§75.59. Certification, quality assurance, and quality control record provisions. — Inbound Citations

40 C.F.R. § 75.59

Cited by 186 regulations in release Current.

Citations to 40 C.F.R. § 75.59 as a whole

  • (b) No owner or operator of an affected unit shall operate the unit without complying with the requirements of §§ 75.2 through 75.75 and appendices A through G to this part.
  • (4) The certification test data and information required in § 75.59 for tests required under § 75.20, beginning with the date of the first certification test performed, the quality assurance and quality control data and information required in § 75.59 for tests, and the quality assurance/quality control plan required under § 75.21 and appendix B to this part, beginning with the date of provisional certification;
  • (48) ASTM D7036-04, Standard Practice for Competence of Air Emission Testing Bodies, for § 75.21, § 75.59, and appendix A to this part.
  • (ii) The results of the test(s) required by § 75.20, including the type of test conducted, testing date, information required by § 75.59, and the results of any failed tests that affect data validation.
  • (2) The information and hourly data required in § 75.53 and §§ 75.57 through 75.59, excluding the following:
    (i) Descriptions of adjustments, corrective action, and maintenance;
    (ii) Information which is incompatible with electronic reporting (e.g., field data sheets, lab analyses, quality control plan);
    (iii) Opacity data listed in or § 75.57(f), and in § 75.59(a)(8);
    (iv) For units with SO2 or NOX add-on emission controls that do not elect to use the approved site-specific parametric monitoring procedures for calculation of substitute data, the information in § 75.58(b)(3);
    (v) [Reserved]
    (vi) Information required by § 75.57(h) concerning the causes of any missing data periods and the actions taken to cure such causes;
    (vii) Hardcopy monitoring plan information required by § 75.53 and hardcopy test data and results required by § 75.59;
    (viii) Records of flow monitor and moisture monitoring system polynomial equations, coefficients, or “K” factors required by § 75.59(a)(5)(vi) or § 75.59(a)(5)(vii);
    (ix) Daily fuel sampling information required by § 75.58(c)(3)(i) for units using assumed values under appendix D;
    (x) Information required by §§ 75.59(b)(1)(vi), (vii), (viii), (ix), and (xiii), and (b)(2)(iii) and (iv) concerning fuel flowmeter accuracy tests and transmitter/transducer accuracy tests;
    (xi) Stratification test results required as part of the RATA supplementary records under § 75.59(a)(7);
    (xii) Data and results of RATAs that are aborted or invalidated due to problems with the reference method or operational problems with the unit and data and results of linearity checks that are aborted or invalidated due to problems unrelated to monitor performance; and
    (xiii) Supplementary RATA information required under § 75.59(a)(7), except that:
    (A) The applicable data elements under § 75.59(a)(7)(ii)(A) through (T) and under § 75.59(a)(7)(iii)(A) through (M) shall be reported for flow RATAs at circular or rectangular stacks (or ducts) in which angular compensation for yaw and/or pitch angles is used (i.e., Method 2F or 2G in appendices A-1 and A-2 to part 60 of this chapter), with or without wall effects adjustments;
    (B) The applicable data elements under § 75.59(a)(7)(ii)(A) through (T) and under § 75.59(a)(7)(iii)(A) through (M) shall be reported for any flow RATA run at a circular stack in which Method 2 in appendices A-1 and A-2 to part 60 of this chapter is used and a wall effects adjustment factor is determined by direct measurement;
    (C) The data under § 75.59(a)(7)(ii)(T) shall be reported for all flow RATAs at circular stacks in which Method 2 in appendices A-1 and A-2 to part 60 of this chapter is used and a default wall effects adjustment factor is applied; and
    (D) The data under § 75.59(a)(7)(ix)(A) through (F) shall be reported for all flow RATAs at rectangular stacks or ducts in which Method 2 in appendices A-1 and A-2 to part 60 of this chapter is used and a wall effects adjustment factor is applied.
  • (b) The owner or operator of any affected unit shall record the applicable information in § 75.59 for each affected unit or group of units monitored at a common stack and each non-affected unit under § 75.72(b)(2)(ii).

Citations to §75.59(a)

Citations to §75.59(a)(1)

  • (5) The daily calibration error test and daily interference check information required in § 75.59(a)(1) and (a)(2) must always be included in the electronic quarterly emissions report. All other certification, quality assurance, and quality control information in § 75.59 that is not excluded from electronic reporting under paragraph (a)(2) or (a)(7) of this section shall be submitted separately, either prior to or concurrent with the submittal of the relevant electronic quarterly emissions report. However, reporting of the information in § 75.59(a)(9)(x) is not required until September 26, 2011, and reporting of the information in § 75.59(a)(15), (b)(6), and (d)(4) is not required until March 27, 2012.

Citations to §75.59(a)(2)

  • (5) The daily calibration error test and daily interference check information required in § 75.59(a)(1) and (a)(2) must always be included in the electronic quarterly emissions report. All other certification, quality assurance, and quality control information in § 75.59 that is not excluded from electronic reporting under paragraph (a)(2) or (a)(7) of this section shall be submitted separately, either prior to or concurrent with the submittal of the relevant electronic quarterly emissions report. However, reporting of the information in § 75.59(a)(9)(x) is not required until September 26, 2011, and reporting of the information in § 75.59(a)(15), (b)(6), and (d)(4) is not required until March 27, 2012.

Citations to §75.59(a)(5)

Citations to §75.59(a)(5)(vi)

Citations to §75.59(a)(5)(vii)

Citations to §75.59(a)(7)

Citations to §75.59(a)(7)(i)

