§82.27. Incorporation by reference. — Inbound Citations
40 C.F.R. § 82.27
Statutory Authority
Cited by 1 regulation in release Current.
Citations to 40 C.F.R. § 82.27 as a whole
-
(A) For process vent emission calculations, each entity may use any of paragraph (c)(1)(i)(A)(1), (2), or (3) of this section.(1) U.S. Environmental Protection Agency, Emission Inventory Improvement Program, Volume II: Chapter 16, Methods for Estimating Air Emissions from Chemical Manufacturing Facilities, August 2007, Final (incorporated by reference, see § 82.27).(2) Each entity may determine the controlled substance emissions from any process vent within the process using the procedures specified in § 63.1257(d)(2)(i) and (d)(3)(i)(B) of this chapter, except as specified in paragraphs (c)(1)(i)(A)(2)(i) through (iv) of this section. For the purposes of this section, use of the term “HAP” in § 63.1257(d)(2)(i) and (d)(3)(i)(B) of this chapter means “controlled substance.”(i) To calculate emissions caused by the heating of a vessel without a process condenser to a temperature lower than the boiling point, each entity must use the procedures in § 63.1257(d)(2)(i)(C)(3) of this chapter.(ii) To calculate emissions from depressurization of a vessel without a process condenser, each entity must use the procedures in § 63.1257(d)(2)(i)(D)(10) of this chapter.(iii) To calculate emissions from vacuum systems, the terms used in equation 33 to § 63.1257(d)(2)(i)(E) of this chapter are defined as follows. Psystem means the absolute pressure of the receiving vessel. P i means the partial pressure of the controlled substance determined at the exit temperature and exit pressure conditions of the condenser or at the conditions of the dedicated receiver. Pj means the partial pressure of condensables (including controlled substances) determined at the exit temperature and exit pressure conditions of the condenser or at the conditions of the dedicated receiver. MWcontrolled substance means the molecular weight of the controlled substance determined at the exit temperature and exit pressure conditions of the condenser or at the conditions of the dedicated receiver.(iv) To calculate emissions when a vessel is equipped with a process condenser or a control condenser, each entity must use the procedures in § 63.1257(d)(3)(i)(B) of this chapter, except as follows. Each entity must determine the flow rate of gas (or volume of gas), partial pressures of condensables, temperature (T), and controlled substance molecular weight (MWcontrolled substance) at the exit temperature and exit pressure conditions of the condenser or at the conditions of the dedicated receiver. Each entity must assume that all of the components contained in the condenser exit vent stream are in equilibrium with the same components in the exit condensate stream (except for noncondensables). Each entity must perform a material balance for each component, if the condensate receiver composition is not known. For the emissions from purging, the term for time, t, must be used in equation 12 to § 63.1257(d)(2)(i)(B) of this chapter. Emissions from empty vessel purging must be calculated using equation 36 to § 63.1257(d)(2)(i)(H) of this chapter and the exit temperature and exit pressure conditions of the condenser or the conditions of the dedicated receiver.(3) Commercial software products that follow chemical engineering principles (e.g., including the calculation methodologies in paragraphs (c)(1)(i)(A)(1) and (2) of this section).