§63.606. Performance tests and compliance provisions. — Inbound Citations
40 C.F.R. § 63.606
Statutory Authority
Cited by 10 regulations in release Current.
Citations to 40 U.S.C. § 63.606 as a whole
-
(B) As an alternative to paragraph (d)(1)(ii)(A) of this section, you may establish allowable ranges for the daily averages of the pressure drop across an absorber, or secondary voltage for an electrostatic precipitator, for the purpose of assuring compliance with this subpart using the procedures described in this paragraph. You must establish the allowable ranges based on the baseline average values recorded during previous performance tests, or the results of performance tests conducted specifically for the purposes of this paragraph. You must conduct all performance tests using the methods specified in § 63.606. You must certify that the control devices and processes have not been modified since the date of the performance test from which you obtained the data used to establish the allowable ranges. When a source using the methodology of this paragraph is retested, you must determine new allowable ranges of baseline average values unless the retest indicates no change in the operating parameters outside the previously established ranges.
-
Any affected source subject to the provisions of this subpart is exempted from any otherwise applicable new source performance standard contained in 40 CFR part 60, subpart T, subpart U, or subpart NN. To be exempt, a source must have a current operating permit pursuant to title V of the Clean Air Act and the source must be in compliance with all requirements of this subpart. For each affected source, this exemption is upon the date that you demonstrate to the Administrator that the requirements of §§ 63.605 and 63.606 have been met.
Citations to §63.606(f)
-
(i) 1 Preparation of Sample, IBR approved for § 63.606(f), § 63.626(f).
Citations to §63.606(f)(1)
-
(f) You must determine compliance with the applicable total fluorides standards specified in Tables 1 and 2 to this subpart as specified in paragraphs (f)(1) through (3) of this section.(2) You must use Method 13A or 13B (40 CFR part 60, appendix A) to determine the total fluorides concentration (Ci) and the volumetric flow rate (Qi) of the effluent gas at each emission point. The sampling time for each run at each emission point must be at least 60 minutes. The sampling volume for each run at each emission point must be at least 0.85 dscm (30 dscf). If Method 13B is used, the fusion of the filtered material described in Section 7.3.1.2 and the distillation of suitable aliquots of containers 1 and 2, described in section 7.3.3 and 7.3.4 in Method 13 A, may be omitted.(i) Determine the mass flow rate (Mp) of the phosphorus-bearing feed using the measurement system described in § 63.605(a).(ii) Determine the P2O5 content (Rp) of the feed using, as appropriate, the following methods specified in Methods Used and Adopted By The Association of Florida Phosphate Chemists (incorporated by reference, see § 63.14) where applicable:(A) 1 Preparation of Sample.(B) 3 Phosphorus-P2O5 or Ca3(PO4)2, Method A—Volumetric Method.(C) 3 Phosphorus-P2O5 or Ca3(PO4)2, Method B—Gravimetric Quimociac Method.(D) 3 Phosphorus-P2O5 or Ca3(PO4)2, Method C—Spectrophotometric Method.(E) Section XI, Methods of Analysis for Phosphoric Acid, Superphosphate, Triple Superphosphate, and Ammonium Phosphates, No. 3 Total Phosphorus-P2O5, Method A—Volumetric Method.(F) Section XI, Methods of Analysis for Phosphoric Acid, Superphosphate, Triple Superphosphate, and Ammonium Phosphates, No. 3 Total Phosphorus-P2O5, Method B—Gravimetric Quimociac Method.(G) Section XI, Methods of Analysis for Phosphoric Acid, Superphosphate, Triple Superphosphate, and Ammonium Phosphates, No. 3 Total Phosphorus-P2O5, Method C—Spectrophotometric Method.
Citations to §63.606(f)(2)
-
(f) You must determine compliance with the applicable total fluorides standards specified in Tables 1 and 2 to this subpart as specified in paragraphs (f)(1) through (3) of this section.(2) You must use Method 13A or 13B (40 CFR part 60, appendix A) to determine the total fluorides concentration (Ci) and the volumetric flow rate (Qi) of the effluent gas at each emission point. The sampling time for each run at each emission point must be at least 60 minutes. The sampling volume for each run at each emission point must be at least 0.85 dscm (30 dscf). If Method 13B is used, the fusion of the filtered material described in Section 7.3.1.2 and the distillation of suitable aliquots of containers 1 and 2, described in section 7.3.3 and 7.3.4 in Method 13 A, may be omitted.(i) Determine the mass flow rate (Mp) of the phosphorus-bearing feed using the measurement system described in § 63.605(a).(ii) Determine the P2O5 content (Rp) of the feed using, as appropriate, the following methods specified in Methods Used and Adopted By The Association of Florida Phosphate Chemists (incorporated by reference, see § 63.14) where applicable:(A) 1 Preparation of Sample.(B) 3 Phosphorus-P2O5 or Ca3(PO4)2, Method A—Volumetric Method.(C) 3 Phosphorus-P2O5 or Ca3(PO4)2, Method B—Gravimetric Quimociac Method.(D) 3 Phosphorus-P2O5 or Ca3(PO4)2, Method C—Spectrophotometric Method.(E) Section XI, Methods of Analysis for Phosphoric Acid, Superphosphate, Triple Superphosphate, and Ammonium Phosphates, No. 3 Total Phosphorus-P2O5, Method A—Volumetric Method.(F) Section XI, Methods of Analysis for Phosphoric Acid, Superphosphate, Triple Superphosphate, and Ammonium Phosphates, No. 3 Total Phosphorus-P2O5, Method B—Gravimetric Quimociac Method.(G) Section XI, Methods of Analysis for Phosphoric Acid, Superphosphate, Triple Superphosphate, and Ammonium Phosphates, No. 3 Total Phosphorus-P2O5, Method C—Spectrophotometric Method.
