§63.7290. What emission limitations must I meet for capture systems and control devices applied to pushing emissions? — Inbound Citations
40 C.F.R. § 63.7290
Statutory Authority
Cited by 50 regulations in release Current.
Citations to 40 U.S.C. § 63.7290 as a whole
-
(2) Three valid test runs are needed to comprise a performance test. During each particulate matter test run to meet the emission limitations in § 63.7290, sample only during periods of actual pushing when the capture system fan and control device are engaged. For capture systems and control devices applied to pushing emissions each run must start at the beginning of a push and finish at the end of a push (i.e., sample for an integral number of pushes).
Citations to §63.7290(a)
-
(1) Section 63.7290(a) through (e) for emissions of particulate matter, mercury, total acid gases, HCN, and total PAH from a control device applied to pushing emissions that applies to you within 180 calendar days after the compliance date that is specified in § 63.7283.
-
(a) For each control device subject to an emission limit for particulate matter in § 63.7290(a), you must conduct subsequent performance tests no less frequently than once every 5 years or at the beginning of each term of your title V operating permit, whichever is less.
-
(2) Conduct a performance test to demonstrate that emissions of particulate matter from the control device do not exceed the applicable limit in § 63.7290(a).
-
(a) For each control device applied to pushing emissions and subject to the emission limit in § 63.7290(a), you must demonstrate continuous compliance by meeting the requirements in paragraphs (a)(1) and (2) of this section:(1) Maintaining emissions of particulate matter at or below the applicable limits in paragraphs § 63.7290(a)(1) through (4); and(2) Conducting subsequent performance tests to demonstrate continuous compliance no less frequently than at the beginning of your title V operating permit or every 5 years, whichever is less.
Citations to §63.7290(a)(1)
-
(a) You must not discharge to the atmosphere emissions of particulate matter from a control device applied to pushing emissions from a new or existing coke oven battery that exceed the applicable limit in paragraphs (a)(1) through (4) of this section:(1) 0.01 grain per dry standard cubic foot (gr/dscf) if a cokeside shed is used to capture emissions;(2) 0.02 pound per ton (lb/ton) of coke if a moveable hood vented to a stationary control device is used to capture emissions;(3) If a mobile scrubber car that does not capture emissions during travel is used:(i) 0.03 lb/ton of coke for a control device applied to pushing emissions from a short battery, or(ii) 0.01 lb/ton of coke for a control device applied to pushing emissions from a tall battery; and(4) 0.04 lb/ton of coke if a mobile control device that captures emissions during travel is used.
-
(1) Maintaining emissions of particulate matter at or below the applicable limits in paragraphs § 63.7290(a)(1) through (4); and
Citations to §63.7290(a)(2)
-
(a) You must not discharge to the atmosphere emissions of particulate matter from a control device applied to pushing emissions from a new or existing coke oven battery that exceed the applicable limit in paragraphs (a)(1) through (4) of this section:(1) 0.01 grain per dry standard cubic foot (gr/dscf) if a cokeside shed is used to capture emissions;(2) 0.02 pound per ton (lb/ton) of coke if a moveable hood vented to a stationary control device is used to capture emissions;(3) If a mobile scrubber car that does not capture emissions during travel is used:(i) 0.03 lb/ton of coke for a control device applied to pushing emissions from a short battery, or(ii) 0.01 lb/ton of coke for a control device applied to pushing emissions from a tall battery; and(4) 0.04 lb/ton of coke if a mobile control device that captures emissions during travel is used.
-
(1) Maintaining emissions of particulate matter at or below the applicable limits in paragraphs § 63.7290(a)(1) through (4); and
Citations to §63.7290(a)(3)
-
(a) You must not discharge to the atmosphere emissions of particulate matter from a control device applied to pushing emissions from a new or existing coke oven battery that exceed the applicable limit in paragraphs (a)(1) through (4) of this section:(1) 0.01 grain per dry standard cubic foot (gr/dscf) if a cokeside shed is used to capture emissions;(2) 0.02 pound per ton (lb/ton) of coke if a moveable hood vented to a stationary control device is used to capture emissions;(3) If a mobile scrubber car that does not capture emissions during travel is used:(i) 0.03 lb/ton of coke for a control device applied to pushing emissions from a short battery, or(ii) 0.01 lb/ton of coke for a control device applied to pushing emissions from a tall battery; and(4) 0.04 lb/ton of coke if a mobile control device that captures emissions during travel is used.
