§63.7296. What emission limitations must I meet for battery stacks? — Inbound Citations
40 C.F.R. § 63.7296
Statutory Authority
Cited by 28 regulations in release Current.
Citations to 40 U.S.C. § 63.7296 as a whole
-
(b) For each new or existing by-product coke oven battery subject to the emission limits in § 63.7296, you have demonstrated initial compliance if you meet the requirements in paragraphs (b)(1) through (5) of this section.(1) The opacity limit for stacks in § 63.7296(a), you have demonstrated initial compliance if the daily average opacity, as measured according to the performance test procedures in § 63.7324(b), is no more than 15 percent for a battery on a normal coking cycle or 20 percent for a battery on batterywide extended coking.(2) The concentration of particulate matter, measured in accordance with the performance test procedures in § 63.7322(b)(1) and (2), did not exceed 0.013 gr/dscf at 10 percent oxygen from a battery stack at a new by-product coke oven battery or 0.13 gr/dscf at 10 percent oxygen from a battery stack at an existing by-product coke oven battery.(3) The process-weighted mass rate of mercury (lb/ton of coke), measured in accordance with the performance test procedures in § 63.7322(c)(1) through (4), did not exceed 7.1E-06 lb/ton coke from a battery stack at a new by-product coke oven battery or 4.5E-05 lb/ton coke from a battery stack at an existing by-product coke oven battery.(4) The process-weighted mass rate of total acid gases (lb/ton of coke), measured in accordance with the performance test procedures in § 63.7322(d)(1) through (4), did not exceed 0.013 lb/ton coke from a battery stack at a new by-product coke oven battery or 0.16 lb/ton coke from a battery stack at an existing by-product coke oven battery.(5) The process-weighted mass rate of hydrogen cyanide (lb/ton of coke), measured in accordance with the performance test procedures in § 63.7322(e)(1) through (4), did not exceed 7.4E-04 lb/ton coke from a battery stack at a new by-product coke oven battery or 0.032 lb/ton coke from a battery stack at an existing by-product coke oven battery.
-
(b) Each quarterly report must provide information on compliance with the emission limitations for battery stacks in § 63.7296. The reports must include the information in paragraphs (c)(1) through (3), and as applicable, paragraphs (c)(4) through (8) of this section.
Citations to §63.7296(a)
-
(1) The opacity limit for stacks in § 63.7296(a), you have demonstrated initial compliance if the daily average opacity, as measured according to the performance test procedures in § 63.7324(b), is no more than 15 percent for a battery on a normal coking cycle or 20 percent for a battery on batterywide extended coking.
-
(f) Beginning on the first day compliance is required under § 63.7283, you must demonstrate continuous compliance for each by-product coke oven battery subject to the opacity limit for battery stacks in § 63.7296(a) by meeting the requirements in paragraphs (f)(1) and (2) of this section:(1) Maintaining the daily average opacity at or below 15 percent for a battery on a normal coking cycle or 20 percent for a battery on batterywide extended coking; and(2) Operating and maintaining a COMS and collecting and reducing the COMS data according to § 63.7331(j).
Citations to §63.7296(c)
-
(d) An affected source at your coke plant is new if you commenced construction or reconstruction of the affected source on or after July 3, 2001. An affected source is reconstructed if it meets the definition of “reconstruction” in § 63.2. This paragraph (d) does not apply to the emission limitations listed in §§ 63.7290(b) through (d), 63.7296(c) through (f), 63.7297(a) through (d), and 63.7298(a) through (e) for capture systems and control devices applied to pushing emissions, battery stacks, HNR HRSG main stacks, and HNR HRSG bypass/waste heat stacks, respectively.
-
(a) If you have an existing affected source, you must comply with each emission limitation, work practice standard, and operation and maintenance requirement in this subpart that applies to you no later than April 14, 2006. This paragraph does not apply to the emission limitations listed in §§ 63.7290(b) through (d), 63.7296(c) through (f), 63.7297(a) through (d), and 63.7298(a) through (e) for capture systems and control devices applied to pushing emissions, battery stacks, HNR HRSG main stacks, and HNR HRSG bypass/waste heat stacks, respectively.
-
You must not discharge to the atmosphere any emissions from any battery stack at a new or existing by-product coke oven battery that exhibit an opacity greater than the applicable limits in paragraphs (a) and (b) of this section and emissions greater than the applicable limits in paragraphs (c) through (f) of this section.