  • (7) In addition to the information in paragraph (a)(5) of this section, the owner or operator shall record, for each relative accuracy test audit, supporting information sufficient to substantiate compliance with all applicable sections and appendices in this part. Unless otherwise specified in this part or in an applicable test method, the information in paragraphs (a)(7)(i) through (a)(7)(vi) of this section may be recorded either in hard copy format, electronic format or a combination of the two, and the owner or operator shall maintain this information in a format suitable for inspection and audit purposes. This RATA supporting information shall include, but shall not be limited to, the following data elements:
    (i) For each RATA using Reference Method 2 (or its allowable alternatives) in appendix A to part 60 of this chapter to determine volumetric flow rate:
    (A) Information indicating whether or not the location meets requirements of Method 1 in appendix A to part 60 of this chapter; and
    (ii) For each run of each RATA using Reference Method 2 (or its allowable alternatives in appendix A to part 60 of this chapter) to determine volumetric flow rate, record the following data elements (as applicable to the measurement method used):
    (A) Operating level (low, mid, high, or normal, as appropriate);
    (B) Number of reference method traverse points;
    (C) Average stack gas temperature (°F);
    (D) Barometric pressure at test port (inches of mercury);
    (E) Stack static pressure (inches of H2O);
    (F) Absolute stack gas pressure (inches of mercury);
    (G) Percent CO2 and O2 in the stack gas, dry basis;
    (H) CO2 and O2 reference method used;
    (I) Moisture content of stack gas (percent H2O);
    (J) Molecular weight of stack gas, dry basis (lb/lb-mole);
    (K) Molecular weight of stack gas, wet basis (lb/lb-mole);
    (L) Stack diameter (or equivalent diameter) at the test port (ft);
    (M) Average square root of velocity head of stack gas (inches of H2O) for the run;
    (N) Stack or duct cross-sectional area at test port (ft 2);
    (O) Average velocity (ft/sec);
    (P) Average stack flow rate, adjusted, if applicable, for wall effects (scfh, wet basis);
    (Q) Flow rate reference method used;
    (R) Average velocity, adjusted for wall effects;
    (S) Calculated (site-specific) wall effects adjustment factor determined during the run, and, if different, the wall effects adjustment factor used in the calculations; and
    (iii) For each traverse point of each run of each RATA using Reference Method 2 (or its allowable alternatives in appendix A to part 60 of this chapter) to determine volumetric flow rate, record the following data elements (as applicable to the measurement method used):
    (A) Reference method probe type;
    (B) Pressure measurement device type;
    (C) Traverse point ID;
    (D) Probe or pitot tube calibration coefficient;
    (E) Date of latest probe or pitot tube calibration;
    (F) Average velocity differential pressure at traverse point (inches of H2O) or the average of the square roots of the velocity differential pressures at the traverse point ((inches of H2O) 1/2);
    (G) TS, stack temperature at the traverse point (°F);
    (H) Composite (wall effects) traverse point identifier;
    (I) Number of points included in composite traverse point;
    (J) Yaw angle of flow at traverse point (degrees);
    (K) Pitch angle of flow at traverse point (degrees);
    (L) Calculated velocity at traverse point both accounting and not accounting for wall effects (ft/sec); and
    (iv) For each RATA using Method 6C, 7E, or 3A in appendix A to part 60 of this chapter to determine SO2, NOX, CO2, or O2 concentration:
    (A) Pollutant or diluent gas being measured;
    (B) Span of reference method analyzer;
    (C) Type of reference method system (e.g., extractive or dilution type);
    (D) Reference method dilution factor (dilution type systems, only);
    (E) Reference gas concentrations (zero, mid, and high gas levels) used for the 3-point pre-test analyzer calibration error test (or, for dilution type reference method systems, for the 3-point pre-test system calibration error test) and for any subsequent recalibrations;
    (F) Analyzer responses to the zero-, mid-, and high-level calibration gases during the 3-point pre-test analyzer (or system) calibration error test and during any subsequent recalibration(s);
    (G) Analyzer calibration error at each gas level (zero, mid, and high) for the 3-point pre-test analyzer (or system) calibration error test and for any subsequent recalibration(s) (percent of span value);
    (H) Upscale gas concentration (mid or high gas level) used for each pre-run or post-run system bias check or (for dilution type reference method systems) for each pre-run or post-run system calibration error check;
    (I) Analyzer response to the calibration gas for each pre-run or post-run system bias (or system calibration error) check;
    (J) The arithmetic average of the analyzer responses to the zero-level gas, for each pair of pre- and post-run system bias (or system calibration error) checks;
    (K) The arithmetic average of the analyzer responses to the upscale calibration gas, for each pair of pre- and post-run system bias (or system calibration error) checks;
    (L) The results of each pre-run and each post-run system bias (or system calibration error) check using the zero-level gas (percentage of span value);
    (M) The results of each pre-run and each post-run system bias (or system calibration error) check using the upscale calibration gas (percentage of span value);
    (N) Calibration drift and zero drift of analyzer during each RATA run (percentage of span value);
    (O) Moisture basis of the reference method analysis;
    (P) Moisture content of stack gas, in percent, during each test run (if needed to convert to moisture basis of CEMS being tested);
    (Q) Unadjusted (raw) average pollutant or diluent gas concentration for each run;
    (R) Average pollutant or diluent gas concentration for each run, corrected for calibration bias (or calibration error) and, if applicable, corrected for moisture;
    (S) The F-factor used to convert reference method data to units of lb/mmBtu (if applicable);
    (T) Date(s) of the latest analyzer interference test(s);
    (U) Results of the latest analyzer interference test(s);
    (V) Date of the latest NO2 to NO conversion test (Method 7E only);
    (W) Results of the latest NO2 to NO conversion test (Method 7E only); and
    (X) For each calibration gas cylinder used during each RATA, record the cylinder gas vendor, cylinder number, expiration date, pollutant(s) in the cylinder, and certified gas concentration(s).
    (v) For each test run of each moisture determination using Method 4 in appendix A to part 60 of this chapter (or its allowable alternatives), whether the determination is made to support a gas RATA, to support a flow RATA, or to quality assure the data from a continuous moisture monitoring system, record the following data elements (as applicable to the moisture measurement method used):
    (A) Test number;
    (B) Run number;
    (C) The beginning date, hour, and minute of the run;
    (D) The ending date, hour, and minute of the run;
    (E) Unit operating level (low, mid, high, or normal, as appropriate);
    (F) Moisture measurement method;
    (G) Volume of H2O collected in the impingers (ml);
    (H) Mass of H2O collected in the silica gel (g);
    (I) Dry gas meter calibration factor;
    (J) Average dry gas meter temperature (°F);
    (K) Barometric pressure (inches of mercury);
    (L) Differential pressure across the orifice meter (inches of H2O);
    (M) Initial and final dry gas meter readings (ft 3);
    (N) Total sample gas volume, corrected to standard conditions (dscf); and
    (vi) The raw data and calculated results for any stratification tests performed in accordance with sections 6.5.6.1 through 6.5.6.3 of appendix A to this part.
    (vii) [Reserved]
    (viii) [Reserved]
    (ix) For a unit with a flow monitor installed on a rectangular stack or duct, if a site-specific default or measured wall effects adjustment factor (WAF) is used to correct the stack gas volumetric flow rate data to account for velocity decay near the stack or duct wall, the owner or operator shall keep records of the following for each flow RATA performed with EPA Method 2 in appendices A-1 and A-2 to part 60 of this chapter, subsequent to the WAF determination:
    (A) Monitoring system ID;
    (B) Test number;
    (C) Operating level;
    (D) RATA end date and time;
    (E) Number of Method 1 traverse points; and
    (F) Wall effects adjustment factor (WAF), to the nearest 0.0001.
  • (xii) Supplementary RATA information required under § 75.59(a)(7)(i) through § 75.59(a)(7)(v), except that:
    (A) The applicable data elements under § 75.59(a)(7)(ii)(A) through (T) and under § 75.59(a)(7)(iii)(A) through (M) shall be reported for flow RATAs at circular or rectangular stacks (or ducts) in which angular compensation for yaw and/or pitch angles is used (i.e., Method 2F or 2G in appendices A-1 and A-2 to part 60 of this chapter), with or without wall effects adjustments;
    (B) The applicable data elements under § 75.59(a)(7)(ii)(A) through (T) and under § 75.59(a)(7)(iii)(A) through (M) shall be reported for any flow RATA run at a circular stack in which Method 2 in appendices A-1 and A-2 to part 60 of this chapter is used and a wall effects adjustment factor is determined by direct measurement;
    (C) The data under § 75.59(a)(7)(ii)(T) shall be reported for all flow RATAs at circular stacks in which Method 2 in appendices A-1 and A-2 to part 60 of this chapter is used and a default wall effects adjustment factor is applied; and
    (D) The data under § 75.59(a)(7)(ix)(A) through (F) shall be reported for all flow RATAs at rectangular stacks or ducts in which Method 2 in appendices A-1 and A-2 to part 60 of this chapter is used and a wall effects adjustment factor is applied; and

Citations to §75.59(a)(7)(ii)