Citations to §63.606(f)(3)
-
(2) Calculate the equivalent P2O5 feed by determining the total mass rate, in metric ton/hour of phosphorus bearing feed, using the monitoring system specified in paragraph (a)(1) of this section and the procedures specified in § 63.606(f)(3).
-
(f) You must determine compliance with the applicable total fluorides standards specified in Tables 1 and 2 to this subpart as specified in paragraphs (f)(1) through (3) of this section.(2) You must use Method 13A or 13B (40 CFR part 60, appendix A) to determine the total fluorides concentration (Ci) and the volumetric flow rate (Qi) of the effluent gas at each emission point. The sampling time for each run at each emission point must be at least 60 minutes. The sampling volume for each run at each emission point must be at least 0.85 dscm (30 dscf). If Method 13B is used, the fusion of the filtered material described in Section 7.3.1.2 and the distillation of suitable aliquots of containers 1 and 2, described in section 7.3.3 and 7.3.4 in Method 13 A, may be omitted.(i) Determine the mass flow rate (Mp) of the phosphorus-bearing feed using the measurement system described in § 63.605(a).(ii) Determine the P2O5 content (Rp) of the feed using, as appropriate, the following methods specified in Methods Used and Adopted By The Association of Florida Phosphate Chemists (incorporated by reference, see § 63.14) where applicable:(A) 1 Preparation of Sample.(B) 3 Phosphorus-P2O5 or Ca3(PO4)2, Method A—Volumetric Method.(C) 3 Phosphorus-P2O5 or Ca3(PO4)2, Method B—Gravimetric Quimociac Method.(D) 3 Phosphorus-P2O5 or Ca3(PO4)2, Method C—Spectrophotometric Method.(E) Section XI, Methods of Analysis for Phosphoric Acid, Superphosphate, Triple Superphosphate, and Ammonium Phosphates, No. 3 Total Phosphorus-P2O5, Method A—Volumetric Method.(F) Section XI, Methods of Analysis for Phosphoric Acid, Superphosphate, Triple Superphosphate, and Ammonium Phosphates, No. 3 Total Phosphorus-P2O5, Method B—Gravimetric Quimociac Method.(G) Section XI, Methods of Analysis for Phosphoric Acid, Superphosphate, Triple Superphosphate, and Ammonium Phosphates, No. 3 Total Phosphorus-P2O5, Method C—Spectrophotometric Method.
Citations to §63.606(g)(1)
-
(g) You must demonstrate compliance with the applicable particulate matter standards specified in Tables 1 and 2 to this subpart as specified in paragraphs (g)(1) through (3) of this section.(2) Use Method 5 at 40 CFR part 60, appendix A-3 to determine the particulate matter concentration (C) and volumetric flow rate (Q) of the effluent gas. Except as specified in paragraph (h) of this section, the sampling time and sample volume for each run must be at least 60 minutes and 0.85 dry standard cubic meter (30 dry standard cubic feet).(3) Use the CMS described in § 63.605(b) to determine the phosphate rock feed rate (P) for each run.
Citations to §63.606(g)(2)
-
(g) You must demonstrate compliance with the applicable particulate matter standards specified in Tables 1 and 2 to this subpart as specified in paragraphs (g)(1) through (3) of this section.(2) Use Method 5 at 40 CFR part 60, appendix A-3 to determine the particulate matter concentration (C) and volumetric flow rate (Q) of the effluent gas. Except as specified in paragraph (h) of this section, the sampling time and sample volume for each run must be at least 60 minutes and 0.85 dry standard cubic meter (30 dry standard cubic feet).(3) Use the CMS described in § 63.605(b) to determine the phosphate rock feed rate (P) for each run.
Citations to §63.606(g)(3)
-
(g) You must demonstrate compliance with the applicable particulate matter standards specified in Tables 1 and 2 to this subpart as specified in paragraphs (g)(1) through (3) of this section.(2) Use Method 5 at 40 CFR part 60, appendix A-3 to determine the particulate matter concentration (C) and volumetric flow rate (Q) of the effluent gas. Except as specified in paragraph (h) of this section, the sampling time and sample volume for each run must be at least 60 minutes and 0.85 dry standard cubic meter (30 dry standard cubic feet).(3) Use the CMS described in § 63.605(b) to determine the phosphate rock feed rate (P) for each run.