-
(1) Maintaining emissions of particulate matter at or below the applicable limits in paragraphs § 63.7290(a)(1) through (4); and
Citations to §63.7290(a)(4)
-
(a) You must not discharge to the atmosphere emissions of particulate matter from a control device applied to pushing emissions from a new or existing coke oven battery that exceed the applicable limit in paragraphs (a)(1) through (4) of this section:(1) 0.01 grain per dry standard cubic foot (gr/dscf) if a cokeside shed is used to capture emissions;(2) 0.02 pound per ton (lb/ton) of coke if a moveable hood vented to a stationary control device is used to capture emissions;(3) If a mobile scrubber car that does not capture emissions during travel is used:(i) 0.03 lb/ton of coke for a control device applied to pushing emissions from a short battery, or(ii) 0.01 lb/ton of coke for a control device applied to pushing emissions from a tall battery; and(4) 0.04 lb/ton of coke if a mobile control device that captures emissions during travel is used.
-
(1) Maintaining emissions of particulate matter at or below the applicable limits in paragraphs § 63.7290(a)(1) through (4); and
Citations to §63.7290(b)
-
(d) An affected source at your coke plant is new if you commenced construction or reconstruction of the affected source on or after July 3, 2001. An affected source is reconstructed if it meets the definition of “reconstruction” in § 63.2. This paragraph (d) does not apply to the emission limitations listed in §§ 63.7290(b) through (d), 63.7296(c) through (f), 63.7297(a) through (d), and 63.7298(a) through (e) for capture systems and control devices applied to pushing emissions, battery stacks, HNR HRSG main stacks, and HNR HRSG bypass/waste heat stacks, respectively.
-
(a) If you have an existing affected source, you must comply with each emission limitation, work practice standard, and operation and maintenance requirement in this subpart that applies to you no later than April 14, 2006. This paragraph does not apply to the emission limitations listed in §§ 63.7290(b) through (d), 63.7296(c) through (f), 63.7297(a) through (d), and 63.7298(a) through (e) for capture systems and control devices applied to pushing emissions, battery stacks, HNR HRSG main stacks, and HNR HRSG bypass/waste heat stacks, respectively.
-
(1) Section 63.7290(a) through (e) for emissions of particulate matter, mercury, total acid gases, HCN, and total PAH from a control device applied to pushing emissions that applies to you within 180 calendar days after the compliance date that is specified in § 63.7283.
-
(b) For each source subject to emission limits in §§ 63.7290(b) through (d), 63.7296(c) through (f), 63.7297(a) through (d), and 63.7298(a) through (e) for capture systems and control devices applied to pushing emissions, battery stacks, HNR HRSG main stacks, and HNR HRSG bypass/waste heat stacks sources, respectively, you must conduct subsequent performance tests once every five years.
-
(b) For each control device applied to pushing emissions and subject to the emission limits in § 63.7290(b) through (e), you must demonstrate continuous compliance by meeting the requirements in paragraphs (b)(1) through (5) of this section:(1) Maintaining emissions of mercury at or below the applicable limits in § 63.7290(b);(2) Maintaining emissions of total acid gases at or below the applicable limits in § 63.7290(c);(3) Maintaining emissions of hydrogen cyanide at or below the applicable limits in § 63.7290(d);(4) Maintaining emissions of total PAHs at or below the applicable limits in § 63.7290(e); and
Citations to §63.7290(c)
-
(d) An affected source at your coke plant is new if you commenced construction or reconstruction of the affected source on or after July 3, 2001. An affected source is reconstructed if it meets the definition of “reconstruction” in § 63.2. This paragraph (d) does not apply to the emission limitations listed in §§ 63.7290(b) through (d), 63.7296(c) through (f), 63.7297(a) through (d), and 63.7298(a) through (e) for capture systems and control devices applied to pushing emissions, battery stacks, HNR HRSG main stacks, and HNR HRSG bypass/waste heat stacks, respectively.