-
(2) Section 63.7296(c) through (f) for emissions of particulate matter, mercury, total acid gases, and HCN from a battery stack that applies to you within 180 calendar days after the compliance date that is specified in § 63.7283.
-
(b) For each source subject to emission limits in §§ 63.7290(b) through (d), 63.7296(c) through (f), 63.7297(a) through (d), and 63.7298(a) through (e) for capture systems and control devices applied to pushing emissions, battery stacks, HNR HRSG main stacks, and HNR HRSG bypass/waste heat stacks sources, respectively, you must conduct subsequent performance tests once every five years.
-
(g) For each battery stack subject to the emission limits in § 63.7296(c) through (f), you must demonstrate continuous compliance by meeting the requirements in paragraphs (g)(1) through (5) of this section:(1) Maintaining emissions of particulate matter at or below the applicable limits in § 63.7296(c);(2) Maintaining emissions of mercury at or below the applicable limits in § 63.7296(d);(3) Maintaining emissions of total acid gases at or below the applicable limits in § 63.7296(e);(4) Maintaining emissions of hydrogen cyanide at or below the applicable limits in § 63.7296(f); and
Citations to §63.7296(d)
-
(d) An affected source at your coke plant is new if you commenced construction or reconstruction of the affected source on or after July 3, 2001. An affected source is reconstructed if it meets the definition of “reconstruction” in § 63.2. This paragraph (d) does not apply to the emission limitations listed in §§ 63.7290(b) through (d), 63.7296(c) through (f), 63.7297(a) through (d), and 63.7298(a) through (e) for capture systems and control devices applied to pushing emissions, battery stacks, HNR HRSG main stacks, and HNR HRSG bypass/waste heat stacks, respectively.
-
(a) If you have an existing affected source, you must comply with each emission limitation, work practice standard, and operation and maintenance requirement in this subpart that applies to you no later than April 14, 2006. This paragraph does not apply to the emission limitations listed in §§ 63.7290(b) through (d), 63.7296(c) through (f), 63.7297(a) through (d), and 63.7298(a) through (e) for capture systems and control devices applied to pushing emissions, battery stacks, HNR HRSG main stacks, and HNR HRSG bypass/waste heat stacks, respectively.
-
You must not discharge to the atmosphere any emissions from any battery stack at a new or existing by-product coke oven battery that exhibit an opacity greater than the applicable limits in paragraphs (a) and (b) of this section and emissions greater than the applicable limits in paragraphs (c) through (f) of this section.
-
(2) Section 63.7296(c) through (f) for emissions of particulate matter, mercury, total acid gases, and HCN from a battery stack that applies to you within 180 calendar days after the compliance date that is specified in § 63.7283.
-
(b) For each source subject to emission limits in §§ 63.7290(b) through (d), 63.7296(c) through (f), 63.7297(a) through (d), and 63.7298(a) through (e) for capture systems and control devices applied to pushing emissions, battery stacks, HNR HRSG main stacks, and HNR HRSG bypass/waste heat stacks sources, respectively, you must conduct subsequent performance tests once every five years.
-
(g) For each battery stack subject to the emission limits in § 63.7296(c) through (f), you must demonstrate continuous compliance by meeting the requirements in paragraphs (g)(1) through (5) of this section:(1) Maintaining emissions of particulate matter at or below the applicable limits in § 63.7296(c);(2) Maintaining emissions of mercury at or below the applicable limits in § 63.7296(d);(3) Maintaining emissions of total acid gases at or below the applicable limits in § 63.7296(e);(4) Maintaining emissions of hydrogen cyanide at or below the applicable limits in § 63.7296(f); and
Citations to §63.7296(e)
-
(d) An affected source at your coke plant is new if you commenced construction or reconstruction of the affected source on or after July 3, 2001. An affected source is reconstructed if it meets the definition of “reconstruction” in § 63.2. This paragraph (d) does not apply to the emission limitations listed in §§ 63.7290(b) through (d), 63.7296(c) through (f), 63.7297(a) through (d), and 63.7298(a) through (e) for capture systems and control devices applied to pushing emissions, battery stacks, HNR HRSG main stacks, and HNR HRSG bypass/waste heat stacks, respectively.