  • (7) In addition to the information in paragraph (a)(5) of this section, the owner or operator shall record, for each relative accuracy test audit, supporting information sufficient to substantiate compliance with all applicable sections and appendices in this part. Unless otherwise specified in this part or in an applicable test method, the information in paragraphs (a)(7)(i) through (a)(7)(vi) of this section may be recorded either in hard copy format, electronic format or a combination of the two, and the owner or operator shall maintain this information in a format suitable for inspection and audit purposes. This RATA supporting information shall include, but shall not be limited to, the following data elements:
    (i) For each RATA using Reference Method 2 (or its allowable alternatives) in appendix A to part 60 of this chapter to determine volumetric flow rate:
    (A) Information indicating whether or not the location meets requirements of Method 1 in appendix A to part 60 of this chapter; and
    (ii) For each run of each RATA using Reference Method 2 (or its allowable alternatives in appendix A to part 60 of this chapter) to determine volumetric flow rate, record the following data elements (as applicable to the measurement method used):
    (A) Operating level (low, mid, high, or normal, as appropriate);
    (B) Number of reference method traverse points;
    (C) Average stack gas temperature (°F);
    (D) Barometric pressure at test port (inches of mercury);
    (E) Stack static pressure (inches of H2O);
    (F) Absolute stack gas pressure (inches of mercury);
    (G) Percent CO2 and O2 in the stack gas, dry basis;
    (H) CO2 and O2 reference method used;
    (I) Moisture content of stack gas (percent H2O);
    (J) Molecular weight of stack gas, dry basis (lb/lb-mole);
    (K) Molecular weight of stack gas, wet basis (lb/lb-mole);
    (L) Stack diameter (or equivalent diameter) at the test port (ft);
    (M) Average square root of velocity head of stack gas (inches of H2O) for the run;
    (N) Stack or duct cross-sectional area at test port (ft 2);
    (O) Average velocity (ft/sec);
    (P) Average stack flow rate, adjusted, if applicable, for wall effects (scfh, wet basis);
    (Q) Flow rate reference method used;
    (R) Average velocity, adjusted for wall effects;
    (S) Calculated (site-specific) wall effects adjustment factor determined during the run, and, if different, the wall effects adjustment factor used in the calculations; and
    (iii) For each traverse point of each run of each RATA using Reference Method 2 (or its allowable alternatives in appendix A to part 60 of this chapter) to determine volumetric flow rate, record the following data elements (as applicable to the measurement method used):
    (A) Reference method probe type;
    (B) Pressure measurement device type;
    (C) Traverse point ID;
    (D) Probe or pitot tube calibration coefficient;
    (E) Date of latest probe or pitot tube calibration;
    (F) Average velocity differential pressure at traverse point (inches of H2O) or the average of the square roots of the velocity differential pressures at the traverse point ((inches of H2O) 1/2);
    (G) TS, stack temperature at the traverse point (°F);
    (H) Composite (wall effects) traverse point identifier;
    (I) Number of points included in composite traverse point;
    (J) Yaw angle of flow at traverse point (degrees);
    (K) Pitch angle of flow at traverse point (degrees);
    (L) Calculated velocity at traverse point both accounting and not accounting for wall effects (ft/sec); and
    (iv) For each RATA using Method 6C, 7E, or 3A in appendix A to part 60 of this chapter to determine SO2, NOX, CO2, or O2 concentration:
    (A) Pollutant or diluent gas being measured;
    (B) Span of reference method analyzer;
    (C) Type of reference method system (e.g., extractive or dilution type);
    (D) Reference method dilution factor (dilution type systems, only);
    (E) Reference gas concentrations (zero, mid, and high gas levels) used for the 3-point pre-test analyzer calibration error test (or, for dilution type reference method systems, for the 3-point pre-test system calibration error test) and for any subsequent recalibrations;
    (F) Analyzer responses to the zero-, mid-, and high-level calibration gases during the 3-point pre-test analyzer (or system) calibration error test and during any subsequent recalibration(s);
    (G) Analyzer calibration error at each gas level (zero, mid, and high) for the 3-point pre-test analyzer (or system) calibration error test and for any subsequent recalibration(s) (percent of span value);
    (H) Upscale gas concentration (mid or high gas level) used for each pre-run or post-run system bias check or (for dilution type reference method systems) for each pre-run or post-run system calibration error check;
    (I) Analyzer response to the calibration gas for each pre-run or post-run system bias (or system calibration error) check;
    (J) The arithmetic average of the analyzer responses to the zero-level gas, for each pair of pre- and post-run system bias (or system calibration error) checks;
    (K) The arithmetic average of the analyzer responses to the upscale calibration gas, for each pair of pre- and post-run system bias (or system calibration error) checks;
    (L) The results of each pre-run and each post-run system bias (or system calibration error) check using the zero-level gas (percentage of span value);
    (M) The results of each pre-run and each post-run system bias (or system calibration error) check using the upscale calibration gas (percentage of span value);
    (N) Calibration drift and zero drift of analyzer during each RATA run (percentage of span value);
    (O) Moisture basis of the reference method analysis;
    (P) Moisture content of stack gas, in percent, during each test run (if needed to convert to moisture basis of CEMS being tested);
    (Q) Unadjusted (raw) average pollutant or diluent gas concentration for each run;
    (R) Average pollutant or diluent gas concentration for each run, corrected for calibration bias (or calibration error) and, if applicable, corrected for moisture;
    (S) The F-factor used to convert reference method data to units of lb/mmBtu (if applicable);
    (T) Date(s) of the latest analyzer interference test(s);
    (U) Results of the latest analyzer interference test(s);
    (V) Date of the latest NO2 to NO conversion test (Method 7E only);
    (W) Results of the latest NO2 to NO conversion test (Method 7E only); and
    (X) For each calibration gas cylinder used during each RATA, record the cylinder gas vendor, cylinder number, expiration date, pollutant(s) in the cylinder, and certified gas concentration(s).
    (v) For each test run of each moisture determination using Method 4 in appendix A to part 60 of this chapter (or its allowable alternatives), whether the determination is made to support a gas RATA, to support a flow RATA, or to quality assure the data from a continuous moisture monitoring system, record the following data elements (as applicable to the moisture measurement method used):
    (A) Test number;
    (B) Run number;
    (C) The beginning date, hour, and minute of the run;
    (D) The ending date, hour, and minute of the run;
    (E) Unit operating level (low, mid, high, or normal, as appropriate);
    (F) Moisture measurement method;
    (G) Volume of H2O collected in the impingers (ml);
    (H) Mass of H2O collected in the silica gel (g);
    (I) Dry gas meter calibration factor;
    (J) Average dry gas meter temperature (°F);
    (K) Barometric pressure (inches of mercury);
    (L) Differential pressure across the orifice meter (inches of H2O);
    (M) Initial and final dry gas meter readings (ft 3);
    (N) Total sample gas volume, corrected to standard conditions (dscf); and
    (vi) The raw data and calculated results for any stratification tests performed in accordance with sections 6.5.6.1 through 6.5.6.3 of appendix A to this part.
    (vii) [Reserved]
    (viii) [Reserved]
    (ix) For a unit with a flow monitor installed on a rectangular stack or duct, if a site-specific default or measured wall effects adjustment factor (WAF) is used to correct the stack gas volumetric flow rate data to account for velocity decay near the stack or duct wall, the owner or operator shall keep records of the following for each flow RATA performed with EPA Method 2 in appendices A-1 and A-2 to part 60 of this chapter, subsequent to the WAF determination:
    (A) Monitoring system ID;
    (B) Test number;
    (C) Operating level;
    (D) RATA end date and time;
    (E) Number of Method 1 traverse points; and
    (F) Wall effects adjustment factor (WAF), to the nearest 0.0001.

Citations to §75.59(a)(7)(ii)(A)

Citations to §75.59(a)(7)(ii)(B)

Citations to §75.59(a)(7)(ii)(C)

Citations to §75.59(a)(7)(ii)(D)

Citations to §75.59(a)(7)(ii)(E)

Citations to §75.59(a)(7)(ii)(F)

Citations to §75.59(a)(7)(ii)(G)

Citations to §75.59(a)(7)(ii)(H)

Citations to §75.59(a)(7)(ii)(I)

Citations to §75.59(a)(7)(ii)(J)

Citations to §75.59(a)(7)(ii)(K)

Citations to §75.59(a)(7)(ii)(L)

Citations to §75.59(a)(7)(ii)(M)

Citations to §75.59(a)(7)(ii)(N)

Citations to §75.59(a)(7)(ii)(O)

Citations to §75.59(a)(7)(ii)(P)

Citations to §75.59(a)(7)(ii)(Q)

Citations to §75.59(a)(7)(ii)(R)

Citations to §75.59(a)(7)(ii)(S)

Citations to §75.59(a)(7)(ii)(T)

Citations to §75.59(a)(7)(iii)

