§76.12. Phase I NO X compliance extension. — Inbound Citations
40 C.F.R. § 76.12
Statutory Authority
Cited by 1 regulation in release Current.
Citations to 40 C.F.R. § 76.12 as a whole
-
(a) Beginning January 1, 1996, or for a unit subject to section 404(d) of the Act, the date on which the unit is required to meet Acid Rain emission reduction requirements for SO2, the owner or operator of a Phase I coal-fired utility unit with a tangentially fired boiler or a dry bottom wall-fired boiler (other than units applying cell burner technology) shall not discharge, or allow to be discharged, emissions of NOX to the atmosphere in excess of the following limits, except as provided in paragraphs (c) or (e) of this section or in § 76.10, 76.11, or 76.12:(1) 0.45 lb/mmBtu of heat input on an annual average basis for tangentially fired boilers.(2) 0.50 lb/mmBtu of heat input on an annual average basis for dry bottom wall-fired boilers (other than units applying cell burner technology).