-
(a) If you have an existing affected source, you must comply with each emission limitation, work practice standard, and operation and maintenance requirement in this subpart that applies to you no later than April 14, 2006. This paragraph does not apply to the emission limitations listed in §§ 63.7290(b) through (d), 63.7296(c) through (f), 63.7297(a) through (d), and 63.7298(a) through (e) for capture systems and control devices applied to pushing emissions, battery stacks, HNR HRSG main stacks, and HNR HRSG bypass/waste heat stacks, respectively.
-
You must not discharge to the atmosphere any emissions from any battery stack at a new or existing by-product coke oven battery that exhibit an opacity greater than the applicable limits in paragraphs (a) and (b) of this section and emissions greater than the applicable limits in paragraphs (c) through (f) of this section.
-
(2) Section 63.7296(c) through (f) for emissions of particulate matter, mercury, total acid gases, and HCN from a battery stack that applies to you within 180 calendar days after the compliance date that is specified in § 63.7283.
-
(b) For each source subject to emission limits in §§ 63.7290(b) through (d), 63.7296(c) through (f), 63.7297(a) through (d), and 63.7298(a) through (e) for capture systems and control devices applied to pushing emissions, battery stacks, HNR HRSG main stacks, and HNR HRSG bypass/waste heat stacks sources, respectively, you must conduct subsequent performance tests once every five years.
-
(g) For each battery stack subject to the emission limits in § 63.7296(c) through (f), you must demonstrate continuous compliance by meeting the requirements in paragraphs (g)(1) through (5) of this section:(1) Maintaining emissions of particulate matter at or below the applicable limits in § 63.7296(c);(2) Maintaining emissions of mercury at or below the applicable limits in § 63.7296(d);(3) Maintaining emissions of total acid gases at or below the applicable limits in § 63.7296(e);(4) Maintaining emissions of hydrogen cyanide at or below the applicable limits in § 63.7296(f); and
Citations to §63.7296(f)
-
(d) An affected source at your coke plant is new if you commenced construction or reconstruction of the affected source on or after July 3, 2001. An affected source is reconstructed if it meets the definition of “reconstruction” in § 63.2. This paragraph (d) does not apply to the emission limitations listed in §§ 63.7290(b) through (d), 63.7296(c) through (f), 63.7297(a) through (d), and 63.7298(a) through (e) for capture systems and control devices applied to pushing emissions, battery stacks, HNR HRSG main stacks, and HNR HRSG bypass/waste heat stacks, respectively.
-
(a) If you have an existing affected source, you must comply with each emission limitation, work practice standard, and operation and maintenance requirement in this subpart that applies to you no later than April 14, 2006. This paragraph does not apply to the emission limitations listed in §§ 63.7290(b) through (d), 63.7296(c) through (f), 63.7297(a) through (d), and 63.7298(a) through (e) for capture systems and control devices applied to pushing emissions, battery stacks, HNR HRSG main stacks, and HNR HRSG bypass/waste heat stacks, respectively.
-
You must not discharge to the atmosphere any emissions from any battery stack at a new or existing by-product coke oven battery that exhibit an opacity greater than the applicable limits in paragraphs (a) and (b) of this section and emissions greater than the applicable limits in paragraphs (c) through (f) of this section.
-
(2) Section 63.7296(c) through (f) for emissions of particulate matter, mercury, total acid gases, and HCN from a battery stack that applies to you within 180 calendar days after the compliance date that is specified in § 63.7283.
-
(b) For each source subject to emission limits in §§ 63.7290(b) through (d), 63.7296(c) through (f), 63.7297(a) through (d), and 63.7298(a) through (e) for capture systems and control devices applied to pushing emissions, battery stacks, HNR HRSG main stacks, and HNR HRSG bypass/waste heat stacks sources, respectively, you must conduct subsequent performance tests once every five years.
-
(g) For each battery stack subject to the emission limits in § 63.7296(c) through (f), you must demonstrate continuous compliance by meeting the requirements in paragraphs (g)(1) through (5) of this section:(1) Maintaining emissions of particulate matter at or below the applicable limits in § 63.7296(c);(2) Maintaining emissions of mercury at or below the applicable limits in § 63.7296(d);(3) Maintaining emissions of total acid gases at or below the applicable limits in § 63.7296(e);(4) Maintaining emissions of hydrogen cyanide at or below the applicable limits in § 63.7296(f); and