas-liquid separator for which flow is measured using a volumetric flow meter, you must calculate annually the total mass of CO2 produced from an oil or other fluid stream in metric tons that is separated from the fluid by multiplying the volumetric gas flow at standard conditions by the CO2 concentration in the gas flow and the density of CO2 at standard conditions, according to Equation RR-8 of this section. You must collect these data quarterly. Volumetric flow and concentration data measurements must be made in accordance with § 98.444.(3) To aggregate production data, you must sum the mass of all of the CO2 separated at each gas-liquid separator in accordance with the procedure specified in Equation RR-9 of this section. You must assume that the total CO2 measured at the separator(s) represents a percentage of the total CO2 produced. In order to account for the percentage of CO2 produced that is estimated to remain with the produced oil or other fluid, you must multiply the quarterly mass of CO2 measured at the separator(s) by a percentage estimated using a methodology in your approved MRV plan. If fluids containing CO2 from injection wells covered under this source category are produced and not processed through a gas-liquid separator, the concentration of CO2 in the produced fluids must be measured at a flow meter located prior to reinjection or reuse using methods in § 98.444(f)(1). The considerations you intend to use to calculate CO2 from produced fluids for the mass balance equation must be described in your approved MRV plan in accordance with § 98.448(a)(5).
Citations to §98.443(d)(3)
-
(d) You must calculate the annual mass of CO2 produced from oil or gas production wells or from other fluid wells for each separator that sends a stream of gas into a recycle or end use system in accordance with the procedures specified in paragraphs (d)(1) through (d)(3) of this section. You must account for any CO2 that is produced and not processed through a separator. You must account only for wells that produce the CO2 that was injected into the well or wells covered by this source category.(1) For each gas-liquid separator for which flow is measured using a mass flow meter, you must calculate annually the total mass of CO2 produced from an oil or other fluid stream in metric tons that is separated from the fluid by multiplying the mass gas flow by the CO2 concentration in the gas flow, according to Equation RR-7 of this section. You must collect these data quarterly. Mass flow and concentration data measurements must be made in accordance with § 98.444.(2) For each gas-liquid separator for which flow is measured using a volumetric flow meter, you must calculate annually the total mass of CO2 produced from an oil or other fluid stream in metric tons that is separated from the fluid by multiplying the volumetric gas flow at standard conditions by the CO2 concentration in the gas flow and the density of CO2 at standard conditions, according to Equation RR-8 of this section. You must collect these data quarterly. Volumetric flow and concentration data measurements must be made in accordance with § 98.444.(3) To aggregate production data, you must sum the mass of all of the CO2 separated at each gas-liquid separator in accordance with the procedure specified in Equation RR-9 of this section. You must assume that the total CO2 measured at the separator(s) represents a percentage of the total CO2 produced. In order to account for the percentage of CO2 produced that is estimated to remain with the produced oil or other fluid, you must multiply the quarterly mass of CO2 measured at the separator(s) by a percentage estimated using a methodology in your approved MRV plan. If fluids containing CO2 from injection wells covered under this source category are produced and not processed through a gas-liquid separator, the concentration of CO2 in the produced fluids must be measured at a flow meter located prior to reinjection or reuse using methods in § 98.444(f)(1). The considerations you intend to use to calculate CO2 from produced fluids for the mass balance equation must be described in your approved MRV plan in accordance with § 98.448(a)(5).