-
(a) If you have an existing affected source, you must comply with each emission limitation, work practice standard, and operation and maintenance requirement in this subpart that applies to you no later than April 14, 2006. This paragraph does not apply to the emission limitations listed in §§ 63.7290(b) through (d), 63.7296(c) through (f), 63.7297(a) through (d), and 63.7298(a) through (e) for capture systems and control devices applied to pushing emissions, battery stacks, HNR HRSG main stacks, and HNR HRSG bypass/waste heat stacks, respectively.
-
(1) Section 63.7290(a) through (e) for emissions of particulate matter, mercury, total acid gases, HCN, and total PAH from a control device applied to pushing emissions that applies to you within 180 calendar days after the compliance date that is specified in § 63.7283.
-
(b) For each source subject to emission limits in §§ 63.7290(b) through (d), 63.7296(c) through (f), 63.7297(a) through (d), and 63.7298(a) through (e) for capture systems and control devices applied to pushing emissions, battery stacks, HNR HRSG main stacks, and HNR HRSG bypass/waste heat stacks sources, respectively, you must conduct subsequent performance tests once every five years.
-
(b) For each control device applied to pushing emissions and subject to the emission limits in § 63.7290(b) through (e), you must demonstrate continuous compliance by meeting the requirements in paragraphs (b)(1) through (5) of this section:(1) Maintaining emissions of mercury at or below the applicable limits in § 63.7290(b);(2) Maintaining emissions of total acid gases at or below the applicable limits in § 63.7290(c);(3) Maintaining emissions of hydrogen cyanide at or below the applicable limits in § 63.7290(d);(4) Maintaining emissions of total PAHs at or below the applicable limits in § 63.7290(e); and
Citations to §63.7290(d)
-
(d) An affected source at your coke plant is new if you commenced construction or reconstruction of the affected source on or after July 3, 2001. An affected source is reconstructed if it meets the definition of “reconstruction” in § 63.2. This paragraph (d) does not apply to the emission limitations listed in §§ 63.7290(b) through (d), 63.7296(c) through (f), 63.7297(a) through (d), and 63.7298(a) through (e) for capture systems and control devices applied to pushing emissions, battery stacks, HNR HRSG main stacks, and HNR HRSG bypass/waste heat stacks, respectively.
-
(a) If you have an existing affected source, you must comply with each emission limitation, work practice standard, and operation and maintenance requirement in this subpart that applies to you no later than April 14, 2006. This paragraph does not apply to the emission limitations listed in §§ 63.7290(b) through (d), 63.7296(c) through (f), 63.7297(a) through (d), and 63.7298(a) through (e) for capture systems and control devices applied to pushing emissions, battery stacks, HNR HRSG main stacks, and HNR HRSG bypass/waste heat stacks, respectively.
-
(1) Section 63.7290(a) through (e) for emissions of particulate matter, mercury, total acid gases, HCN, and total PAH from a control device applied to pushing emissions that applies to you within 180 calendar days after the compliance date that is specified in § 63.7283.
-
(b) For each source subject to emission limits in §§ 63.7290(b) through (d), 63.7296(c) through (f), 63.7297(a) through (d), and 63.7298(a) through (e) for capture systems and control devices applied to pushing emissions, battery stacks, HNR HRSG main stacks, and HNR HRSG bypass/waste heat stacks sources, respectively, you must conduct subsequent performance tests once every five years.
-
(b) For each control device applied to pushing emissions and subject to the emission limits in § 63.7290(b) through (e), you must demonstrate continuous compliance by meeting the requirements in paragraphs (b)(1) through (5) of this section:(1) Maintaining emissions of mercury at or below the applicable limits in § 63.7290(b);(2) Maintaining emissions of total acid gases at or below the applicable limits in § 63.7290(c);(3) Maintaining emissions of hydrogen cyanide at or below the applicable limits in § 63.7290(d);(4) Maintaining emissions of total PAHs at or below the applicable limits in § 63.7290(e); and
Citations to §63.7290(e)
-
(1) Section 63.7290(a) through (e) for emissions of particulate matter, mercury, total acid gases, HCN, and total PAH from a control device applied to pushing emissions that applies to you within 180 calendar days after the compliance date that is specified in § 63.7283.
-
(1) Determine the concentration of total PAH, the sum of 17 PAH compounds listed at § 63.7290(e), according to the following test methods.(ii) Method 23 in appendix A-7 to 40 CFR part 60, to determine the concentration of total PAH in the stack gas.
-
(b) For each control device applied to pushing emissions and subject to the emission limits in § 63.7290(b) through (e), you must demonstrate continuous compliance by meeting the requirements in paragraphs (b)(1) through (5) of this section:(1) Maintaining emissions of mercury at or below the applicable limits in § 63.7290(b);(2) Maintaining emissions of total acid gases at or below the applicable limits in § 63.7290(c);(3) Maintaining emissions of hydrogen cyanide at or below the applicable limits in § 63.7290(d);(4) Maintaining emissions of total PAHs at or below the applicable limits in § 63.7290(e); and
Citations to §63.7290(f)(1)
-
(f) You must meet each operating limit in paragraphs (f)(1) through (4) of this section that applies to you for a new or existing coke oven battery.(1) For each venturi scrubber applied to pushing emissions, you must maintain the daily average pressure drop and scrubber water flow rate at or above the minimum levels established during the initial performance test.(2) For each hot water scrubber applied to pushing emissions, you must maintain the daily average water pressure and water temperature at or above the minimum levels established during the initial performance test.(3) For each capture system applied to pushing emissions, you must maintain the daily average volumetric flow rate at the inlet of the control device at or above the minimum level established during the initial performance test; or(i) For each capture system that uses an electric motor to drive the fan, you must maintain the daily average fan motor amperes at or above the minimum level established during the initial performance test; and(ii) For each capture system that does not use a fan driven by an electric motor, you must maintain the daily average static pressure at the inlet to the control device at an equal or greater vacuum than the level established during the initial performance test or maintain the daily average fan revolutions per minute (RPM) at or above the minimum level established during the initial performance test.(4) For each multicyclone, you must maintain the daily average pressure drop at or below the minimum level established during the initial performance test.
-
(c) For each venturi scrubber applied to pushing emissions and subject to the operating limits in § 63.7290(f)(1), you must demonstrate continuous compliance by meeting the requirements in paragraphs (c)(1) through (3) of this section.(1) Maintaining the daily average pressure drop and scrubber water flow rate at levels no lower than those established during the initial or subsequent performance test.(2) Operating and maintaining each CPMS according to § 63.7331(b) and recording all information needed to document conformance with these requirements.(3) Collecting and reducing monitoring data for pressure drop and scrubber water flow rate according to § 63.7331(e)(1) through (3).
Citations to §63.7290(f)(2)
-
(f) You must meet each operating limit in paragraphs (f)(1) through (4) of this section that applies to you for a new or existing coke oven battery.(1) For each venturi scrubber applied to pushing emissions, you must maintain the daily average pressure drop and scrubber water flow rate at or above the minimum levels established during the initial performance test.(2) For each hot water scrubber applied to pushing emissions, you must maintain the daily average water pressure and water temperature at or above the minimum levels established during the initial performance test.(3) For each capture system applied to pushing emissions, you must maintain the daily average volumetric flow rate at the inlet of the control device at or above the minimum level established during the initial performance test; or(i) For each capture system that uses an electric motor to drive the fan, you must maintain the daily average fan motor amperes at or above the minimum level established during the initial performance test; and(ii) For each capture system that does not use a fan driven by an electric motor, you must maintain the daily average static pressure at the inlet to the control device at an equal or greater vacuum than the level established during the initial performance test or maintain the daily average fan revolutions per minute (RPM) at or above the minimum level established during the initial performance test.(4) For each multicyclone, you must maintain the daily average pressure drop at or below the minimum level established during the initial performance test.
