US Codex
C.F.R.
Browse by date
Notes

§98.34. Monitoring and QA/QC requirements. — Inbound Citations

40 C.F.R. § 98.34

Cited by 23 regulations in release Current.

Citations to 40 C.F.R. § 98.34 as a whole

  • (1) Except as provided in paragraph (b)(4) of this section, determine the mass of each process input and output other than fuels using the same plant instruments or procedures that are used for accounting purposes (such as weigh hoppers, belt weigh feeders, weighed purchased quantities in shipments or containers, combination of bulk density and volume measurements, etc.), record the totals for each process input and output for each calendar month, and sum the monthly mass to determine the annual mass for each process input and output. Determine the mass rate of fuels using the procedures for combustion units in § 98.34. No determination of the mass of steel output from decarburization vessels is required.
  • (ii) For fuels listed in paragraph (z)(1)(i) of this section, calculate CO2, CH4, and N2O emissions for each unit or group of units combusting the same fuel according to any Tier listed in subpart C of this part, except that each natural gas-fired reciprocating internal combustion engine or gas turbine must use one of the methods in paragraph (z)(4) of this section to quantify a CH4 emission factor instead of using the CH4 emission factor in table C-2 to subpart C of this part. You must follow all applicable calculation requirements for that tier listed in § 98.33, any monitoring or QA/QC requirements listed for that tier in § 98.34, any missing data procedures specified in § 98.35, and any recordkeeping requirements specified in § 98.37. You must report emissions according to paragraph (z)(5) of this section.
  • (a) Fuel flow meters, gas composition monitors, and heating value monitors that are associated with sources that use a CEMS to measure CO2 emissions according to subpart C of this part or that are associated with stationary combustion sources must meet the applicable monitoring and QA/QC requirements in § 98.34.
  • (1) Calculate CO2 emissions from fuel combustion using direct measurement of fuels consumed and default emissions factors according to the Tier 1 methodology for stationary combustion sources in § 98.33(a)(1). Tiers 2 or 3 from § 98.33(a)(2) or (3) may be used to calculate CO2 emissions if the respective monitoring and QA/QC requirements described in § 98.34 are met.
  • (a) Each facility subject to this subpart must quality assure the GHG emissions data according to the applicable requirements in § 98.34. All QA/QC data must be available for inspection upon request.
  • (ii) The minimum required sampling frequency for determining the annual average HHV (e.g., monthly, quarterly, semi-annually, or by lot) is specified in § 98.34. The method for computing the annual average HHV is a function of unit size and how frequently you perform or receive from the fuel supplier the results of fuel sampling for HHV. The method is specified in paragraph (a)(2)(ii)(A) or (a)(2)(ii)(B) of this section, as applicable.
    (A) If the results of fuel sampling are received monthly or more frequently, then for each unit with a maximum rated heat input capacity greater than or equal to 100 mmBtu/hr (or for a group of units that includes at least one unit of that size), the annual average HHV shall be calculated using Equation C-2b of this section. If multiple HHV determinations are made in any month, average the values for the month arithmetically.
    (B) If the results of fuel sampling are received less frequently than monthly, or, for a unit with a maximum rated heat input capacity less than 100 mmBtu/hr (or a group of such units) regardless of the HHV sampling frequency, the annual average HHV shall either be computed according to paragraph (a)(2)(ii)(A) of this section or as the arithmetic average HHV for all values for the year (including valid samples and substitute data values under § 98.35).
  • (a) Flow meters, gas composition monitors, and heating value monitors that are associated with sources that use a CEMS to measure CO2 emissions according to subpart C of this part or that are associated with stationary combustion sources must meet the applicable monitoring and QA/QC requirements in § 98.34.

Citations to §98.34(a)

Citations to §98.34(b)