  • (7) In addition to the information in paragraph (a)(5) of this section, the owner or operator shall record, for each relative accuracy test audit, supporting information sufficient to substantiate compliance with all applicable sections and appendices in this part. Unless otherwise specified in this part or in an applicable test method, the information in paragraphs (a)(7)(i) through (a)(7)(vi) of this section may be recorded either in hard copy format, electronic format or a combination of the two, and the owner or operator shall maintain this information in a format suitable for inspection and audit purposes. This RATA supporting information shall include, but shall not be limited to, the following data elements:
    (i) For each RATA using Reference Method 2 (or its allowable alternatives) in appendix A to part 60 of this chapter to determine volumetric flow rate:
    (A) Information indicating whether or not the location meets requirements of Method 1 in appendix A to part 60 of this chapter; and
    (ii) For each run of each RATA using Reference Method 2 (or its allowable alternatives in appendix A to part 60 of this chapter) to determine volumetric flow rate, record the following data elements (as applicable to the measurement method used):
    (A) Operating level (low, mid, high, or normal, as appropriate);
    (B) Number of reference method traverse points;
    (C) Average stack gas temperature (°F);
    (D) Barometric pressure at test port (inches of mercury);
    (E) Stack static pressure (inches of H2O);
    (F) Absolute stack gas pressure (inches of mercury);
    (G) Percent CO2 and O2 in the stack gas, dry basis;
    (H) CO2 and O2 reference method used;
    (I) Moisture content of stack gas (percent H2O);
    (J) Molecular weight of stack gas, dry basis (lb/lb-mole);
    (K) Molecular weight of stack gas, wet basis (lb/lb-mole);
    (L) Stack diameter (or equivalent diameter) at the test port (ft);
    (M) Average square root of velocity head of stack gas (inches of H2O) for the run;
    (N) Stack or duct cross-sectional area at test port (ft 2);
    (O) Average velocity (ft/sec);
    (P) Average stack flow rate, adjusted, if applicable, for wall effects (scfh, wet basis);
    (Q) Flow rate reference method used;
    (R) Average velocity, adjusted for wall effects;
    (S) Calculated (site-specific) wall effects adjustment factor determined during the run, and, if different, the wall effects adjustment factor used in the calculations; and
    (iii) For each traverse point of each run of each RATA using Reference Method 2 (or its allowable alternatives in appendix A to part 60 of this chapter) to determine volumetric flow rate, record the following data elements (as applicable to the measurement method used):
    (A) Reference method probe type;
    (B) Pressure measurement device type;
    (C) Traverse point ID;
    (D) Probe or pitot tube calibration coefficient;
    (E) Date of latest probe or pitot tube calibration;
    (F) Average velocity differential pressure at traverse point (inches of H2O) or the average of the square roots of the velocity differential pressures at the traverse point ((inches of H2O) 1/2);
    (G) TS, stack temperature at the traverse point (°F);
    (H) Composite (wall effects) traverse point identifier;
    (I) Number of points included in composite traverse point;
    (J) Yaw angle of flow at traverse point (degrees);
    (K) Pitch angle of flow at traverse point (degrees);
    (L) Calculated velocity at traverse point both accounting and not accounting for wall effects (ft/sec); and
    (iv) For each RATA using Method 6C, 7E, or 3A in appendix A to part 60 of this chapter to determine SO2, NOX, CO2, or O2 concentration:
    (A) Pollutant or diluent gas being measured;
    (B) Span of reference method analyzer;
    (C) Type of reference method system (e.g., extractive or dilution type);
    (D) Reference method dilution factor (dilution type systems, only);
    (E) Reference gas concentrations (zero, mid, and high gas levels) used for the 3-point pre-test analyzer calibration error test (or, for dilution type reference method systems, for the 3-point pre-test system calibration error test) and for any subsequent recalibrations;
    (F) Analyzer responses to the zero-, mid-, and high-level calibration gases during the 3-point pre-test analyzer (or system) calibration error test and during any subsequent recalibration(s);
    (G) Analyzer calibration error at each gas level (zero, mid, and high) for the 3-point pre-test analyzer (or system) calibration error test and for any subsequent recalibration(s) (percent of span value);
    (H) Upscale gas concentration (mid or high gas level) used for each pre-run or post-run system bias check or (for dilution type reference method systems) for each pre-run or post-run system calibration error check;
    (I) Analyzer response to the calibration gas for each pre-run or post-run system bias (or system calibration error) check;
    (J) The arithmetic average of the analyzer responses to the zero-level gas, for each pair of pre- and post-run system bias (or system calibration error) checks;
    (K) The arithmetic average of the analyzer responses to the upscale calibration gas, for each pair of pre- and post-run system bias (or system calibration error) checks;
    (L) The results of each pre-run and each post-run system bias (or system calibration error) check using the zero-level gas (percentage of span value);
    (M) The results of each pre-run and each post-run system bias (or system calibration error) check using the upscale calibration gas (percentage of span value);
    (N) Calibration drift and zero drift of analyzer during each RATA run (percentage of span value);
    (O) Moisture basis of the reference method analysis;
    (P) Moisture content of stack gas, in percent, during each test run (if needed to convert to moisture basis of CEMS being tested);
    (Q) Unadjusted (raw) average pollutant or diluent gas concentration for each run;
    (R) Average pollutant or diluent gas concentration for each run, corrected for calibration bias (or calibration error) and, if applicable, corrected for moisture;
    (S) The F-factor used to convert reference method data to units of lb/mmBtu (if applicable);
    (T) Date(s) of the latest analyzer interference test(s);
    (U) Results of the latest analyzer interference test(s);
    (V) Date of the latest NO2 to NO conversion test (Method 7E only);
    (W) Results of the latest NO2 to NO conversion test (Method 7E only); and
    (X) For each calibration gas cylinder used during each RATA, record the cylinder gas vendor, cylinder number, expiration date, pollutant(s) in the cylinder, and certified gas concentration(s).
    (v) For each test run of each moisture determination using Method 4 in appendix A to part 60 of this chapter (or its allowable alternatives), whether the determination is made to support a gas RATA, to support a flow RATA, or to quality assure the data from a continuous moisture monitoring system, record the following data elements (as applicable to the moisture measurement method used):
    (A) Test number;
    (B) Run number;
    (C) The beginning date, hour, and minute of the run;
    (D) The ending date, hour, and minute of the run;
    (E) Unit operating level (low, mid, high, or normal, as appropriate);
    (F) Moisture measurement method;
    (G) Volume of H2O collected in the impingers (ml);
    (H) Mass of H2O collected in the silica gel (g);
    (I) Dry gas meter calibration factor;
    (J) Average dry gas meter temperature (°F);
    (K) Barometric pressure (inches of mercury);
    (L) Differential pressure across the orifice meter (inches of H2O);
    (M) Initial and final dry gas meter readings (ft 3);
    (N) Total sample gas volume, corrected to standard conditions (dscf); and
    (vi) The raw data and calculated results for any stratification tests performed in accordance with sections 6.5.6.1 through 6.5.6.3 of appendix A to this part.
    (vii) [Reserved]
    (viii) [Reserved]
    (ix) For a unit with a flow monitor installed on a rectangular stack or duct, if a site-specific default or measured wall effects adjustment factor (WAF) is used to correct the stack gas volumetric flow rate data to account for velocity decay near the stack or duct wall, the owner or operator shall keep records of the following for each flow RATA performed with EPA Method 2 in appendices A-1 and A-2 to part 60 of this chapter, subsequent to the WAF determination:
    (A) Monitoring system ID;
    (B) Test number;
    (C) Operating level;
    (D) RATA end date and time;
    (E) Number of Method 1 traverse points; and
    (F) Wall effects adjustment factor (WAF), to the nearest 0.0001.

Citations to §75.59(a)(7)(iii)(A)

Citations to §75.59(a)(7)(iii)(B)

Citations to §75.59(a)(7)(iii)(C)

Citations to §75.59(a)(7)(iii)(D)

Citations to §75.59(a)(7)(iii)(E)

Citations to §75.59(a)(7)(iii)(F)

Citations to §75.59(a)(7)(iii)(G)

Citations to §75.59(a)(7)(iii)(H)

Citations to §75.59(a)(7)(iii)(I)

Citations to §75.59(a)(7)(iii)(J)

Citations to §75.59(a)(7)(iii)(K)

Citations to §75.59(a)(7)(iii)(L)

Citations to §75.59(a)(7)(iii)(M)

Citations to §75.59(a)(7)(iv)

  • (7) In addition to the information in paragraph (a)(5) of this section, the owner or operator shall record, for each relative accuracy test audit, supporting information sufficient to substantiate compliance with all applicable sections and appendices in this part. Unless otherwise specified in this part or in an applicable test method, the information in paragraphs (a)(7)(i) through (a)(7)(vi) of this section may be recorded either in hard copy format, electronic format or a combination of the two, and the owner or operator shall maintain this information in a format suitable for inspection and audit purposes. This RATA supporting information shall include, but shall not be limited to, the following data elements:
    (i) For each RATA using Reference Method 2 (or its allowable alternatives) in appendix A to part 60 of this chapter to determine volumetric flow rate:
    (A) Information indicating whether or not the location meets requirements of Method 1 in appendix A to part 60 of this chapter; and
    (ii) For each run of each RATA using Reference Method 2 (or its allowable alternatives in appendix A to part 60 of this chapter) to determine volumetric flow rate, record the following data elements (as applicable to the measurement method used):
    (A) Operating level (low, mid, high, or normal, as appropriate);
    (B) Number of reference method traverse points;
    (C) Average stack gas temperature (°F);
    (D) Barometric pressure at test port (inches of mercury);
    (E) Stack static pressure (inches of H2O);
    (F) Absolute stack gas pressure (inches of mercury);
    (G) Percent CO2 and O2 in the stack gas, dry basis;
    (H) CO2 and O2 reference method used;
    (I) Moisture content of stack gas (percent H2O);
    (J) Molecular weight of stack gas, dry basis (lb/lb-mole);
    (K) Molecular weight of stack gas, wet basis (lb/lb-mole);
    (L) Stack diameter (or equivalent diameter) at the test port (ft);
    (M) Average square root of velocity head of stack gas (inches of H2O) for the run;
    (N) Stack or duct cross-sectional area at test port (ft 2);
    (O) Average velocity (ft/sec);
    (P) Average stack flow rate, adjusted, if applicable, for wall effects (scfh, wet basis);
    (Q) Flow rate reference method used;
    (R) Average velocity, adjusted for wall effects;
    (S) Calculated (site-specific) wall effects adjustment factor determined during the run, and, if different, the wall effects adjustment factor used in the calculations; and
    (iii) For each traverse point of each run of each RATA using Reference Method 2 (or its allowable alternatives in appendix A to part 60 of this chapter) to determine volumetric flow rate, record the following data elements (as applicable to the measurement method used):
    (A) Reference method probe type;
    (B) Pressure measurement device type;
    (C) Traverse point ID;
    (D) Probe or pitot tube calibration coefficient;
    (E) Date of latest probe or pitot tube calibration;
    (F) Average velocity differential pressure at traverse point (inches of H2O) or the average of the square roots of the velocity differential pressures at the traverse point ((inches of H2O) 1/2);
    (G) TS, stack temperature at the traverse point (°F);
    (H) Composite (wall effects) traverse point identifier;
    (I) Number of points included in composite traverse point;
    (J) Yaw angle of flow at traverse point (degrees);
    (K) Pitch angle of flow at traverse point (degrees);
    (L) Calculated velocity at traverse point both accounting and not accounting for wall effects (ft/sec); and
    (iv) For each RATA using Method 6C, 7E, or 3A in appendix A to part 60 of this chapter to determine SO2, NOX, CO2, or O2 concentration:
    (A) Pollutant or diluent gas being measured;
    (B) Span of reference method analyzer;
    (C) Type of reference method system (e.g., extractive or dilution type);
    (D) Reference method dilution factor (dilution type systems, only);
    (E) Reference gas concentrations (zero, mid, and high gas levels) used for the 3-point pre-test analyzer calibration error test (or, for dilution type reference method systems, for the 3-point pre-test system calibration error test) and for any subsequent recalibrations;
    (F) Analyzer responses to the zero-, mid-, and high-level calibration gases during the 3-point pre-test analyzer (or system) calibration error test and during any subsequent recalibration(s);
    (G) Analyzer calibration error at each gas level (zero, mid, and high) for the 3-point pre-test analyzer (or system) calibration error test and for any subsequent recalibration(s) (percent of span value);
    (H) Upscale gas concentration (mid or high gas level) used for each pre-run or post-run system bias check or (for dilution type reference method systems) for each pre-run or post-run system calibration error check;
    (I) Analyzer response to the calibration gas for each pre-run or post-run system bias (or system calibration error) check;
    (J) The arithmetic average of the analyzer responses to the zero-level gas, for each pair of pre- and post-run system bias (or system calibration error) checks;
    (K) The arithmetic average of the analyzer responses to the upscale calibration gas, for each pair of pre- and post-run system bias (or system calibration error) checks;
    (L) The results of each pre-run and each post-run system bias (or system calibration error) check using the zero-level gas (percentage of span value);
    (M) The results of each pre-run and each post-run system bias (or system calibration error) check using the upscale calibration gas (percentage of span value);
    (N) Calibration drift and zero drift of analyzer during each RATA run (percentage of span value);
    (O) Moisture basis of the reference method analysis;
    (P) Moisture content of stack gas, in percent, during each test run (if needed to convert to moisture basis of CEMS being tested);
    (Q) Unadjusted (raw) average pollutant or diluent gas concentration for each run;
    (R) Average pollutant or diluent gas concentration for each run, corrected for calibration bias (or calibration error) and, if applicable, corrected for moisture;
    (S) The F-factor used to convert reference method data to units of lb/mmBtu (if applicable);
    (T) Date(s) of the latest analyzer interference test(s);
    (U) Results of the latest analyzer interference test(s);
    (V) Date of the latest NO2 to NO conversion test (Method 7E only);
    (W) Results of the latest NO2 to NO conversion test (Method 7E only); and
    (X) For each calibration gas cylinder used during each RATA, record the cylinder gas vendor, cylinder number, expiration date, pollutant(s) in the cylinder, and certified gas concentration(s).
    (v) For each test run of each moisture determination using Method 4 in appendix A to part 60 of this chapter (or its allowable alternatives), whether the determination is made to support a gas RATA, to support a flow RATA, or to quality assure the data from a continuous moisture monitoring system, record the following data elements (as applicable to the moisture measurement method used):
    (A) Test number;
    (B) Run number;
    (C) The beginning date, hour, and minute of the run;
    (D) The ending date, hour, and minute of the run;
    (E) Unit operating level (low, mid, high, or normal, as appropriate);
    (F) Moisture measurement method;
    (G) Volume of H2O collected in the impingers (ml);
    (H) Mass of H2O collected in the silica gel (g);
    (I) Dry gas meter calibration factor;
    (J) Average dry gas meter temperature (°F);
    (K) Barometric pressure (inches of mercury);
    (L) Differential pressure across the orifice meter (inches of H2O);
    (M) Initial and final dry gas meter readings (ft 3);
    (N) Total sample gas volume, corrected to standard conditions (dscf); and
    (vi) The raw data and calculated results for any stratification tests performed in accordance with sections 6.5.6.1 through 6.5.6.3 of appendix A to this part.
    (vii) [Reserved]
    (viii) [Reserved]
    (ix) For a unit with a flow monitor installed on a rectangular stack or duct, if a site-specific default or measured wall effects adjustment factor (WAF) is used to correct the stack gas volumetric flow rate data to account for velocity decay near the stack or duct wall, the owner or operator shall keep records of the following for each flow RATA performed with EPA Method 2 in appendices A-1 and A-2 to part 60 of this chapter, subsequent to the WAF determination:
    (A) Monitoring system ID;
    (B) Test number;
    (C) Operating level;
    (D) RATA end date and time;
    (E) Number of Method 1 traverse points; and
    (F) Wall effects adjustment factor (WAF), to the nearest 0.0001.

Citations to §75.59(a)(7)(iv)(B)

Citations to §75.59(a)(7)(iv)(C)

Citations to §75.59(a)(7)(iv)(D)

Citations to §75.59(a)(7)(iv)(E)

Citations to §75.59(a)(7)(iv)(F)

Citations to §75.59(a)(7)(iv)(G)

Citations to §75.59(a)(7)(iv)(H)

Citations to §75.59(a)(7)(iv)(I)

Citations to §75.59(a)(7)(iv)(J)

Citations to §75.59(a)(7)(iv)(K)

Citations to §75.59(a)(7)(iv)(L)

Citations to §75.59(a)(7)(iv)(M)

Citations to §75.59(a)(7)(iv)(N)

Citations to §75.59(a)(7)(iv)(O)

Citations to §75.59(a)(7)(ix)(A)

Citations to §75.59(a)(7)(ix)(B)

Citations to §75.59(a)(7)(ix)(C)

Citations to §75.59(a)(7)(ix)(D)

Citations to §75.59(a)(7)(ix)(E)

Citations to §75.59(a)(7)(ix)(F)

Citations to §75.59(a)(7)(v)

  • (7) In addition to the information in paragraph (a)(5) of this section, the owner or operator shall record, for each relative accuracy test audit, supporting information sufficient to substantiate compliance with all applicable sections and appendices in this part. Unless otherwise specified in this part or in an applicable test method, the information in paragraphs (a)(7)(i) through (a)(7)(vi) of this section may be recorded either in hard copy format, electronic format or a combination of the two, and the owner or operator shall maintain this information in a format suitable for inspection and audit purposes. This RATA supporting information shall include, but shall not be limited to, the following data elements:
    (i) For each RATA using Reference Method 2 (or its allowable alternatives) in appendix A to part 60 of this chapter to determine volumetric flow rate:
    (A) Information indicating whether or not the location meets requirements of Method 1 in appendix A to part 60 of this chapter; and
    (ii) For each run of each RATA using Reference Method 2 (or its allowable alternatives in appendix A to part 60 of this chapter) to determine volumetric flow rate, record the following data elements (as applicable to the measurement method used):
    (A) Operating level (low, mid, high, or normal, as appropriate);
    (B) Number of reference method traverse points;
    (C) Average stack gas temperature (°F);
    (D) Barometric pressure at test port (inches of mercury);
    (E) Stack static pressure (inches of H2O);
    (F) Absolute stack gas pressure (inches of mercury);
    (G) Percent CO2 and O2 in the stack gas, dry basis;
    (H) CO2 and O2 reference method used;
    (I) Moisture content of stack gas (percent H2O);
    (J) Molecular weight of stack gas, dry basis (lb/lb-mole);
    (K) Molecular weight of stack gas, wet basis (lb/lb-mole);
    (L) Stack diameter (or equivalent diameter) at the test port (ft);
    (M) Average square root of velocity head of stack gas (inches of H2O) for the run;
    (N) Stack or duct cross-sectional area at test port (ft 2);
    (O) Average velocity (ft/sec);
    (P) Average stack flow rate, adjusted, if applicable, for wall effects (scfh, wet basis);
    (Q) Flow rate reference method used;
    (R) Average velocity, adjusted for wall effects;
    (S) Calculated (site-specific) wall effects adjustment factor determined during the run, and, if different, the wall effects adjustment factor used in the calculations; and
    (iii) For each traverse point of each run of each RATA using Reference Method 2 (or its allowable alternatives in appendix A to part 60 of this chapter) to determine volumetric flow rate, record the following data elements (as applicable to the measurement method used):
    (A) Reference method probe type;
    (B) Pressure measurement device type;
    (C) Traverse point ID;
    (D) Probe or pitot tube calibration coefficient;
    (E) Date of latest probe or pitot tube calibration;
    (F) Average velocity differential pressure at traverse point (inches of H2O) or the average of the square roots of the velocity differential pressures at the traverse point ((inches of H2O) 1/2);
    (G) TS, stack temperature at the traverse point (°F);
    (H) Composite (wall effects) traverse point identifier;
    (I) Number of points included in composite traverse point;
    (J) Yaw angle of flow at traverse point (degrees);
    (K) Pitch angle of flow at traverse point (degrees);
    (L) Calculated velocity at traverse point both accounting and not accounting for wall effects (ft/sec); and
    (iv) For each RATA using Method 6C, 7E, or 3A in appendix A to part 60 of this chapter to determine SO2, NOX, CO2, or O2 concentration:
    (A) Pollutant or diluent gas being measured;
    (B) Span of reference method analyzer;
    (C) Type of reference method system (e.g., extractive or dilution type);
    (D) Reference method dilution factor (dilution type systems, only);
    (E) Reference gas concentrations (zero, mid, and high gas levels) used for the 3-point pre-test analyzer calibration error test (or, for dilution type reference method systems, for the 3-point pre-test system calibration error test) and for any subsequent recalibrations;
    (F) Analyzer responses to the zero-, mid-, and high-level calibration gases during the 3-point pre-test analyzer (or system) calibration error test and during any subsequent recalibration(s);
    (G) Analyzer calibration error at each gas level (zero, mid, and high) for the 3-point pre-test analyzer (or system) calibration error test and for any subsequent recalibration(s) (percent of span value);
    (H) Upscale gas concentration (mid or high gas level) used for each pre-run or post-run system bias check or (for dilution type reference method systems) for each pre-run or post-run system calibration error check;
    (I) Analyzer response to the calibration gas for each pre-run or post-run system bias (or system calibration error) check;
    (J) The arithmetic average of the analyzer responses to the zero-level gas, for each pair of pre- and post-run system bias (or system calibration error) checks;
    (K) The arithmetic average of the analyzer responses to the upscale calibration gas, for each pair of pre- and post-run system bias (or system calibration error) checks;
    (L) The results of each pre-run and each post-run system bias (or system calibration error) check using the zero-level gas (percentage of span value);
    (M) The results of each pre-run and each post-run system bias (or system calibration error) check using the upscale calibration gas (percentage of span value);
    (N) Calibration drift and zero drift of analyzer during each RATA run (percentage of span value);
    (O) Moisture basis of the reference method analysis;
    (P) Moisture content of stack gas, in percent, during each test run (if needed to convert to moisture basis of CEMS being tested);
    (Q) Unadjusted (raw) average pollutant or diluent gas concentration for each run;
    (R) Average pollutant or diluent gas concentration for each run, corrected for calibration bias (or calibration error) and, if applicable, corrected for moisture;
    (S) The F-factor used to convert reference method data to units of lb/mmBtu (if applicable);
    (T) Date(s) of the latest analyzer interference test(s);
    (U) Results of the latest analyzer interference test(s);
    (V) Date of the latest NO2 to NO conversion test (Method 7E only);
    (W) Results of the latest NO2 to NO conversion test (Method 7E only); and
    (X) For each calibration gas cylinder used during each RATA, record the cylinder gas vendor, cylinder number, expiration date, pollutant(s) in the cylinder, and certified gas concentration(s).
    (v) For each test run of each moisture determination using Method 4 in appendix A to part 60 of this chapter (or its allowable alternatives), whether the determination is made to support a gas RATA, to support a flow RATA, or to quality assure the data from a continuous moisture monitoring system, record the following data elements (as applicable to the moisture measurement method used):
    (A) Test number;
    (B) Run number;
    (C) The beginning date, hour, and minute of the run;
    (D) The ending date, hour, and minute of the run;
    (E) Unit operating level (low, mid, high, or normal, as appropriate);
    (F) Moisture measurement method;
    (G) Volume of H2O collected in the impingers (ml);
    (H) Mass of H2O collected in the silica gel (g);
    (I) Dry gas meter calibration factor;
    (J) Average dry gas meter temperature (°F);
    (K) Barometric pressure (inches of mercury);
    (L) Differential pressure across the orifice meter (inches of H2O);
    (M) Initial and final dry gas meter readings (ft 3);
    (N) Total sample gas volume, corrected to standard conditions (dscf); and
    (vi) The raw data and calculated results for any stratification tests performed in accordance with sections 6.5.6.1 through 6.5.6.3 of appendix A to this part.
    (vii) [Reserved]
    (viii) [Reserved]
    (ix) For a unit with a flow monitor installed on a rectangular stack or duct, if a site-specific default or measured wall effects adjustment factor (WAF) is used to correct the stack gas volumetric flow rate data to account for velocity decay near the stack or duct wall, the owner or operator shall keep records of the following for each flow RATA performed with EPA Method 2 in appendices A-1 and A-2 to part 60 of this chapter, subsequent to the WAF determination:
    (A) Monitoring system ID;
    (B) Test number;
    (C) Operating level;
    (D) RATA end date and time;
    (E) Number of Method 1 traverse points; and
    (F) Wall effects adjustment factor (WAF), to the nearest 0.0001.
  • (xii) Supplementary RATA information required under § 75.59(a)(7)(i) through § 75.59(a)(7)(v), except that:
    (A) The applicable data elements under § 75.59(a)(7)(ii)(A) through (T) and under § 75.59(a)(7)(iii)(A) through (M) shall be reported for flow RATAs at circular or rectangular stacks (or ducts) in which angular compensation for yaw and/or pitch angles is used (i.e., Method 2F or 2G in appendices A-1 and A-2 to part 60 of this chapter), with or without wall effects adjustments;
    (B) The applicable data elements under § 75.59(a)(7)(ii)(A) through (T) and under § 75.59(a)(7)(iii)(A) through (M) shall be reported for any flow RATA run at a circular stack in which Method 2 in appendices A-1 and A-2 to part 60 of this chapter is used and a wall effects adjustment factor is determined by direct measurement;
    (C) The data under § 75.59(a)(7)(ii)(T) shall be reported for all flow RATAs at circular stacks in which Method 2 in appendices A-1 and A-2 to part 60 of this chapter is used and a default wall effects adjustment factor is applied; and
    (D) The data under § 75.59(a)(7)(ix)(A) through (F) shall be reported for all flow RATAs at rectangular stacks or ducts in which Method 2 in appendices A-1 and A-2 to part 60 of this chapter is used and a wall effects adjustment factor is applied; and

Citations to §75.59(a)(7)(v)(A)

Citations to §75.59(a)(7)(v)(B)

Citations to §75.59(a)(7)(v)(C)

Citations to §75.59(a)(7)(v)(D)

Citations to §75.59(a)(7)(v)(E)

Citations to §75.59(a)(7)(v)(F)

Citations to §75.59(a)(7)(v)(G)

Citations to §75.59(a)(7)(v)(H)

Citations to §75.59(a)(7)(v)(I)

Citations to §75.59(a)(7)(v)(J)

Citations to §75.59(a)(7)(v)(K)

Citations to §75.59(a)(7)(v)(L)

Citations to §75.59(a)(7)(v)(M)

Citations to §75.59(a)(7)(v)(N)

Citations to §75.59(a)(7)(v)(O)

Citations to §75.59(a)(7)(vi)

  • (7) In addition to the information in paragraph (a)(5) of this section, the owner or operator shall record, for each relative accuracy test audit, supporting information sufficient to substantiate compliance with all applicable sections and appendices in this part. Unless otherwise specified in this part or in an applicable test method, the information in paragraphs (a)(7)(i) through (a)(7)(vi) of this section may be recorded either in hard copy format, electronic format or a combination of the two, and the owner or operator shall maintain this information in a format suitable for inspection and audit purposes. This RATA supporting information shall include, but shall not be limited to, the following data elements:
    (i) For each RATA using Reference Method 2 (or its allowable alternatives) in appendix A to part 60 of this chapter to determine volumetric flow rate:
    (A) Information indicating whether or not the location meets requirements of Method 1 in appendix A to part 60 of this chapter; and
    (ii) For each run of each RATA using Reference Method 2 (or its allowable alternatives in appendix A to part 60 of this chapter) to determine volumetric flow rate, record the following data elements (as applicable to the measurement method used):
    (A) Operating level (low, mid, high, or normal, as appropriate);
    (B) Number of reference method traverse points;
    (C) Average stack gas temperature (°F);
    (D) Barometric pressure at test port (inches of mercury);
    (E) Stack static pressure (inches of H2O);
    (F) Absolute stack gas pressure (inches of mercury);
    (G) Percent CO2 and O2 in the stack gas, dry basis;
    (H) CO2 and O2 reference method used;
    (I) Moisture content of stack gas (percent H2O);
    (J) Molecular weight of stack gas, dry basis (lb/lb-mole);
    (K) Molecular weight of stack gas, wet basis (lb/lb-mole);
    (L) Stack diameter (or equivalent diameter) at the test port (ft);
    (M) Average square root of velocity head of stack gas (inches of H2O) for the run;
    (N) Stack or duct cross-sectional area at test port (ft 2);
    (O) Average velocity (ft/sec);
    (P) Average stack flow rate, adjusted, if applicable, for wall effects (scfh, wet basis);
    (Q) Flow rate reference method used;
    (R) Average velocity, adjusted for wall effects;
    (S) Calculated (site-specific) wall effects adjustment factor determined during the run, and, if different, the wall effects adjustment factor used in the calculations; and
    (iii) For each traverse point of each run of each RATA using Reference Method 2 (or its allowable alternatives in appendix A to part 60 of this chapter) to determine volumetric flow rate, record the following data elements (as applicable to the measurement method used):
    (A) Reference method probe type;
    (B) Pressure measurement device type;
    (C) Traverse point ID;
    (D) Probe or pitot tube calibration coefficient;
    (E) Date of latest probe or pitot tube calibration;
    (F) Average velocity differential pressure at traverse point (inches of H2O) or the average of the square roots of the velocity differential pressures at the traverse point ((inches of H2O) 1/2);
    (G) TS, stack temperature at the traverse point (°F);
    (H) Composite (wall effects) traverse point identifier;
    (I) Number of points included in composite traverse point;
    (J) Yaw angle of flow at traverse point (degrees);
    (K) Pitch angle of flow at traverse point (degrees);
    (L) Calculated velocity at traverse point both accounting and not accounting for wall effects (ft/sec); and
    (iv) For each RATA using Method 6C, 7E, or 3A in appendix A to part 60 of this chapter to determine SO2, NOX, CO2, or O2 concentration:
    (A) Pollutant or diluent gas being measured;
    (B) Span of reference method analyzer;
    (C) Type of reference method system (e.g., extractive or dilution type);
    (D) Reference method dilution factor (dilution type systems, only);
    (E) Reference gas concentrations (zero, mid, and high gas levels) used for the 3-point pre-test analyzer calibration error test (or, for dilution type reference method systems, for the 3-point pre-test system calibration error test) and for any subsequent recalibrations;
    (F) Analyzer responses to the zero-, mid-, and high-level calibration gases during the 3-point pre-test analyzer (or system) calibration error test and during any subsequent recalibration(s);
    (G) Analyzer calibration error at each gas level (zero, mid, and high) for the 3-point pre-test analyzer (or system) calibration error test and for any subsequent recalibration(s) (percent of span value);
    (H) Upscale gas concentration (mid or high gas level) used for each pre-run or post-run system bias check or (for dilution type reference method systems) for each pre-run or post-run system calibration error check;
    (I) Analyzer response to the calibration gas for each pre-run or post-run system bias (or system calibration error) check;
    (J) The arithmetic average of the analyzer responses to the zero-level gas, for each pair of pre- and post-run system bias (or system calibration error) checks;
    (K) The arithmetic average of the analyzer responses to the upscale calibration gas, for each pair of pre- and post-run system bias (or system calibration error) checks;
    (L) The results of each pre-run and each post-run system bias (or system calibration error) check using the zero-level gas (percentage of span value);
    (M) The results of each pre-run and each post-run system bias (or system calibration error) check using the upscale calibration gas (percentage of span value);
    (N) Calibration drift and zero drift of analyzer during each RATA run (percentage of span value);
    (O) Moisture basis of the reference method analysis;
    (P) Moisture content of stack gas, in percent, during each test run (if needed to convert to moisture basis of CEMS being tested);
    (Q) Unadjusted (raw) average pollutant or diluent gas concentration for each run;
    (R) Average pollutant or diluent gas concentration for each run, corrected for calibration bias (or calibration error) and, if applicable, corrected for moisture;
    (S) The F-factor used to convert reference method data to units of lb/mmBtu (if applicable);
    (T) Date(s) of the latest analyzer interference test(s);
    (U) Results of the latest analyzer interference test(s);
    (V) Date of the latest NO2 to NO conversion test (Method 7E only);
    (W) Results of the latest NO2 to NO conversion test (Method 7E only); and
    (X) For each calibration gas cylinder used during each RATA, record the cylinder gas vendor, cylinder number, expiration date, pollutant(s) in the cylinder, and certified gas concentration(s).
    (v) For each test run of each moisture determination using Method 4 in appendix A to part 60 of this chapter (or its allowable alternatives), whether the determination is made to support a gas RATA, to support a flow RATA, or to quality assure the data from a continuous moisture monitoring system, record the following data elements (as applicable to the moisture measurement method used):
    (A) Test number;
    (B) Run number;
    (C) The beginning date, hour, and minute of the run;
    (D) The ending date, hour, and minute of the run;
    (E) Unit operating level (low, mid, high, or normal, as appropriate);
    (F) Moisture measurement method;
    (G) Volume of H2O collected in the impingers (ml);
    (H) Mass of H2O collected in the silica gel (g);
    (I) Dry gas meter calibration factor;
    (J) Average dry gas meter temperature (°F);
    (K) Barometric pressure (inches of mercury);
    (L) Differential pressure across the orifice meter (inches of H2O);
    (M) Initial and final dry gas meter readings (ft 3);
    (N) Total sample gas volume, corrected to standard conditions (dscf); and
    (vi) The raw data and calculated results for any stratification tests performed in accordance with sections 6.5.6.1 through 6.5.6.3 of appendix A to this part.
    (vii) [Reserved]
    (viii) [Reserved]
    (ix) For a unit with a flow monitor installed on a rectangular stack or duct, if a site-specific default or measured wall effects adjustment factor (WAF) is used to correct the stack gas volumetric flow rate data to account for velocity decay near the stack or duct wall, the owner or operator shall keep records of the following for each flow RATA performed with EPA Method 2 in appendices A-1 and A-2 to part 60 of this chapter, subsequent to the WAF determination:
    (A) Monitoring system ID;
    (B) Test number;
    (C) Operating level;
    (D) RATA end date and time;
    (E) Number of Method 1 traverse points; and
    (F) Wall effects adjustment factor (WAF), to the nearest 0.0001.