-
(d) For each hot water scrubber applied to pushing emissions and subject to the operating limits in § 63.7290(f)(2), you must demonstrate continuous compliance by meeting the requirements in paragraphs (d)(1) through (3) of this section.(1) Maintaining the daily average water pressure and temperature at levels no lower than those established during the initial or subsequent performance test.(2) Operating and maintaining each CPMS according to § 63.7331(b) and recording all information needed to document conformance with these requirements.(3) Collecting and reducing monitoring data for water pressure and temperature according to § 63.7331(f).
Citations to §63.7290(f)(3)
-
(f) You must meet each operating limit in paragraphs (f)(1) through (4) of this section that applies to you for a new or existing coke oven battery.(1) For each venturi scrubber applied to pushing emissions, you must maintain the daily average pressure drop and scrubber water flow rate at or above the minimum levels established during the initial performance test.(2) For each hot water scrubber applied to pushing emissions, you must maintain the daily average water pressure and water temperature at or above the minimum levels established during the initial performance test.(3) For each capture system applied to pushing emissions, you must maintain the daily average volumetric flow rate at the inlet of the control device at or above the minimum level established during the initial performance test; or(i) For each capture system that uses an electric motor to drive the fan, you must maintain the daily average fan motor amperes at or above the minimum level established during the initial performance test; and(ii) For each capture system that does not use a fan driven by an electric motor, you must maintain the daily average static pressure at the inlet to the control device at an equal or greater vacuum than the level established during the initial performance test or maintain the daily average fan revolutions per minute (RPM) at or above the minimum level established during the initial performance test.(4) For each multicyclone, you must maintain the daily average pressure drop at or below the minimum level established during the initial performance test.
-
(1) If you elect the operating limit in § 63.7290(f)(3) for volumetric flow rate, measure and record the total volumetric flow rate at the inlet of the control device during each push sampled for each particulate matter test run. Your operating limit is the lowest volumetric flow rate recorded during any of the three runs that meet the emission limit.
-
(i) If you elect the operating limit in § 63.7290(f)(3) for volumetric flow rate, you have a record of the total volumetric flow rate at the inlet of the control device measured during the performance test in accordance with § 63.7323(c)(1); or
-
(g) If you elect the operating limit in § 63.7290(f)(3) for a capture system applied to pushing emissions, you must install, operate, and maintain a device to measure the total volumetric flow rate at the inlet of the control device.
-
(e) For each capture system applied to pushing emissions and subject to the operating limit in § 63.7290(f)(3), you must demonstrate continuous compliance by meeting the requirements in paragraph (e)(1), (2), or (3) of this section:(1) If you elect the operating limit for volumetric flow rate in § 63.7290(f)(3):(i) Maintaining the daily average volumetric flow rate at the inlet of the control device at or above the minimum level established during the initial or subsequent performance test; and(ii) Checking the volumetric flow rate at least every 8 hours to verify the daily average is at or above the minimum level established during the initial or subsequent performance test and recording the results of each check.(2) If you elect the operating limit for fan motor amperes in § 63.7290(f)(3)(i):(i) Maintaining the daily average fan motor amperages at or above the minimum level established during the initial or subsequent performance test; and(ii) Checking the fan motor amperage at least every 8 hours to verify the daily average is at or above the minimum level established during the initial or subsequent performance test and recording the results of each check.(3) If you elect the operating limit for static pressure or fan RPM in § 63.7290(f)(3)(ii):(i) Maintaining the daily average static pressure at the inlet to the control device at an equal or greater vacuum than established during the initial or subsequent performance test or the daily average fan RPM at or above the minimum level established during the initial or subsequent performance test; and(ii) Checking the static pressure or fan RPM at least every 8 hours to verify the daily average static pressure at the inlet to the control device is at an equal or greater vacuum than established during the initial or subsequent performance test or the daily average fan RPM is at or above the minimum level established during the initial or subsequent performance test and recording the results of each check.
