§98.293. Calculating GHG emissions. — Inbound Citations
40 C.F.R. § 98.293
Statutory Authority
Cited by 12 regulations in release Current.
Citations to 40 C.F.R. § 98.293 as a whole
-
Section 98.293 provides three different procedures for emission calculations. The appropriate paragraphs (a) through (c) of this section should be used for the procedure chosen.
-
(1) Inorganic carbon content in trona input, from the carbon analysis results for month (percent by weight, expressed as a decimal fraction) (Equation CC-1 of § 98.293).
Citations to §98.293(b)(2)
-
(a) If you determine your emissions using § 98.293(b)(2) (Equation CC-1 of this subpart) you must:(1) Determine the monthly inorganic carbon content of the trona from a weekly composite analysis for each soda ash manufacturing line, using a modified version of ASTM E359-00 (Reapproved 2005)e1, Standard Test Methods for Analysis of Soda Ash (Sodium Carbonate) (incorporated by reference, see § 98.7). ASTM E359-00(Reapproved 2005) e1 is designed to measure the total alkalinity in soda ash not in trona. The modified method referred to above adjusts the regular ASTM method to express the results in terms of trona. Although ASTM E359-00 (Reapproved 2005) e1 uses manual titration, suitable autotitrators may also be used for this determination.(2) Measure the mass of trona input to each soda ash manufacturing line on a monthly basis using belt scales or methods used for accounting purposes.
-
For the emission calculation methodologies in § 98.293(b)(2) and (b)(3), a complete record of all measured parameters used in the GHG emissions calculations is required (e.g., inorganic carbon content values, etc.). Therefore, whenever a quality-assured value of a required parameter is unavailable, a substitute data value for the missing parameter shall be used in the calculations as specified in the paragraphs (a) through (d) of this section. You must document and keep records of the procedures used for all such missing value estimates.
Citations to §98.293(b)(3)
-
(c) If you calculate CO2 emissions using the site-specific emission factor method in § 98.293(b)(3), you must:(1) Conduct an annual performance test that is based on representative performance (i.e., performance based on normal operating conditions) of the affected process.(3) Conduct the stack test using EPA Method 3A at 40 CFR part 60, appendix A-2 to measure the CO2 concentration, Method 2, 2A, 2C, 2D, or 2F at 40 CFR part 60, appendix A-1 or Method 26 at 40 CFR part 60, appendix A-2 to determine the stack gas volumetric flow rate. All QA/QC procedures specified in the reference test methods and any associated performance specifications apply. For each test, the facility must prepare an emission factor determination report that must include the items in paragraphs (c)(3)(i) through (c)(3)(iii) of this section.(iii) You must determine the average process vent flow rate from the mine water stripper/evaporater during each test and document how it was determined.(4) You must also determine the annual vent flow rate from the mine water stripper/evaporater from monthly information using the same plant instruments or procedures used for accounting purposes (i.e., volumetric flow meter).
-
For the emission calculation methodologies in § 98.293(b)(2) and (b)(3), a complete record of all measured parameters used in the GHG emissions calculations is required (e.g., inorganic carbon content values, etc.). Therefore, whenever a quality-assured value of a required parameter is unavailable, a substitute data value for the missing parameter shall be used in the calculations as specified in the paragraphs (a) through (d) of this section. You must document and keep records of the procedures used for all such missing value estimates.
-
(10) If you produce soda ash using the liquid alkaline feedstock process and use the site-specific emission factor method (§ 98.293(b)(3)) to estimate emissions then you must report the following relevant information for each manufacturing line or stack:(iii) CO2 emission factor (metric tons CO2/metric tons of process vent flow from mine water stripper/evaporator).
-
(5) If you produce soda ash using the liquid alkaline feedstock process and use the site-specific emission factor method to estimate emissions (§ 98.293(b)(3)) then you must also retain the following relevant information:(ii) You must document the procedures used to ensure the accuracy of the annual average vent flow measurements including, but not limited to, calibration of flow rate meters and other measurement devices. The estimated accuracy of measurements made with these devices must also be recorded, and the technical basis for these estimates must be provided.
Citations to §98.293(b)(3)(i)
-
(3) Use Equations CC-3, CC-4, and CC-5 of this section to determine annual CO2 process emissions from manufacturing lines that use the liquid alkaline feedstock process to produce soda ash. You must conduct an annual performance test and measure CO2 emissions and flow rates at all process vents from the mine water stripper/evaporator for each manufacturing line and calculate CO2 emissions as described in paragraphs (b)(3)(i) through (b)(3)(iv) of this section.(i) During the performance test, you must measure the process vent flow from each process vent during the test and calculate the average rate for the test period in metric tons per hour.(ii) Using the test data, you must calculate the hourly CO2 emission rate using Equation CC-3 of this section:(iii) Using the test data, you must calculate a CO2 emission factor for the process using Equation CC-4 of this section:(iv) You must calculate annual CO2 process emissions from each manufacturing line using Equation CC-5 of this section:
Citations to §98.293(b)(3)(ii)
-
(3) Use Equations CC-3, CC-4, and CC-5 of this section to determine annual CO2 process emissions from manufacturing lines that use the liquid alkaline feedstock process to produce soda ash. You must conduct an annual performance test and measure CO2 emissions and flow rates at all process vents from the mine water stripper/evaporator for each manufacturing line and calculate CO2 emissions as described in paragraphs (b)(3)(i) through (b)(3)(iv) of this section.(i) During the performance test, you must measure the process vent flow from each process vent during the test and calculate the average rate for the test period in metric tons per hour.(ii) Using the test data, you must calculate the hourly CO2 emission rate using Equation CC-3 of this section:(iii) Using the test data, you must calculate a CO2 emission factor for the process using Equation CC-4 of this section:(iv) You must calculate annual CO2 process emissions from each manufacturing line using Equation CC-5 of this section:
Citations to §98.293(b)(3)(iii)
-
(3) Use Equations CC-3, CC-4, and CC-5 of this section to determine annual CO2 process emissions from manufacturing lines that use the liquid alkaline feedstock process to produce soda ash. You must conduct an annual performance test and measure CO2 emissions and flow rates at all process vents from the mine water stripper/evaporator for each manufacturing line and calculate CO2 emissions as described in paragraphs (b)(3)(i) through (b)(3)(iv) of this section.(i) During the performance test, you must measure the process vent flow from each process vent during the test and calculate the average rate for the test period in metric tons per hour.(ii) Using the test data, you must calculate the hourly CO2 emission rate using Equation CC-3 of this section:(iii) Using the test data, you must calculate a CO2 emission factor for the process using Equation CC-4 of this section:(iv) You must calculate annual CO2 process emissions from each manufacturing line using Equation CC-5 of this section:
Citations to §98.293(b)(3)(iv)
-
(3) Use Equations CC-3, CC-4, and CC-5 of this section to determine annual CO2 process emissions from manufacturing lines that use the liquid alkaline feedstock process to produce soda ash. You must conduct an annual performance test and measure CO2 emissions and flow rates at all process vents from the mine water stripper/evaporator for each manufacturing line and calculate CO2 emissions as described in paragraphs (b)(3)(i) through (b)(3)(iv) of this section.(i) During the performance test, you must measure the process vent flow from each process vent during the test and calculate the average rate for the test period in metric tons per hour.(ii) Using the test data, you must calculate the hourly CO2 emission rate using Equation CC-3 of this section:(iii) Using the test data, you must calculate a CO2 emission factor for the process using Equation CC-4 of this section:(iv) You must calculate annual CO2 process emissions from each manufacturing line using Equation CC-5 of this section: