§761.45. Marking formats. — Inbound Citations

40 C.F.R. § 761.45

Cited by 3 regulations in release Current.

Citations to §761.45(a)

  • (A) PCBs are authorized for use, at concentrations ≥50 ppm, in natural gas pipeline systems owned or operated by a seller or distributor of natural gas, if the owner or operator:
    (1) Submits to EPA, upon request, a written description of the general nature and location of PCBs ≥50 ppm in their natural gas pipeline system. Each written description shall be submitted to the EPA Regional Administrator having jurisdiction over the segment or component of the system (or the Director, National Program Chemicals Division, Office of Pollution Prevention and Toxics, if the system is contaminated in more than one region).
    (2) Within 120 days after discovery of PCBs ≥50 ppm in natural gas pipeline systems, or by December 28, 1998, whichever is later, characterizes the extent of PCB contamination by collecting and analyzing samples to identify the upstream and downstream end points of the segment or component where PCBs ≥50 ppm were discovered.
    (3) Within 120 days of characterization of the extent of PCB contamination, or by December 28, 1998, whichever is later, samples and analyzes all potential sources of introduction of PCBs into the natural gas pipeline system for PCBs ≥50 ppm. Potential sources include natural gas compressors, natural gas scrubbers, natural gas filters, and interconnects where natural gas is received upstream from the most downstream sampling point where PCBs ≥50 ppm were detected; potential sources exclude valves, drips, or other small liquid condensate collection points.
    (4) Within 1 year of characterization of the extent of PCB contamination, reduces all demonstrated sources of PCBs ≥50 ppm to <50 ppm, or removes such sources from the natural gas pipeline system; or implements other engineering measures or methods to reduce PCB levels to <50 ppm and to prevent further introduction of PCBs ≥50 ppm into the natural gas pipeline system (e.g., pigging, decontamination, in-line filtration).
    (5) Repeats sampling and analysis at least annually where PCBs are ≥50 ppm, until sampling results indicate the natural gas pipeline segment or component is <50 ppm PCB in two successive samples with a minimum interval between samples of 180 days.
    (6) Marks aboveground sources of PCB liquids in natural gas pipeline systems with the ML Mark in accordance with § 761.45(a), where such sources have been demonstrated through historical data or recent sampling to contain PCBs ≥50 ppm.
  • (a) Each of the following items in existence on or after July 1, 1978 shall be marked as illustrated in Figure 1 in § 761.45(a): The mark illustrated in Figure 1 is referred to as ML throughout this subpart.
    (1) PCB Containers;
    (2) PCB Transformers at the time of manufacture, at the time of distribution in commerce if not already marked, and at the time of removal from use if not already marked. [Marking of PCB-Contaminated Electrical Equipment is not required];
    (3) PCB Large High Voltage Capacitors at the time of manufacture, at the time of distribution in commerce if not already marked, and at the time of removal from use if not already marked;
    (4) Equipment containing a PCB Transformer or a PCB Large High Voltage Capacitor at the time of manufacture, at the time of distribution in commerce if not already marked, and at the time of removal of the equipment from use if not already marked;
    (5) PCB Large Low Voltage Capacitors at the time of removal from use (see also paragraph (k) of this section).
    (7) Hydraulic systems using PCB hydraulic fluid (See also paragraph (e) of this section);
    (8) Heat transfer systems (other than PCB Transformers) using PCBs (See also paragraph (e) of this section);
    (9) PCB Article Containers containing articles or equipment that must be marked under paragraphs (a) (1) through (8) of this section;

Citations to §761.45(b)