Citations to §63.7290(f)(3)(i)
-
(2) If you elect the operating limit in § 63.7290(f)(3)(i) for fan motor amperes, measure and record the fan motor amperes during each push sampled for each particulate matter test run. Your operating limit is the lowest fan motor amperes recorded during any of the three runs that meet the emission limit.
-
(ii) If you elect the operating limit in § 63.7290(f)(3)(i) for fan motor amperes, you have a record of the fan motor amperes during the performance test in accordance with § 63.7323(c)(2); or
-
(h) If you elect the operating limit in § 63.7290(f)(3)(i) for a capture system applied to pushing emissions, you must install, operate, and maintain a device to measure the fan motor amperes.
-
(2) If you elect the operating limit for fan motor amperes in § 63.7290(f)(3)(i):(i) Maintaining the daily average fan motor amperages at or above the minimum level established during the initial or subsequent performance test; and(ii) Checking the fan motor amperage at least every 8 hours to verify the daily average is at or above the minimum level established during the initial or subsequent performance test and recording the results of each check.
Citations to §63.7290(f)(3)(ii)
-
(3) If you elect the operating limit in § 63.7290(f)(3)(ii) for static pressure or fan RPM, measure and record the static pressure at the inlet of the control device or fan RPM during each push sampled for each particulate matter test run. Your operating limit for static pressure is the minimum vacuum recorded during any of the three runs that meets the emission limit. Your operating limit for fan RPM is the lowest fan RPM recorded during any of the three runs that meets the emission limit.
-
(iii) If you elect the operating limit in § 63.7290(f)(3)(ii) for static pressure or fan RPM, you have a record of the static pressure at the inlet of the control device or fan RPM measured during the performance test in accordance with § 63.7323(c)(3).
-
(i) If you elect the operating limit in § 63.7290(f)(3)(ii) for a capture system applied to pushing emissions, you must install, operate and maintain a device to measure static pressure at the inlet of the control device or the fan RPM.
-
(3) If you elect the operating limit for static pressure or fan RPM in § 63.7290(f)(3)(ii):(i) Maintaining the daily average static pressure at the inlet to the control device at an equal or greater vacuum than established during the initial or subsequent performance test or the daily average fan RPM at or above the minimum level established during the initial or subsequent performance test; and(ii) Checking the static pressure or fan RPM at least every 8 hours to verify the daily average static pressure at the inlet to the control device is at an equal or greater vacuum than established during the initial or subsequent performance test or the daily average fan RPM is at or above the minimum level established during the initial or subsequent performance test and recording the results of each check.
Citations to §63.7290(f)(4)
-
(f) You must meet each operating limit in paragraphs (f)(1) through (4) of this section that applies to you for a new or existing coke oven battery.(1) For each venturi scrubber applied to pushing emissions, you must maintain the daily average pressure drop and scrubber water flow rate at or above the minimum levels established during the initial performance test.(2) For each hot water scrubber applied to pushing emissions, you must maintain the daily average water pressure and water temperature at or above the minimum levels established during the initial performance test.(3) For each capture system applied to pushing emissions, you must maintain the daily average volumetric flow rate at the inlet of the control device at or above the minimum level established during the initial performance test; or(i) For each capture system that uses an electric motor to drive the fan, you must maintain the daily average fan motor amperes at or above the minimum level established during the initial performance test; and(ii) For each capture system that does not use a fan driven by an electric motor, you must maintain the daily average static pressure at the inlet to the control device at an equal or greater vacuum than the level established during the initial performance test or maintain the daily average fan revolutions per minute (RPM) at or above the minimum level established during the initial performance test.(4) For each multicyclone, you must maintain the daily average pressure drop at or below the minimum level established during the initial performance test.
-
(j) For each multicyclone applied to pushing emissions and subject to the operating limit in § 63.7290(f)(4), you must demonstrate compliance by meeting the requirements in paragraphs (j)(1) through (3) of this section.(1) Maintaining the daily average pressure drop at a level at or below the level established during the initial or subsequent performance test.(2) Operating and maintaining each CPMS according to § 63.7331(k) and recording all information needed to document conformance with these requirements.(3) Collecting and reducing monitoring data for pressure drop according to § 63.7331(e)(1) through (3).