Citations to §75.59(a)(8)

Citations to §75.59(a)(9)

  • (6) If requested in writing (or by electronic mail) by the applicable EPA Regional Office, appropriate State, and/or appropriate local air pollution control agency, the designated representative shall submit a hardcopy RATA report within 45 days after completing a required semiannual or annual RATA according to section 2.3.1 of appendix B to this part, or within 15 days of receiving the request, whichever is later. The designated representative shall report the hardcopy information required by § 75.59(a)(9) to the applicable EPA Regional Office, appropriate State, and/or appropriate local air pollution control agency that requested the RATA report.
  • (ii) The results of the test(s) required by § 75.20, including the type of test conducted, testing date, information required by § 75.59(a)(9), and the results of any failed tests that affect data validation.
  • (4) If requested by the permitting authority, the designated representative of an affected unit shall submit the quality assurance RATA report for each affected unit or group of units monitored at a common stack and each non-affected unit under § 75.72(b)(2)(ii) by the later of 45 days after completing a quality assurance RATA according to section 2.3 of appendix B to this part or 15 days of receiving the request. The designated representative shall report the hardcopy information required by § 75.59(a)(9) to the permitting authority.

Citations to §75.59(a)(9)(x)

  • (5) The daily calibration error test and daily interference check information required in § 75.59(a)(1) and (a)(2) must always be included in the electronic quarterly emissions report. All other certification, quality assurance, and quality control information in § 75.59 that is not excluded from electronic reporting under paragraph (a)(2) or (a)(7) of this section shall be submitted separately, either prior to or concurrent with the submittal of the relevant electronic quarterly emissions report. However, reporting of the information in § 75.59(a)(9)(x) is not required until September 26, 2011, and reporting of the information in § 75.59(a)(15), (b)(6), and (d)(4) is not required until March 27, 2012.

Citations to §75.59(a)(9)(x)(A)(1)

Citations to §75.59(a)(15)

  • (5) The daily calibration error test and daily interference check information required in § 75.59(a)(1) and (a)(2) must always be included in the electronic quarterly emissions report. All other certification, quality assurance, and quality control information in § 75.59 that is not excluded from electronic reporting under paragraph (a)(2) or (a)(7) of this section shall be submitted separately, either prior to or concurrent with the submittal of the relevant electronic quarterly emissions report. However, reporting of the information in § 75.59(a)(9)(x) is not required until September 26, 2011, and reporting of the information in § 75.59(a)(15), (b)(6), and (d)(4) is not required until March 27, 2012.

Citations to §75.59(b)(1)(ix)

Citations to §75.59(b)(1)(vi)

Citations to §75.59(b)(1)(vii)

Citations to §75.59(b)(1)(viii)

Citations to §75.59(b)(1)(xiii)

Citations to §75.59(b)(2)

Citations to §75.59(b)(2)(iii)

Citations to §75.59(b)(2)(iv)

Citations to §75.59(b)(5)

  • (7) If requested in writing (or by electronic mail) by the applicable EPA Regional Office, appropriate State, and/or appropriate local air pollution control agency, the designated representative shall submit a hardcopy report within 45 days after completing a required periodic retest according to section 2.2 of appendix E to this part, or within 15 days of receiving the request, whichever is later. The designated representative shall report the hardcopy information required by § 75.59(b)(5) to the applicable EPA Regional Office, appropriate State, and/or appropriate local air pollution control agency that requested the hardcopy report.
  • (6) If requested by the applicable EPA Regional Office, appropriate State, and/or appropriate local air pollution control agency, the designated representative shall submit a hardcopy report within 45 days after completing a required periodic retest according to section 2.2 of appendix E to this part, or within 15 days of receiving the request, whichever is later. The designated representative shall report the hardcopy information required by § 75.59(b)(5) to the applicable EPA Regional Office, appropriate State, and/or appropriate local air pollution control agency that requested the hardcopy report.

Citations to §75.59(b)(6)

  • (5) The daily calibration error test and daily interference check information required in § 75.59(a)(1) and (a)(2) must always be included in the electronic quarterly emissions report. All other certification, quality assurance, and quality control information in § 75.59 that is not excluded from electronic reporting under paragraph (a)(2) or (a)(7) of this section shall be submitted separately, either prior to or concurrent with the submittal of the relevant electronic quarterly emissions report. However, reporting of the information in § 75.59(a)(9)(x) is not required until September 26, 2011, and reporting of the information in § 75.59(a)(15), (b)(6), and (d)(4) is not required until March 27, 2012.

Citations to §75.59(d)(4)

  • (5) The daily calibration error test and daily interference check information required in § 75.59(a)(1) and (a)(2) must always be included in the electronic quarterly emissions report. All other certification, quality assurance, and quality control information in § 75.59 that is not excluded from electronic reporting under paragraph (a)(2) or (a)(7) of this section shall be submitted separately, either prior to or concurrent with the submittal of the relevant electronic quarterly emissions report. However, reporting of the information in § 75.59(a)(9)(x) is not required until September 26, 2011, and reporting of the information in § 75.59(a)(15), (b)(6), and (d)(4) is not required until March 27, 2012.

Citations to §75.59(e)