  • (3) When two or more stationary combustion units at a facility combust the same type of liquid or gaseous fuel and the fuel is fed to the individual units through a common supply line or pipe, you may report the combined emissions from the units served by the common supply line, in lieu of separately reporting the GHG emissions from the individual units, provided that the total amount of fuel combusted by the units is accurately measured at the common pipe or supply line using a fuel flow meter, or, for natural gas, the amount of fuel combusted may be obtained from gas billing records. For Tier 3 applications, the flow meter shall be calibrated in accordance with § 98.34(b). If a portion of the fuel measured (or obtained from gas billing records) at the main supply line is diverted to either: A flare; or another stationary fuel combustion unit (or units), including units that use a CO2 mass emissions calculation method in part 75 of this chapter; or a chemical or industrial process (where it is used as a raw material but not combusted), and the remainder of the fuel is distributed to a group of combustion units for which you elect to use the common pipe reporting option, you may use company records to subtract out the diverted portion of the fuel from the fuel measured (or obtained from gas billing records) at the main supply line prior to performing the GHG emissions calculations for the group of units using the common pipe option. If the diverted portion of the fuel is combusted, the GHG emissions from the diverted portion shall be accounted for in accordance with the applicable provisions of this part. When the common pipe option is selected, the applicable tier shall be used based on the maximum rated heat input capacity of the largest unit served by the common pipe configuration, except where the applicable tier is based on criteria other than unit size. For example, if the maximum rated heat input capacity of the largest unit is greater than 250 mmBtu/hr, Tier 3 will apply, unless the fuel transported through the common pipe is natural gas or distillate oil, in which case Tier 2 may be used, in accordance with § 98.33(b)(2)(ii). As a second example, in accordance with § 98.33(b)(1)(v), Tier 1 may be used regardless of unit size when natural gas is transported through the common pipe, if the annual fuel consumption is obtained from gas billing records in units of therms or mmBtu. When the common pipe reporting option is selected, the following information shall be reported instead of the information in paragraph (b) of this section:
    (ii) The cumulative maximum rated heat input capacity shall be determined as the sum of the maximum rated heat input capacities for all units served by the common pipe, excluding units less than 10 (mmBtu/hr).
    (v) The methodology used to calculate the CO2 mass emissions (i.e., Tier 1, Tier 2, or Tier 3).
    (vi) If any of the units burns biomass, the annual CO2 emissions from combustion of all biomass fuels from the units served by the common pipe, expressed in metric tons.
    (vii) Annual CO2 mass emissions and annual CH4 and N2O emissions from each fuel type for the units served by the common pipe, expressed in metric tons of each gas and in metric tons of CO2e.
    (x) If applicable, the plant code (as defined in § 98.6).
    (xi) For natural gas-fired reciprocating internal combustion engines or gas turbines at facilities subject to subpart W of this part, which must use a CH4 emission factor determined in accordance with § 98.233(z)(4), you must report the equipment type (i.e., two-stroke lean-burn reciprocating internal combustion engine, four-stroke lean-burn reciprocating internal combustion engine, four-stroke rich-burn reciprocating internal combustion engine, and gas turbine) the method by which the CH4 emission factor was determined (i.e., performance test, manufacturer data, or default emission factor), and the average value of the CH4 emission factor.

Citations to §98.34(b)(1)

  • (1) Calibrate all oil and gas flow meters that are used to measure liquid and gaseous fuel and feedstock volumes (except for gas billing meters) according to the monitoring and QA/QC requirements for the Tier 3 methodology in § 98.34(b)(1). Perform oil tank drop measurements (if used to quantify liquid fuel or feedstock consumption) according to § 98.34(b)(2). Calibrate all solids weighing equipment according to the procedures in § 98.3(i).
  • (d) Calibrate all oil and gas flow meters that are used to measure liquid and gaseous feedstock volumes and flow rates (except for gas billing meters) according to the monitoring and QA/QC requirements for the Tier 3 methodology in § 98.34(b)(1). Perform oil tank drop measurements (if used to quantify feedstock volumes) according to § 98.34(b)(2).

Citations to §98.34(b)(2)

  • (1) Calibrate all oil and gas flow meters that are used to measure liquid and gaseous fuel and feedstock volumes (except for gas billing meters) according to the monitoring and QA/QC requirements for the Tier 3 methodology in § 98.34(b)(1). Perform oil tank drop measurements (if used to quantify liquid fuel or feedstock consumption) according to § 98.34(b)(2). Calibrate all solids weighing equipment according to the procedures in § 98.3(i).
  • (d) Calibrate all oil and gas flow meters that are used to measure liquid and gaseous feedstock volumes and flow rates (except for gas billing meters) according to the monitoring and QA/QC requirements for the Tier 3 methodology in § 98.34(b)(1). Perform oil tank drop measurements (if used to quantify feedstock volumes) according to § 98.34(b)(2).

Citations to §98.34(c)

Citations to §98.34(d)

  • (ii) Determine the relative proportions of biogenic and non-biogenic CO2 emissions in the flue gas on a quarterly basis using the method specified in § 98.34(d) (for units that combust MSW as the primary fuel or as the only fuel with a biogenic component) or in § 98.34(e) (for other units, including units that combust tires).
  • (x) When ASTM methods D7459-08 and D6866-16 (both incorporated by reference, see § 98.7) are used to determine the biogenic portion of the annual CO2 emissions from MSW combustion, as described in § 98.34(d), report:
    (A) The results of each quarterly sample analysis, expressed as a decimal fraction (e.g., if the biogenic fraction of the CO2 emissions from MSW combustion is 30 percent, report 0.30).
  • (40) ASTM D6866-16, Standard Test Methods for Determining the Biobased Content of Solid, Liquid, and Gaseous Samples Using Radiocarbon Analysis, approved June 1, 2016; IBR approved for §§ 98.34(d) and (e); 98.36(e).

Citations to §98.34(e)

  • (ii) Determine the relative proportions of biogenic and non-biogenic CO2 emissions in the flue gas on a quarterly basis using the method specified in § 98.34(d) (for units that combust MSW as the primary fuel or as the only fuel with a biogenic component) or in § 98.34(e) (for other units, including units that combust tires).
  • (xi) When ASTM methods D7459-08 and D6866-16 (both incorporated by reference, see § 98.7) are used in accordance with § 98.34(e) to determine the biogenic portion of the annual CO2 emissions from a unit that co-fires biogenic fuels (or partly-biogenic fuels, including tires) and non-biogenic fuels, you shall report the results of each quarterly sample analysis, expressed as a decimal fraction (e.g., if the biogenic fraction of the CO2 emissions is 30 percent, report 0.30).
  • (40) ASTM D6866-16, Standard Test Methods for Determining the Biobased Content of Solid, Liquid, and Gaseous Samples Using Radiocarbon Analysis, approved June 1, 2016; IBR approved for §§ 98.34(d) and (e); 98.36(e).

Citations to §98.34(f)